The Analysis of the Effect of Fouling on the Performance of the Fill Layer

2014 ◽  
Vol 986-987 ◽  
pp. 998-1003
Author(s):  
Lu Ping Bai ◽  
Li Zhang ◽  
Xiao Feng Lu

Based on that the film filling was simplified to the flat plate model, the heat and mass transfer of the filling zone with fouling in cooling tower were analyzed. The effect of fouling on the performance of filler was analyzed according to the dirt growth model. The work done in this paper can simply forecast changes in cooling tower performance caused by the filler fouling. It will lay a theoretical foundation for accurately calculating the performance coefficient of filler. And it is helpful to solving the problem of no the ripe empirical formula of filler performance with fouling for engineering applications.

2020 ◽  
Vol 14 (1) ◽  
pp. 25
Author(s):  
Abdul Aziz Rohman Hakim ◽  
Engkos Achmad Kosasih

This paper discusses heat and mass transfer in cooling tower fill. In this research, dry bulb temperature at the bottom fill, ambient relative humidity, air stream velocity entering fill, dry bulb temperature leaving the fill, relative humidity of air leaving the fill, inlet and outlet water temperature of cooling tower were measured. Those data used in heat and mass transfer calculation in cooling tower fill. Then, do the heat and mass transfer calculation based on proposed approch. The results are compared with design data. The design and analogy method showed different  result. The parameter which influence the heat transfer at cooling tower are represented by coefficient of heat transfer hl and coefficient of mass transfer k­l. The differencies result between design and analogy method shows that there is important parameter which different. Deeply study needed for it.


1997 ◽  
Vol 38 (10-13) ◽  
pp. 1209-1218 ◽  
Author(s):  
Shigeru Mori ◽  
Mikio Kumita ◽  
Tohru Takahashi ◽  
Akira Tanimoto ◽  
Mikio Sakakibara

Author(s):  
Aleksandr Pushnov ◽  
Algirdas Sakalauskas

A new efficient ceramic regular sedimentation for heat and mass transfer in apparatuses of environmental protection is proposed. A new sedimentation realization with isotropic properties of a structure is offered. The aerodynamic test results of the new sedimentation are shown. The paper describes a laboratory test facility designed for conducting aerodynamic investigation of cooling tower sedimentation. Measured parameters, data processing techniques and examples of the results obtained are discussed. The tested sedimentation is a porous layer of ceramic foam manufactured by special technology. Santrauka Siūloma nauja keraminių reguliarių antgalių dinamika šilumos ir masės pernašos procesams aplinkos apsaugos įrenginiuose vykdyti. Siūlomas antgalis leis realizuoti poringojo sluoksnio izotopinę struktūrą. Pateikti naujo antgalio aerodinaminių bandymų rezultatai. Резюме Предложена новая эффективная керамическая регулярная насадка для осуществления процессов тепло- и массообмена в аппаратах газоочистки. Предлагаемая насадка позволяет реализовать изотропную структуру зернистого слоя. Приведены результаты аэродинамических испытаний новой насадки.