scholarly journals Quantitative determination of ciprofibrate in tablets by derivative UV spectroscopy and RP-HPLC method

2012 ◽  
Vol 74 (2) ◽  
pp. 168
Author(s):  
PS Jain ◽  
HN Jivani ◽  
RN Khatal ◽  
SJ Surana
INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (03) ◽  
pp. 44-51
Author(s):  
B. Sabbagh ◽  
B. V. S. Lokesh ◽  
G. A. Akouwah ◽  

Two methods were developed for the determination of dapagliflozin (DAPA) in pure form and in tablets. The procedure utilized was UV-Visible Spectroscopy and RP-HPLC with PDA detector to quantify DAPA in bulk and tablets. The sensitive linear range was identified for both methods within 0.5-5.0μg/mL. The linear regression analysis was identified for both methods with correlation coefficient(r)>0.99. The LOD and LOQ values were found to be 0.05 μg/mL and 0.5 μg/mL for the method by UV-Spectroscopy. The molar absorptivity (ε) was calculated as 1.27 X 105 L.mol-1cm-1. The RP-HPLC method produced LOD and LOQ values of 1.0 ng/mL and 0.5 μg/mL. Both methods were simple, precise, reproducible to quantify the amount of unknown in bulk as well as in tablets and estimated accurately within the range of 100.0±0.5%. Statistical analysis was performed on the data obtained. There was no significant difference between the developed and reported methods with p>0.05. Both methods can be applied for routine analysis of DAPA in bulk and tablets with good accuracy and precision.


2018 ◽  
Vol 4 (5) ◽  
pp. 702-705 ◽  
Author(s):  
Sreenivasa Charan Archakam ◽  
Sridhar Chenchugari ◽  
Chandrasekhar Kothapalli Banoth

2020 ◽  
Vol 10 (1) ◽  
pp. 76-86 ◽  
Author(s):  
Santosh A. Kumbhar ◽  
Chandrakant R. Kokare ◽  
Birendra Shrivastava ◽  
Hira Choudhury

Background: It has been hypothesized that delivery of aripiprazole through nanoemulsion formulation would better deliver the drug into the central nervous system to treat major depressive conditions in psychological patients. Due course of formulation development, to determine solubility of the drug in different matrices and nanoemulsion is an important step. Materials & Methods: Therefore, a simple, rapid and selective reversed phase high performance liquid chromatographic (RP-HPLC) method was developed and validated for the determination of aripiprazole as per International Conference of Harmonization (ICH) guidelines. Satisfactory analysis method was employed for the quantitative determination of aripiprazole during pre-formulation development. Results and Discussion: The separation technique was achieved using the mobile phases of methanol-acetonitrile, 80:20 (v/v) delivered at 1.0 mL.min-1 flow rate through HIQ SIL C18 250x4.6 mm (5 μm particle size) column and detected at 218 nm wavelength. The method depicted linear calibration plots within the range of 5 to 50 µg.mL-1 with a determination coefficient (r2) of 0.9991 calculated by least square regression method. The validated method was sensitive with LOD of 10.0 ng.mL-1 and 30.0 ng.mL-1 of LOQ. The intra-day and inter-day precision values were ranged between 0.37-0.89 and 0.63-1.11 respectively, with accuracy ranging from 98.24 to 100.88 and 97.03 to 100.88, respectively. This developed and validated method was found to be sensitive for the determination of aripiprazole for the first time from various oils, surfactants, co-surfactants, and nanoemulsion formulation. Conclusion: This RP-HPLC method was successfully implemented for the quantitative determination of aripiprazole at developmental stages of nanoemulsion formulation.


2009 ◽  
Vol 63 (2) ◽  
pp. 87-93 ◽  
Author(s):  
Ivana Savic ◽  
Goran Nikolic ◽  
Vladimir Bankovic ◽  
Ivan Savic

A sensitive and selective RP-HPLC method was developed and validated for the quantitative determination of trimazolin hydrochloride in nasal drops formulations. The mobile phase composition was water-acetonitrile (50:50, v/v) and the UV detection was carried out at 270 nm. Linearity range in the concentration range of 10 to 110 ?g cm-3. The method was tested and validated for various parameters according to ICH guidelines. The detection and quantization limits were found to be 1.45 and 4.8 ?g cm-3, respectively. The results demonstrated that the procedure for estimation of trimazolin hydrochloride in nasal drops formulations was accurate, precise and reproducible.


2020 ◽  
Vol 7 (2) ◽  
pp. 106-120
Author(s):  
Benny Antony ◽  
Merina Benny ◽  
Binu T. Kuruvilla ◽  
Anu Sebastian ◽  
Anu Aravind Aravindakshan Pillai ◽  
...  

Background:: Withanolide glycosides in Ashwagandha (Withania somnifera), are important metabolites attributed with widely acclaimed therapeutic potential for which validated methods for quantitative determination are limited. Objective:: The primary objective was to develop and validate a Reversed-Phase High Performance Liquid Chromatography (RP-HPLC) method for simultaneous quantification of total withanolide glycosides (WG), withanoside IV and withaferin A present in ashwagandha extract.The study also aimed to identify various other constituents present in the extract. Materials and Methods: Aqueous methanol extract (AME) of Ashwagandha was prepared and fractionated into two viz. flavonoid rich fraction (FF) and withanolide rich fraction (WF). RP-HPLC method was developed and validated for the estimation of total WG in ashwagandha extract according to ICH guidelines. Preparative HPLC based purification of major compounds from WF fraction was carried out and constituents were identified using spectroscopic techniques. HPLC chemical profiling of WF before and after acid hydrolysis under controlled conditions was carried out to further confirm the glycosidic compounds. Results and Discussion: The RP-HPLC method gave a precise differentiation of flavonoids, withanolides and WG present in ashwagandha extract. The method demonstrated good reliability and sensitivity, and can be conveniently used for the quantification of total WG, withanoside IV and withaferin A present in ashwagandha extracts. According to this method, a purified fraction (WF) prepared from roots and leaves of Ashwagandha comprise 35% of total WG, 3.27% of withanoside IV and 2.40% of Withaferin A. The method was also applied to different products prepared from Ashwagandha with total withanolide glycosides ranged from 1.5% to 60%, and the results were found to be reproducible. Identification of the individual chemical constituents as well as the acid hydrolytic pattern of the extract further supported the reliability of the developed method for the quantitative determination of total WG. This study also reported a new withanolide glycoside named, cilistol V-6’-O-glucoside (Aswanoside) along with some other known withanolide glycosides. Conclusion:: A Reversed-Phase High Performance Liquid Chromatography (RP-HPLC) method was developed and validated for the quantitative determination of total WG, withanoside IV and withaferin A present in ashwagandha extract according to ICH guidelines. This study also reported a new withanolide glycoside named, cilistol V-6’-O-glucoside (Aswanoside) along with some other known WG.


2019 ◽  
Vol 10 (02) ◽  
Author(s):  
Veera S. Pulusu ◽  
Krishna C. Routhu ◽  
Soma SB. Chikkaswamy

2020 ◽  
Vol 10 (1) ◽  
pp. 92-96
Author(s):  
Balakrishna Tiwari ◽  
Mrunal K. Shirsat ◽  
Amol Kulkarni

Brinzolamide is inhibitor of carbonic anhydride and is highly specific and non-competitive. The aim of the present study is to develop a simple, precise, accurate, sensitive RP-HPLC method for the determination of bulk drug. The objective of the method validation is to demonstrate whether the method was suited for the intended purpose. The method was validated as per the ICH guidelines. The method was validated for linearity, precision (repeatability, intermediate precision), accuracy, specificity, robustness, ruggedness, limit of detection and limit of quantification. Cosmosil (4.6X250mm, 5 μ) column was used for separation. The selected wavelength for Brinzolamide was 254 nm. The mobile phase consists of Acetonitrile: Potassium dihydrogen phosphate buffer (40:60). Flow rate was delivered at 1.0 mL/min. Appropriate dilutions of standard stock solutions were prepared to get desired concentrations in the range of 100-500 mcg/ml. The equation od standard curve was y = 441.8x + 1132 and R2 = 0.998. The RT obtained was 6.6167 minutes. Keywords: Brinzolamide, UV spectroscopy, RP-HPLC, ICH


Sign in / Sign up

Export Citation Format

Share Document