Two-Phase Stacked Microchannel Heat Sinks for Microelectronics Cooling

2005 ◽  
Vol 2 (2) ◽  
pp. 122-131
Author(s):  
Pradeep Hegde ◽  
K.N. Seetharamu ◽  
P.A. Aswatha Narayana ◽  
Zulkifly Abdullah

Stacked microchannel heat sinks with two-phase flow have been analyzed using the Finite Element Method (FEM). The present method is a simple and practical approach for analyzing the thermal performance of single or multi layered microchannel heat sinks with either single or two-phase flow. A unique 10 noded finite element is used for the channel discretization. Two-phase thermal resistance, pressure drop and pumping power of single, double and triple stack microchannel heat sinks are determined at different base heat fluxes ranging from 150 W/cm2 to 300 W/cm2. The temperature distribution along the length of the microchannel is also plotted. It is found that stacked microchannel heat sinks with two-phase flow are thermally more efficient than two-phase single layer microchannel heat sinks, both in terms of thermal resistance and pumping power requirements. It is observed that the thermal resistance of a double stack microchannel heat sink with two-phase flow is about 40% less than that for a single stack heat sink. A triple stack heat sink yields a further 20% reduction in the thermal resistance and at the same time operates with about 30% less pumping power compared to a single stack heat sink. The effect of channel aspect ratio on the thermal resistance and pressure drop of stacked microchannel heat sinks with two-phase flow are also studied.

Author(s):  
Weilin Qu ◽  
Seok-Mann Yoon ◽  
Issam Mudawar

Knowledge of flow pattern and flow pattern transitions is essential to the development of reliable predictive tools for pressure drop and heat transfer in two-phase micro-channel heat sinks. In the present study, experiments were conducted with adiabatic nitrogen-water two-phase flow in a rectangular micro-channel having a 0.406 × 2.032 mm cross-section. Superficial velocities of nitrogen and water ranged from 0.08 to 81.92 m/s and 0.04 to 10.24 m/s, respectively. Flow patterns were first identified using high-speed video imaging, and still photos were then taken for representative patterns. Results reveal that the dominant flow patterns are slug and annular, with bubbly flow occurring only occasionally; stratified and churn flow were never observed. A flow pattern map was constructed and compared with previous maps and predictions of flow pattern transition models. Annual flow is identified as the dominant flow pattern for conditions relevant to two-phase micro-channel heat sinks, and forms the basis for development of a theoretical model for both pressure drop and heat transfer in micro-channels. Features unique to two-phase micro-channel flow, such as laminar liquid and gas flows, smooth liquid-gas interface, and strong entrainment and deposition effects are incorporated into the model. The model shows good agreement with experimental data for water-cooled heat sinks.


2004 ◽  
Vol 126 (3) ◽  
pp. 288-300 ◽  
Author(s):  
Weilin Qu ◽  
Seok-Mann Yoon ◽  
Issam Mudawar

Knowledge of flow pattern and flow pattern transitions is essential to the development of reliable predictive tools for pressure drop and heat transfer in two-phase micro-channel heat sinks. In the present study, experiments were conducted with adiabatic nitrogen-water two-phase flow in a rectangular micro-channel having a 0.406×2.032mm2 cross-section. Superficial velocities of nitrogen and water ranged from 0.08 to 81.92 m/s and 0.04 to 10.24 m/s, respectively. Flow patterns were first identified using high-speed video imaging, and still photos were then taken for representative patterns. Results reveal the dominant flow patterns are slug and annular, with bubbly flow occurring only occasionally; stratified and churn flow were never observed. A flow pattern map was constructed and compared with previous maps and predictions of flow pattern transition models. Features unique to two-phase micro-channel flow were identified and employed to validate key assumptions of an annular flow boiling model that was previously developed to predict pressure drop and heat transfer in two-phase micro-channel heat sinks. This earlier model was modified based on new findings from the adiabatic two-phase flow study. The modified model shows good agreement with experimental data for water-cooled heat sinks.


CFD Letters ◽  
2021 ◽  
Vol 13 (12) ◽  
pp. 100-112
Author(s):  
Shugata Ahmed ◽  
Erwin Sulaeman ◽  
Ahmad Faris Ismail ◽  
Muhammad Hasibul Hasan ◽  
Zahir Hanouf

In recent years, researchers are investigating several potential applications of two-phase flow in micro-gap heat sinks; electronic cooling is one of them. Further, internal micro-fins are used to enhance the heat transfer rate. However, the pressure drop penalty due to small gap height and fin surfaces is a major concern. Hence, minimization of thermal resistance and pressure drop is required. In this paper, effects of operating conditions, e.g., wall heat flux, pumping power, and inlet void fraction, on total thermal resistance and pressure drop in a micro-gap heat sink with internal micro-fins of rectangular and triangular profiles have been investigated by numerical analysis for the R-134a coolant. Furthermore, optimization of these parameters has been carried out by response surface methodology. Simulation results show that rectangular micro-fins show superior performance compared to triangular fins in reducing thermal resistance. Finally, for an optimum condition (7.1202×10-5 W pumping power, 1.2×107 Wm-2 heat flux, and 0.03 inlet void fraction), thermal resistance and pressure drop are reduced by 56.3% and 87.2%, respectively.


Entropy ◽  
2018 ◽  
Vol 21 (1) ◽  
pp. 16 ◽  
Author(s):  
Daxiang Deng ◽  
Guang Pi ◽  
Weixun Zhang ◽  
Peng Wang ◽  
Ting Fu

This work numerically studies the thermal and hydraulic performance of double-layered microchannel heat sinks (DL-MCHS) for their application in the cooling of high heat flux microelectronic devices. The superiority of double-layered microchannel heat sinks was assessed by a comparison with a single-layered microchannel heat sink (SL-MCHS) with the same triangular microchannels. Five DL-MCHSs with different cross-sectional shapes—triangular, rectangular, trapezoidal, circular and reentrant Ω-shaped—were explored and compared. The results showed that DL-MCHS decreased wall temperatures and thermal resistance considerably, induced much more uniform wall temperature distribution, and reduced the pressure drop and pumping power in comparison with SL-MCHS. The DL-MCHS with trapezoidal microchannels performed the worst with regard to thermal resistance, pressure drop, and pumping power. The DL-MCHS with rectangular microchannels produced the best overall thermal performance and seemed to be the optimum when thermal performance was the prime concern. Nevertheless, the DL-MCHS with reentrant Ω-shaped microchannels should be selected when pumping power consumption was the most important consideration.


Sign in / Sign up

Export Citation Format

Share Document