Stress Distribution in an Artificial Cruciate Ligament during the Gait Cycle

2014 ◽  
Vol 601 ◽  
pp. 167-170
Author(s):  
Lucian Bogdan ◽  
Cristian Sorin Nes ◽  
Angelica Enkelhardt ◽  
Nicolae Faur ◽  
Carmen Sticlaru ◽  
...  

This paper presents a finite element analysis in order to determinate the stress distribution in an proposed model of the artificial cruciate ligament of the knee joint during the gait cycle.

Author(s):  
Zahra Trad ◽  
Abdelwahed Barkaoui ◽  
Moez Chafra ◽  
João Manuel RS Tavares

Osteoarthritis is a globally common disease that imposes a considerable ongoing health and economic burden on the socioeconomic system. As more and more biomechanical factors have been explored, malalignment of the lower limb has been found to influence the load distribution across the articular surface of the knee joint substantially. In this work, a three-dimensional finite element analysis was carried out to investigate the effect of varying the high tibial osteotomy correction angle on the stress distribution in both compartments of the human knee joint. Thereafter, determine the optimal correction angle to achieve a balanced loading between these two compartments. The developed finite element model was validated against experimental and numerical results. The findings of this work suggest that by changing the correction angle from 0° to 10° valgus, high tibial osteotomy shifted the mechanical load from the affected medial compartment to the lateral compartment with intact cartilage. The Von Mises and the shear stresses decreased in the medial compartment and increased in the lateral compartment. Moreover, a balanced stress distribution between the two compartments as well as the desired alignment were achieved under a valgus hypercorrection of 4.5° that significantly unloads the medial compartment, loads the lateral compartment and arrests the progression of osteoarthritis. After comparing the achieved results against the ones of previous studies that explored the effects of the high tibial osteotomy correction angle on either clinical outcomes or biomechanical outcomes, one can conclude that the findings of this study agree well with the related clinical data and recommendations found in the literature.


2021 ◽  
Vol 11 (3) ◽  
pp. 1220
Author(s):  
Azeem Ul Yaqin Syed ◽  
Dinesh Rokaya ◽  
Shirin Shahrbaf ◽  
Nicolas Martin

The effect of a restored machined hybrid dental ceramic crown–tooth complex is not well understood. This study was conducted to determine the effect of the stress state of the machined hybrid dental ceramic crown using three-dimensional finite element analysis. Human premolars were prepared to receive full coverage crowns and restored with machined hybrid dental ceramic crowns using the resin cement. Then, the teeth were digitized using micro-computed tomography and the teeth were scanned with an optical intraoral scanner using an intraoral scanner. Three-dimensional digital models were generated using an interactive image processing software for the restored tooth complex. The generated models were imported into a finite element analysis software with all degrees of freedom concentrated on the outer surface of the root of the crown–tooth complex. To simulate average occlusal load subjected on a premolar a total load of 300 N was applied, 150 N at a buccal incline of the palatal cusp, and palatal incline of the buccal cusp. The von Mises stresses were calculated for the crown–tooth complex under simulated load application was determined. Three-dimensional finite element analysis showed that the stress distribution was more in the dentine and least in the cement. For the cement layer, the stresses were more concentrated on the buccal cusp tip. In dentine, stress was more on the cusp tips and coronal 1/3 of the root surface. The conventional crown preparation is a suitable option for machined polymer crowns with less stress distribution within the crown–tooth complex and can be a good aesthetic replacement in the posterior region. Enamic crowns are a good viable option in the posterior region.