scholarly journals Keep pushing! Limiting interruptions to CPR; bag-valve mask versus i-gel® airway ventilation

2016 ◽  
Vol 21 ◽  
pp. 21-32
Author(s):  
Craig Vincent-Lambert ◽  
Andrew Makkink ◽  
Fredrick Kloppers

Background: Recent recommendations made by ILCOR have de-emphasised the role of advanced airway management such as “endotracheal intubation” (ETI) during cardiac arrest in favour of maximising the number of chest compressions performed by rescuers. Maximising time available for compressions is achieved by minimising hands-off time (HOT). This has led to first responders and paramedics performing single rescuer CPR using a bag-valve-mask (BVM) device as opposed to the historical practice of intubating and ventilating via an endotracheal tube. Bag-valve-mask ventilations, especially during single rescuer CPR, are however associated with complications potentially resulting in increased ventilation times. More time spent on ventilations in the single rescuer scenario naturally leads to an increase in HOT and less time being available for compressions. It is postulated that the use of an appropriate supraglottic airway device (SAD) may decrease the time spent on the ventilation component of CPR and result in a decrease in HOT.Objectives: This pilot study evaluated how interruptions to chest compressions or hands-off time (HOT) are affected by the placement of an i-gel® airway vs. simple BVM ventilation during single rescuer CPR.Method: 16 participants performed two, ten-minute single rescuer CPR simulations, firstly using the BVM and later the i-gel® airway for ventilation. Data pertaining to ventilations and HOT in each scenario was statistically analysed and compared.Results: The i-gel® airway demonstrated a superior ease of ventilation compared to BVM alone and resulted in a reduction of time spent on ventilations overall. The i-gel® however took a mean of 29 s, ± 10 s, to secure which contributes considerably to HOT.Conclusion: The use of the i-gel® airway resulted in a considerable decrease in the amount of time spent on ventilations and in more compressions being performed. The overall reduction in HOT was, however, offset by the time it took to secure the device. Further investigation into the use and securing of the i-gel® airway in single rescuer CPR is recommended.

2021 ◽  
Vol 11 (1) ◽  
pp. 217
Author(s):  
Loric Stuby ◽  
Laurent Jampen ◽  
Julien Sierro ◽  
Maxime Bergeron ◽  
Erik Paus ◽  
...  

Early insertion of a supraglottic airway (SGA) device could improve chest compression fraction by allowing providers to perform continuous chest compressions or by shortening the interruptions needed to deliver ventilations. SGA devices do not require the same expertise as endotracheal intubation. This study aimed to determine whether the immediate insertion of an i-gel® while providing continuous chest compressions with asynchronous ventilations could generate higher CCFs than the standard 30:2 approach using a face-mask in a simulation of out-of-hospital cardiac arrest. A multicentre, parallel, randomised, superiority, simulation study was carried out. The primary outcome was the difference in CCF during the first two minutes of resuscitation. Overall and per-cycle CCF quality of compressions and ventilations parameters were also compared. Among thirteen teams of two participants, the early insertion of an i-gel® resulted in higher CCFs during the first two minutes (89.0% vs. 83.6%, p = 0.001). Overall and per-cycle CCF were consistently higher in the i-gel® group, even after the 30:2 alternation had been resumed. In the i-gel® group, ventilation parameters were enhanced, but compressions were significantly shallower (4.6 cm vs. 5.2 cm, p = 0.007). This latter issue must be addressed before clinical trials can be considered.


JAMA ◽  
2018 ◽  
Vol 320 (8) ◽  
pp. 779 ◽  
Author(s):  
Jonathan R. Benger ◽  
Kim Kirby ◽  
Sarah Black ◽  
Stephen J. Brett ◽  
Madeleine Clout ◽  
...  