scholarly journals The effect of two cross-linking agents on dentin bond strength of resin-modified glass ionomer

2017 ◽  
Vol 11 (04) ◽  
pp. 486-490
Author(s):  
Fereshteh Shafiei ◽  
Maryam Firouzmandi ◽  
Moona Zamanpour

ABSTRACT Objectives: The hybrid layer at the interface of resin-modified glass ionomer cements and dentin is prone to degradation by endogenous matrix metalloproteinases. We aimed to investigate the effect of two types of collagen crosslinkers, carbodiimide and proanthocyanidin (PA), on immediate and medium-term bond strength of a resin-modified glass ionomer to dentin. Materials and Methods: Seventy-two molars were flattened on the occlusal surface to expose dentin. The specimens were divided into control, 1-ethyl-3-(3-dimethylaminopropy) carbodiimide hydrochloride (EDC), and PA groups (n = 24). In the EDC and PA groups, carbodiimide and PA solutions were applied for 1 min, respectively. Resin-modified glass ionomer was bonded. Half of the specimens in each group were tested for shear bond strength after 24 h and the other half were tested after 6 months. Statistical Analysis: Data were analyzed with SPSS version 16 (SPSS Inc, Chicago, IL, USA), using two-way ANOVA, and subgroup analysis was performed using one-way ANOVA, Tukey's test, and t-test. Results: Two-way ANOVA showed that treatment and time affected the bond strength. Carbodiimide and PA did not affect the immediate bond strength (P = 0.51). After 6 months, the bond strength of the EDC group was significantly lower than that of the control and PA groups. Bond strength of the control and PA groups increased after 6 months (P ≤ 0.002). Conclusion: PA did not interfere with maturation of RMGIC unlike carbodiimide. Therefore, it can be suggested as an matrix metalloproteinase inhibitor before bonding of resin-modified glass ionomer to dentin.

2011 ◽  
Vol 05 (02) ◽  
pp. 150-156 ◽  
Author(s):  
Farid S El-Askary ◽  
Mohammed S Nassif

ABSTRACTObjectives: The purpose of this study was to evaluate the effect of the pre-conditioning step using different dentin conditioners on the shear bond strength (SBS) of the nano-filled resin-modified glass ionomer (RMGI) to dentin. Methods: Twenty-four human molars were used in this study. Subsequent to teeth sectioning in the mesio-distal direction and creation of the smear layer, the teeth were divided into six groups with and without the pre-conditioning step. Dentin surfaces were restored with RMGI cylinders and the specimens were stored in distilled water at 37ºC for 24 hours. SBS test were performed using a Universal Testing Machine at a crosshead speed of 0.5 mm/minute. Statistical analysis was performed using One-Way ANOVA followed by Duncan’s Multiple Range Test. RMGI/dentin interface was evaluated using SEM operated at 12 Kv at 2000X magnification. Results: 35% phosphoric acid and EDTA yielded significantly higher SBS (12.0±1.8 and 11.9±4.4 MPa, respectively), compared to all tested groups. In addition, 25% polyacrylic acid (8.6±3.1 MPa) reported significantly higher SBS than the nano-filled RMGI when applied according to manufacturer instructions (5.5±2.2 MPa). When nano-filled RMGI was applied without its nano-primer, or directly over 25% polyacrylic acid conditioned dentin exhibited 100% pre-test failure, and their SBS were expressed as 0.0±0.0 MPa. SEM revealed that the nano-primer was unable to decalcify and hybridize the dentin surface. Conclusions: Based on the results of the current study, the pre-conditioning step effectively improves the SBS of nano-filled RMGI to dentin. The self-adhesiveness of nano-filled RMGI was not proved in this study. (Eur J Dent 2011;5:150-156)


2020 ◽  
Vol 8 (02) ◽  
pp. 49-54
Author(s):  
Salil Mehra ◽  
Ashu K. Gupta ◽  
Bhanu Pratap Singh ◽  
Mandeep Kaur ◽  
Ashwath Kumar

Abstract Introduction The aim of the current study was to evaluate shear bond strength of resin composite bonded to Theracal LC, Biodentine, and resin-modified glass ionomer cement (RMGIC) using universal adhesive and mode of fracture. Materials and Methods A total of 50 caries-free maxillary and mandibular molars extracted were taken; occlusal cavities were prepared, mounted in acrylic blocks, and divided into five groups based on the liner used. Group 1: Biodentine liner placed into the cavity and bonding agent and resin composite applied after 12 minutes. Group 2: Biodentine liner placed into the cavity and bonding agent and resin composite applied after 14 days. Group 3: RMGIC liner placed into the cavity and bonding agent and resin composite applied immediately. Group 4: RMGIC liner placed into the cavity and bonding agent and resin composite applied after 7 days. Group 5: Theracal LC liner placed into the cavity and bonding agent and resin composite applied immediately. Each sample was bonded to resin composite using universal adhesive. Shear bond strength analysis was performed at a cross-head speed of 0.1 mm/min. Statistical Analysis  Statistical analysis was performed with one-way analysis of variance and posthoc Bonferroni test using SPSS version 22.0. Results and Conclusion Biodentine liner when bonded immediately to resin composite showed minimum shear bond strength. RMGIC when bonded to resin composite after 7 days showed maximum shear bond strength. Mode of fracture was predominantly cohesive in groups having Biodentine and Theracal LC as liner.


2012 ◽  
Vol 17 (6) ◽  
pp. 154-159 ◽  
Author(s):  
Marcel M. Farret ◽  
Eduardo Martinelli de Lima ◽  
Eduardo Gonçalves Mota ◽  
Hugo Mitsuo S. Oshima ◽  
Gabriela Maguilnik ◽  
...  

OBJECTIVE: To evaluate the mechanical properties of three glass ionomers cements (GICs) used for band cementation in Orthodontics. METHODS: Two conventional glass ionomers (Ketac Cem Easy mix/3M-ESPE and Meron/Voco) and one resin modified glass ionomer (Multi-cure Glass ionomer/3M-Unitek) were selected. For the compressive strength and diametral tensile strength tests, 12 specimens were made of each material. For the microhardness test 15 specimens were made of each material and for the shear bond strength tests 45 bovine permanent incisors were used mounted in a self-cure acrylic resin. Then, band segments with a welded bracket were cemented on the buccal surface of the crowns. For the mechanical tests of compressive and diametral tensile strength and shear bond strength a universal testing machine was used with a crosshead speed of 1,0 mm/min and for the Vickers microhardness analysis tests a Microdurometer was used with 200 g of load during 15 seconds. The results were submitted to statistical analysis through ANOVA complemented by Tukey's test at a significance level of 5%. RESULTS: The results shown that the Multi-Cure Glass Ionomer presented higher diametral tensile strength (p < 0.01) and compressive strength greater than conventional GICs (p = 0.08). Moreover, Ketac Cem showed significant less microhardness (p < 0.01). CONCLUSION: The resin-modified glass ionomer cement showed high mechanical properties, compared to the conventional glass ionomer cements, which had few differences between them.


10.2341/05-13 ◽  
2006 ◽  
Vol 31 (2) ◽  
pp. 212-218 ◽  
Author(s):  
A. E. Souza-Gabriel ◽  
F. L. B. Amaral ◽  
J. D. Pécora ◽  
R. G. Palma-Dibb ◽  
S. A. M. Corona

Clinical Relevance Er:YAG laser adversely affected the adhesion of resin-modified glass ionomer cements to tooth structure and cannot be considered an alternative technique to the conventional turbine handpiece.


2013 ◽  
Vol 38 (2) ◽  
pp. 186-196 ◽  
Author(s):  
Camila Sabatini ◽  
Manthan Patel ◽  
Eric D'Silva

SUMMARY Objective To evaluate the shear bond strength (SBS) of three self-adhesive resin cements and a resin-modified glass ionomer cement (RMGIC) to different prosthodontic substrates. Materials and Methods The substrates base metal, noble metal, zirconia, ceramic, and resin composite were used for bonding with different cements (n=12). Specimens were placed in a bonding jig, which was filled with one of four cements (RelyX Unicem, Multilink Automix, Maxcem Elite, and FujiCEM Automix). Both light-polymerizing (LP) and self-polymerizing (SP) setting reactions were tested. Shear bond strength was measured at 15 minutes and 24 hours in a testing device at a test speed of 1 mm/min and expressed in MPa. A Student t-test and a one-way analysis of variance (ANOVA) were used to evaluate differences between setting reactions, between testing times, and among cements irrespective of other factors. Generalized linear regression model and Tukey tests were used for multifactorial analysis. Results Significantly higher mean SBS were demonstrated for LP mode relative to SP mode (p&lt;0.001) and for 24 hours relative to 15 minutes (p&lt;0.001). Multifactorial analysis revealed that all factors (cement, substrate, and setting reaction) and all their interactions had a significant effect on the bond strength (p&lt;0.001). Resin showed significantly higher SBS than other substrates when bonded to RelyX Unicem and Multilink Automix in LP mode (p&lt;0.05). Overall, FujiCEM demonstrated significantly lower SBS than the three self-adhesive resin cements (p&lt;0.05). Conclusions Overall, higher bond strengths were demonstrated for LP relative to SP mode, 24 hours relative to 15 minutes and self-adhesive resin cements compared to the RMGICs. Bond strengths also varied depending on the substrate, indicating that selection of luting cement should be partially dictated by the substrate and the setting reaction.


2018 ◽  
Vol 29 (2) ◽  
pp. 128-132 ◽  
Author(s):  
Gabriela Cristina Santin ◽  
Alexandra Mussolino de Queiroz ◽  
Regina Guenka Palma-Dibb ◽  
Harley Francisco de Oliveira ◽  
Paulo Nelson Filho ◽  
...  

Abstract Patients undergoing radiotherapy treatment present more susceptibility to dental caries and the use of an orthodontic device increases this risk factor due to biofilm accumulation around the brackets. The objective of this study was to evaluate the shear bond strength to irradiated permanent teeth of orthodontic brackets bonded with conventional glass ionomer cement and resin-modified glass ionomer cement due to the fluoride release capacity of these materials. Ninety prepared human premolars were divided into 6 groups (n=15), according to the bonding material and use or not of radiation: CR: Transbond XT composite resin; RMGIC: Fuji Ortho LC conventional glass ionomer cement; GIC: Ketac Cem Easymix resin-modified glass ionomer cement. The groups were irradiated (I) or non-irradiated (NI) prior to bracket bonding. The specimens were subjected to a fractioned radiation dose of 2 Gy over 5 consecutive days for 6 weeks. After the radiotherapy, the brackets were bonded on the specimens with Transbond XT, Fuji Ortho LC and Ketac Cem Easymix. After 24 h, the specimens were subjected to shear bond strength test. The image of enamel surface (classified by Adhesive Remnant Index - ARI) was also evaluated and its frequency was checked among groups/subgroups. The shear bond strength variable was evaluated with ANOVA and Tukey’s post-hoc test. GIC group showed the lowest adhesion values among the groups (p<0.05). There was no statistically significant difference among non-irradiated and irradiated groups (p>0.05). As for the ARI, the CR-I group showed the highest material retention on enamel surface among the irradiated groups. RMGIC group showed the highest values for shear bond strength and presented ARI acceptable for clinical practices.


2006 ◽  
Vol 129 (2) ◽  
pp. 273-276 ◽  
Author(s):  
Vittorio Cacciafesta ◽  
Maria Francesca Sfondrini ◽  
Paola Stifanelli ◽  
Andrea Scribante ◽  
Catherine Klersy

Sign in / Sign up

Export Citation Format

Share Document