scholarly journals Scheimpflug imaging in anterior megalophthalmos

2013 ◽  
Vol 61 (1) ◽  
pp. 32 ◽  
Author(s):  
Gabor Nemeth ◽  
Andras Berta ◽  
Ziad Hassan ◽  
Laszlo Modis
2015 ◽  
Vol 2015 ◽  
pp. 1-3
Author(s):  
Nishant Nawani ◽  
Arun K. Jain ◽  
Ramandeep Singh

Purpose. With this report we describe ultrasound biomicroscopic (UBM) findings in a patient with anterior megalophthalmos before and after undergoing phacoemulsification with posterior chamber intraocular lens implantation.Methods. Phacoemulsification was carried out for nuclear sclerosis in both eyes of a patient diagnosed with anterior megalophthalmos. The patient was subjected to detailed ophthalmic examination including ultrasound biomicroscopy and Scheimpflug imaging prior to and after surgery. Preoperative ultrasound biomicroscopy revealed a deep anterior chamber with posterior bowing of the midperipheral iris in both eyes. The ciliary processes were inserted on the posterior surface of the iris. UBM was repeated postoperatively as well.Results. Phacoemulsification and posterior chamber intraocular lens implantation (IOL) were carried out successfully in both eyes. The IOLs were well centered and captured within the anterior capsulorhexis. The anterior chambers were hyperdeep, 6.24 mm (OD) and 6.08 mm (OS), respectively. The posterior bowing of the midperipheral iris was absent, with the iris having a more flat profile.Conclusion. UBM findings in anterior megalophthalmos seemed to partially resolve after cataract surgery. The anterior chamber deepens appreciably as well.


Author(s):  
Bishr Agha ◽  
Raimund Forster ◽  
Thomas Kohnen ◽  
Ingo Schmack

Abstract Purpose To evaluate the potential impact of rebubbling on the anterior segment parameters and refractive outcomes in patients with graft detachment following uneventful DMEK for Fuchs endothelial dystrophy (FED). Methods Retrospective institutional cohort study of comparing 34 eyes of 31 patients with rebubbling for graft detachment following Descemet membrane endothelial keratoplasty (DMEK) to 33 eyes of 28 patients with uneventful DMEK. Main outcome parameters were various corneal parameters obtained by Scheimpflug imaging, refractive outcome, corrected distance visual acuity (CDVA), and endothelial cell density (ECD). Results Anterior and posterior corneal astigmatism, corneal densitometry, central corneal thickness, and anterior chamber depth and volume showed no significant differences. Preoperative distribution of astigmatism axis orientations showed a high proportion of anterior corneal with-the-rule astigmatism (71%) in eyes requiring rebubbling. Mean postoperative cylinder in the rebubbling group (1.21 ± 0.85 D) was significantly higher compared to the controls (p = 0.04), while differences in spherical equivalent (SE) were insignificant (p = 0.24). Postoperative CDVA was 0.11 ± 0.11 in the control group compared to 0.21 ± 0.17 in the rebubbling group (p = 0.03). Eyes with subsequent rebubbling demonstrated a significantly higher endothelial cell loss (56% versus 37%) (p < 0.001). Conclusion Apart from higher cylinder values, refractive outcome and corneal parameters assessed by Scheimpflug imaging were comparable in eyes with rebubbling and controls. However, a reduced visual acuity and an increased endothelial cell loss should be taken into consideration prior to rebubbling especially in eyes with circumscribed graft detachment.


Author(s):  
Bishr Agha ◽  
Nura Ahmad ◽  
Daniel G. Dawson ◽  
Thomas Kohnen ◽  
Ingo Schmack

Abstract Purpose To analyze refractive and topographic changes secondary to Descemet membrane endothelial keratoplasty (DMEK) in pseudophakic eyes with Fuchs’ endothelial dystrophy (FED). Methods Eighty-seven pseudophakic eyes of 74 patients who underwent subsequent DMEK surgery for corneal endothelial decompensation and associated visual impairment were included. Median post-operative follow-up time was 12 months (range: 3–26 months). Main outcome measures were pre- and post-operative manifest refraction, anterior and posterior corneal astigmatism, simulated keratometry (CASimK) and Q value obtained by Scheimpflug imaging. Secondary outcome measures included corrected distance visual acuity (CDVA), central corneal densitometry, central corneal thickness, corneal volume (CV), anterior chamber volume (ACV) and anterior chamber depth (ACD). Results After DMEK surgery, mean pre-operative spherical equivalent (± SD) changed from + 0.04 ± 1.73 D to + 0.37 ± 1.30 D post-operatively (p = 0.06). CDVA, proportion of emmetropic eyes, ACV and ACD increased significantly during follow-up. There was also a significant decrease in posterior corneal astigmatism, central corneal densitometry, central corneal thickness and corneal volume over time (p = 0.001). Only anterior corneal astigmatism and simulated keratometry (CASimK) remained fairly stable after DMEK. Conclusion Despite tendencies toward a hyperopic shift, changes in SE were not significant and refraction remained overall stable in pseudophakic patients undergoing DMEK for FED. Analysis of corneal parameters by Scheimpflug imaging mainly revealed changes in posterior corneal astigmatism pointing out the relevance of posterior corneal profile changes during edema resolution after DMEK.


2021 ◽  
pp. 112067212199472
Author(s):  
Luis Izquierdo ◽  
Ana M Rodríguez ◽  
Ramón A Sarquis ◽  
Diego Altamirano ◽  
Maria A Henriquez

Purpose: To evaluate and compare visual and refractive outcomes after implantation of the intracorneal continuous ring 360° arc (ICCR) versus the intracorneal ring segment 340° arc (ICRS) using femtosecond laser for central keratoconus. Setting: Research Department, Oftalmosalud, Instituto de Ojos, Lima, Peru. Methods: Randomized study that included 40 eyes of 32 patients diagnosed with central keratoconus between November 2014 and March 2015. Twenty eyes had an implantation of ICCR (MyoRing, Dioptex GmbH, Austria) through an intrastromal pocket and 20 eyes had an implantation of ICRS (Keraring, Mediphacos, Brazil) through an intrastromal tunnel. Both procedures were performed with a femtosecond laser (LDV Z6 model, Ziemer Ophthalmic Systems AG). Visual acuity (VA), refraction, and Scheimpflug imaging analysis were performed pre- and postoperatively at 1 month and 1 year. Comparisons of means were performed using the Student’s t-test. Results: At 1 year, uncorrected VA improved 0.77 LogMAR ( p < 0.001) in the ICCR group and 0.79 LogMAR ( p = 0.01) in the ICRS group; mean sphere improvement was 5.13 Diopters (D) in the ICCR group and 6.27 D in the ICRS group ( p < 0.001 both); mean Steeper Keratometry improvement was 4.24 D in the ICCR group and 5.53 D in the ICRS group ( p < 0.001 both). In the ICCR group, mean decrease in the pachymetry at the thinnest point of the cornea was 32.16 µm ( p = 0.01), and in the ICRS group, mean increase was 4.2 µm at 1 year ( p = 0.61). Conclusion: Intracorneal continuous ring 360° arc (ICCR) and intracorneal ring segment 340° (ICRS) are effective treatments for central keratoconus. No significant differences between rings were found on visual acuity, refraction, and keratometry improvement.


2019 ◽  
Vol 38 (1) ◽  
pp. 592-609
Author(s):  
V. Havran ◽  
J. Hošek ◽  
Š. Němcová ◽  
J. Čáp

2014 ◽  
Vol 53 (1) ◽  
pp. 21-27 ◽  
Author(s):  
Yusuf Koçluk ◽  
Zuleyha Yalniz-Akkaya ◽  
Ayse Burcu ◽  
Firdevs Örnek

PLoS ONE ◽  
2014 ◽  
Vol 9 (10) ◽  
pp. e108882 ◽  
Author(s):  
Lóránt Dienes ◽  
Kinga Kránitz ◽  
Éva Juhász ◽  
Andrea Gyenes ◽  
Ágnes Takács ◽  
...  

2013 ◽  
Vol 72 (2) ◽  
pp. 99-102 ◽  
Author(s):  
Renato Ambrósio Jr ◽  
Isaac Ramos ◽  
Allan Luz ◽  
Fernando Correa Faria ◽  
Andreas Steinmueller ◽  
...  

Eye ◽  
2019 ◽  
Vol 33 (5) ◽  
pp. 826-832 ◽  
Author(s):  
Devesh Kumawat ◽  
Tanveer Alam ◽  
Pranita Sahay ◽  
Rohan Chawla

Sign in / Sign up

Export Citation Format

Share Document