Fault Analysis of Stator Inter-Turn Short Circuit in Doubly Fed Induction Machines

2014 ◽  
Vol 912-914 ◽  
pp. 679-683
Author(s):  
Bo Qiang Xu ◽  
Jing Ting Wang

The doubly fed induction generator (DFIG) is an important component of wind turbine systems,so the fault analysis is great necessary.This paper shows a way to analysis the features of stator inter-short circuit fault,which is based on multi-circuit theory.The fault features of stator inter-turn short circuit in doubly fed induction are analyzed in this paper,deeply and thoroughly.Then a multi-loop model was carried out to simulate 5.5kW DFIG ,which was in normal conditions and in cases of fault of stator inter-turn short circuit,respectively.A fourier transformation was applied to analysis the simulation results,especially about short circuit current.

2021 ◽  
Vol 15 (1) ◽  
pp. 37-44
Author(s):  
Thai Hiep Le ◽  
◽  
Duong Hoang Phuc Tran

In this paper, the operating mode of a doubly fed induction generator (DFIG) wind turbine is studied in order to evaluate its fault ride-through and transient stability with a grid’s short circuit fault at near the wind power plant. Based on the structure of DFIG, external resistors are directly connected to rotor windings, then the generator operates as a wound rotor induction generator (WRIG) when there is a short circuit fault on the grid. According to the simulation results in Matlab, the active power is consumed on the crowbar resistor, causing the active power characteristic of generator is changed from high to low. As a result, the amount of excess mechanical energy is not much, so the generator be not accelerated significantly. These simulation results show that it is appropriate to use the crowbar resistor to change the power characteristic of the DFIG. Thanks to this change, the generator is still connected to the grid, stable operation both during and after a short circuit.


2012 ◽  
Vol 512-515 ◽  
pp. 782-787
Author(s):  
Jia Jun Zhai ◽  
Bu Han Zhang ◽  
Kui Wang ◽  
Wen Shao ◽  
Cheng Xiong Mao

Doubly fed induction generator (DFIG) is now becoming one of most widely used wind turbines in global market for wind power generation, due to its outstanding advantages. However, the DFIG is sensitive to grid faults. The DFIG will have to be removed from the grid if there’s no protection appliance in it. Therefore, the crowbar protection is widely used in the world for improving the low voltage ride-through ability of wind turbines. This paper analysed the operating characteristics and short-circuit current of DFIG under symmetrical short-circuit fault with respect to different sags to grid voltage, which on the basis of DFIG wind turbine with crowbar protection. And the expressions of short-circuit current under symmetrical short-circuit fault for DFIG were derived. The effectiveness of the expression was simulated in PSCAD/EMTDC.


Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2471 ◽  
Author(s):  
Jing Li ◽  
Tao Zheng ◽  
Zengping Wang

An accurate calculation of short-circuit current (SCC) is very important for relay protection setting and optimization design of electrical equipment. The short-circuit current for a doubly-fed induction generator wind turbine (DFIG-WT) under excitation regulation of a converter contains the stator current and grid-side converter (GSC) current. The transient characteristics of GSC current are controlled by double closed-loops of the converter and influenced by fluctuations of direct current (DC) bus voltage, which is characterized as high order, multiple variables, and strong coupling, resulting in great difficulty with analysis. Existing studies are mainly focused on the stator current, neglecting or only considering the steady-state short-circuit current of GSC, resulting in errors in the short-circuit calculation of DFIG-WT. This paper constructs a DFIG-WT total current analytical model involving GSC current. Based on Fourier decomposition of switch functions and the frequency domain analytical method, the fluctuation of DC bus voltage is considered and described in detail. With the proposed DFIG-WT short-circuit current analytical model, the generation mechanism and evolution law of harmonic components are revealed quantitatively, especially the second harmonic component, which has a great influence on transformer protection. The accuracies of the theoretical analysis and mathematical model are verified by comparing calculation results with simulation results and low-voltage ride-through (LVRT) field test data of a real DFIG.


2021 ◽  
Vol 9 ◽  
Author(s):  
Jun Yin

With the enlarging scale of a doubly fed induction generator (DFIG) connected to a power system, the influence of short-circuit current on the system relay protection could not be ignored. Setting and configuring relay protection would be affected by an imprecise short-circuit current calculation. However, some existing studies only consider the condition that the input is the Crowbar and the rotor excitation is blocked. China's new network standard requires the output reactive support current of a DFIG and will change the characteristics of short-circuit current. To solve this problem, on the basis of analyzing the characters of the transient equivalent potential of a DFIG, the transient model of a DFIG with uninterrupted excitation is provided. Based on the characteristics of a non-abrupt change of flux linkage and the requirement of a new grid standard reactive support current, the short-circuit current calculation method of a DFIG with uninterrupted excitation is put forward. Based on the real-time digital simulator (RTDS), a digital-analog experimental platform containing the actual control unit of the DFIG converter is founded, the proposed short-circuit current root mean square (RMS) value calculating method is validated.