The Accuracy of Lower Extremity Alignment in Total Knee Arthroplasty Using Navigation System - Data Analysis of 661 Cases -

2009 ◽  
Vol 44 (6) ◽  
pp. 599 ◽  
Author(s):  
Soon-Haeng Kwon ◽  
Joo-Hong Lee ◽  
Kwang-Kyoun Kim
Author(s):  
Hideki Mizu-uchi ◽  
Hidehiko Kido ◽  
Tomonao Chikama ◽  
Kenta Kamo ◽  
Satoshi Kido ◽  
...  

AbstractThe optimal placement within 3 degrees in coronal alignment was reportedly achieved in only 60 to 80% of patients when using an extramedullary alignment guide for the tibial side in total knee arthroplasty (TKA). This probably occurs because the extramedullary alignment guide is easily affected by the position of the ankle joint which is difficult to define by tibial torsion. Rotational direction of distal end of the extramedullary guide should be aligned to the anteroposterior (AP) axis of the proximal tibia to acquire optimal coronal alignment in the computer simulation studies; however, its efficacy has not been proven in a clinical setting. The distal end of the guide can be overly displaced from the ideal position when using a conventional guide system despite the alignment of the AP axis to the proximal tibia. This study investigated the effect of displacement of the distal end of extramedullary guide relative to the tibial coronal alignment while adjusting the rotational alignment of the distal end to the AP axis of the proximal tibia in TKA. A total of 50 TKAs performed in 50 varus osteoarthritic knees using an image-free navigation system were included in this study. The rotational alignment of the proximal side of the guide was adjusted to the AP axis of the proximal tibia. The position of the distal end of the guide was aligned to the center of the ankle joint as viewed from the proximal AP axis (ideal position) and as determined by the navigation system. The tibial intraoperative coronal alignments were recorded as the distal end was moved from the ideal position at 3-mm intervals. The intraoperative alignments were 0.5, 0.9, and 1.4 degrees in valgus alignment with 3-, 6-, and 9-mm medial displacements, respectively. The intraoperative alignments were 0.7, 1.2, and 1.7 degrees in varus alignment with 3-, 6-, and 9-mm lateral displacements, respectively. In conclusion, the acceptable tibial coronal alignment (within 2 degrees from the optimal alignment) can be achieved, although some displacement of the distal end from the ideal position can occur after the rotational alignment of the distal end of the guide is adjusted to the AP axis of the proximal tibia.


Author(s):  
Pablo Besa ◽  
Rafael Vega ◽  
Gerardo Ledermann ◽  
Claudio Calvo ◽  
Manuela Angulo ◽  
...  

AbstractThis study aimed to determine the tibial cut (TC) accuracy using extensor hallucis longus (EHL) tendon as an anatomical landmark to position the total knee arthroplasty (TKA) extramedullary tibial guide (EMTG), and its impact on the TKA mechanical alignment (MA). We retrospectively studied 96 TKA, performed by a single surgeon, using a femoral tailored intramedullary guide technique. Seventeen were prior to the use of the EHL and 79 used the EHL tendon to position the EMTG. We analyzed preoperative and postoperative standing total lower extremity radiographs to determine the tibial component angle (TCA) and the correction in MA, comparing pre-EHL use and post-EHL technique incorporation. Mean TCA was 88.89 degrees and postoperative MA was neutral in 81% of patients. Pre- and postoperative MAs were not correlated. As a conclusion of this study, using the EHL provides a safe and easy way to determine the position of EMTG.


Author(s):  
Masanori Tsubosaka ◽  
Tomoyuki Kamenaga ◽  
Yuichi Kuroda ◽  
Koji Takayama ◽  
Shingo Hashimoto ◽  
...  

AbstractSeveral studies have reported better clinical outcomes following kinematically aligned total knee arthroplasty (KA-TKA) than mechanically aligned TKA. Consistent reproduction of a KA-TKA is aided by accurate tibial bone resections using computer navigation systems. This study compares an accelerometer-based portable navigation system with a conventional navigation system on tibial bone resection and clinical outcomes in KA-TKA. This study included 60 knees of patients who underwent primary KA-TKA between May 2015 and September 2017. They were randomly assigned to the OrthoPilot and iASSIST groups. A tibial bone cut was performed with 3 degree varus and 7 degree posterior slope in relation to the mechanical axis in all cases. The tibial component angle (TCA) and posterior slope angle (PSA) were evaluated by postoperative radiography, and those that deviated more than 2 degree were set as outliers. The clinical outcomes were the knee range of motion (ROM) and 2011 Knee Society Score (KSS) evaluated at 1 year postoperation. The groups were compared in terms of the TCA, PSA, number of outliers, ROM, and 2011 KSS (p < 0.05). No significant difference was observed between the groups in terms of the mean TCA, PSA, number of outliers, ROM, and categories of the 2011 KSS (objective knee indicators, symptoms, satisfaction, expectations, and functional activities). Although tibial bone cuts were performed with 3 degree varus and 7 degree posterior slope, no significant difference was observed between the OrthoPilot and iASSIST groups in terms of the accuracy of cuts or postoperative clinical result. The iASSIST was found to be a simple and useful navigation system for KA-TKA.


2014 ◽  
Vol 29 (7) ◽  
pp. 1388-1393 ◽  
Author(s):  
David A.J. Wilson ◽  
Janie L. Astephen Wilson ◽  
Glen Richardson ◽  
Michael J. Dunbar

2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 1932.1-1933
Author(s):  
M. Eymir ◽  
E. Yuksel ◽  
B. Unver ◽  
K. Sevik ◽  
V. Karatosun

Background:Patients with TKA show impairments in standing balance up to 1 year after surgery. The impaired standing balance in TKA patients was found to be associated with falls risk and decreased functional level. Assessing of standing balance with objective and reliable assessments tools would therefore be extremely useful for determining accurate exercise program, and risks of falling, especially during the rehabilitative period when ambulation is at its most unsteady (1, 2). The stepping maneuver requires adequate strength and motor control to stabilize the body over the stance limb while the other leg is stepping, therefore the Step Test (ST) provides significant information for dynamic standing balance and lower limb motor control (3). The reliability of ST is reported in patient groups such as stroke, however, there is not any study that investigates the reliability of ST in patients with TKA in the current literature.Objectives:The purposes of this study were to determine the test-retest reliability and the minimal detectable change (MDC) of the ST in patients with TKA.Methods:40 patients with TKA due to knee osteoarthritis, operated by the same surgeon, were included in this study. Patients performed trials for ST twice on the same day. Between the first and second trials, patients waited for an hour on sitting position to prevent fatigue. The ST assesses an individual’s ability to place one foot onto a 7.5-cm-high step and then back down to the floor repeatedly as fast as possible for 15 seconds. The score is the number of steps completed in the 15-second period for each lower extremity. Scores for each lower extremity were recorded separately. Prior to the testing, the ST was demonstrated by the tester and all participants were allowed to a practice trial.Results:The ST showed an excellent test-retest reliability (ICC2,1=0.95) in this study. Standard error of measurement (SEM) and MDC95for ST were 0.37 and 1.02, respectively.Conclusion:This study found that the ST has an excellent test–retest reliability in patients with TKA. It is an effective and reliable tool for measuring dynamic standing balance and participant falls. As a performance-based clinical test, the ST is easy to score, can be applied in a short time as part of the routine medical examination. Therefore, inclusion of ST into a more comprehensive battery of performance-based measures of standing balance and lower limb motor control function in subjects with TKA should be considered.References:[1]Si, H. B., Zeng, Y., Zhong, J., et al. (2017). The effect of primary total knee arthroplasty on the incidence of falls and balance-related functions in patients with osteoarthritis. Scientific reports, 7(1), 1-9.[2]Moutzouri, M., Gleeson, N., Billis, E., et al. (2017). The effect of total knee arthroplasty on patients’ balance and incidence of falls: a systematic review. Knee Surgery, Sports Traumatology, Arthroscopy, 25(11), 3439-3451.[3]Hill, K. D., Bernhardt, J., McGann, A. M., et al. (1996). A new test of dynamic standing balance for stroke patients: reliability, validity and comparison with healthy elderly. Physiotherapy Canada, 48(4), 257-262.Disclosure of Interests:None declared


Sign in / Sign up

Export Citation Format

Share Document