Influences of Glassified Micro-Bubble on Mechanical Properties of Ultra-High-Strength Concrete after Exposure to High Temperature

2014 ◽  
Vol 629-630 ◽  
pp. 259-264
Author(s):  
Gai Fei Peng ◽  
Xiao Li Wang ◽  
Lin Wang

An experimental investigation was conducted to study residual mechanical properties of Ultra-High-Strength concrete with different dosages of glassified micro-bubble after exposure to high temperature. After exposure to different target temperatures (room temperature, 200 °C, 400 °C, 600 °C,800 °C), residual mechanical properties (residual compressive strength, residual tensile splitting strength, residual fracture energy) of Ultra-High-Strength concrete under different conditions including 1 water-binder ratios (0.18), 3 different contents of glassified micro-bubble (0%, 40%, 60%) were all investigated. The effect of different dosage of glassified micro-bubble was studied on residual mechanical properties of Ultra-High-Strength concrete after exposure to high temperature. The results indicate that the variations of different kinds of Ultra-High-Strength concrete with different dosage of glassified micro-bubble are basically the same. With the increase of temperature, the residual mechanical properties increase at first, then decrease. The residual mechanical properties decrease after exposure to high temperature of 800 °C.

2014 ◽  
Vol 1014 ◽  
pp. 49-52
Author(s):  
Xiao Ping Su

With the wide application of high strength concrete in the building construction,the risk making concrete subject to high temperatures during a fire is increasing. Comparison tests on the mechanical properties of high strength concrete (HSC) and normal strength concrete (NSC) after the action of high temperature were made in this article, which were compared from the following aspects: the peak stress, the peak strain, elasticity modulus, and stress-strain curve after high temperature. Results show that the laws of the mechanical properties of HSC and NSC changing with the temperature are the same. With the increase of heating temperature, the peak stress and elasticity modulus decreases, while the peak strain grows rapidly. HSC shows greater brittleness and worse fire-resistant performance than NSC, and destroys suddenly. The research and evaluation on the fire-resistant performance of HSC should be strengthened during the structural design and construction on the HSC buildings.


2019 ◽  
Vol 218 ◽  
pp. 448-456 ◽  
Author(s):  
Gyeongcheol Choe ◽  
Gyuyong Kim ◽  
Hongseop Kim ◽  
Euichul Hwang ◽  
Sangkyu Lee ◽  
...  

2021 ◽  
Vol 12 (1) ◽  
pp. 30
Author(s):  
Mohamed Amin ◽  
Khaled Abu el-hassan

The effects of the types of fibers on mechanical properties of normal and high strength concrete under high temperature, up to 700 °C, was investigated. Three different- type fiber; "Steel Fiber (SF), Glass Fiber (GF) and Polypropylene Fiber (PPF)" are added into the concretes in five different ratios (0, 0.50, 1.00, 1.50 and 2.0%)of the volume under the following temperatures; 22, 100, 400 and 700°C. The results indicate that all the different types of fibers researched contribute to both the compressive and flexural strengths of concrete under high temperature, however, it is also found that this contribution decreases with an increase in temperature. The flexural strengths and compressive strengths for NSC and HSC mixes at 28 days under high temperature decreases as the temperature increases especially up to 400°C. Also, the best compressive and flexural strengths performance under high temperature was also those of SF. The compressive strength of the concrete incorporating SF was reduced under high temperature only, while the mixes containing PPF and GF were reduced under high temperature or with fiber addition. The optimum fiber addition ratios of the mixes containing PPF and GF are between 0.5-1.0 percent by volume. And for SF, it is 1.5% by the volume.


Sign in / Sign up

Export Citation Format

Share Document