Determination of Damage to the Piezoelectric Sensor by Measuring the Electrical Capacitance

2015 ◽  
Vol 240 ◽  
pp. 31-35
Author(s):  
Witold Rządkowski ◽  
Paweł Pyrzanowski

This work presents testing mechanical defects of MFC piezoelectric transducers. The issue is important when piezoelectric transducer is used as eg. strain sensor. Repeatability of measurements is a goal, which can be obtained only if transducer has the same physical properties in every measurement. One way to determine damaged part of the sensor is measuring capacitance of MFC transducer. A couple of tests were performed to determine capacitance under non-destroying cyclic loading, and with loads causing PZT failure. Relation of capacity and load level was also investigated. All tests were validated with results from traditional resistive strain gauge

Author(s):  
O. G. Bondarenko

The conditions for the emission of acoustic energy into the pipeline environment and the reception of reflected signals from inconsistencies in dry acoustic contact cause certain dimensions of the actual contact area between the transducers and the pipe surface. The basic approaches to the determination of the actual area of ​​dry acoustic contact between the surfaces of the piezoelectric transducer and the pipe are formulated under the influence of constant static force of pressing the surfaces in low-frequency flaw detection using ultrasonic directional waves. Expressions have been proposed to determine the area of ​​actual acoustic contact for single and numerical micro projections of the pipe surface. The principle of quality control of balancing of acoustic antenna piezoelectric transducers in modern systems of low-frequency diagnostics of the technical state of longitudinal pipelines by ultrasonic directed waves is described. It is revealed that after correct balancing of all the acoustic antenna piezoelectric transducers, the column image does not appear on the display screen and the mathematical support of the system will automatically collect the technical status of the diagnosed section of the pipeline, the results of which are displayed on the display screen. It is established that the actual area of ​​dry acoustic contact in the "piezoelectric product" system in low-frequency defectoscopy depends on the magnitude of the static force of pressing the surface of the piezoelectric transducer to the surface of the product. It is revealed that the deformation of the micro protrusions of the surface of the product under the action of static clamping force is uneven, which does not allow to fully calculate the actual area of ​​dry contact by mathematical methods. It is shown that in modern systems of low-frequency ultrasonic diagnostics of extended pipelines, directional waves control the quality of dry contact of the surface of the piezoelectric transducer with the surface of the pipe by balancing acoustic antennas with the use of special test programs.


Author(s):  
Nik Ahmad Zainal Abidin ◽  
◽  
Norkharziana Mohd Nayan ◽  
Azuwa Ali ◽  
N. A. Azli ◽  
...  

This research presents a simulation analysis for the AC-DC converter circuit with a different configurations of the array connection of the piezoelectric sensor. The selection of AC-DC converter circuits is full wave bridge rectifier (FWBR), parallel SSHI (P-SSHI) and parallel voltage multiplier (PVM) with array configuration variation in series (S), parallel (P), series-parallel (SP) and parallel-series (PS). The system optimizes with different load configurations ranging from 10 kΩ to 1 MΩ. The best configuration of AC-DC converter with an appropriate array piezoelectric connection producing the optimum output of harvested power is presented. According to the simulation results, the harvested power produced by using P-SSHI converter connected with 3 parallel piezoelectric transducer array was 85.9% higher than for PVM and 15.88% higher than FWBR.


Sign in / Sign up

Export Citation Format

Share Document