scholarly journals Usefulness of Pulsed Arterial Spin Labeling Magnetic Resonance Imaging in New.onset Seizure Patients and Its Comparison with Dynamic Susceptibility Contrast Magnetic Resonance Imaging

2017 ◽  
Vol 08 (04) ◽  
pp. 569-574 ◽  
Author(s):  
Varun Bansal ◽  
Suresh Kumar ◽  
Sudhir Sharma ◽  
Sanjiv Sharma ◽  
R. G. Sood

ABSTRACT Introduction: Dynamic susceptibility contrast (DSC) perfusion and pulsed arterial spin labeling (PASL) imaging are newer advanced magnetic resonance sequences which are capable of detecting vascular changes in patients with new-onset seizure disorder even when no significant abnormalities are visualized on conventional sequences. The purpose of our study is to establish utility of arterial spin labeling (ASL) in new-onset seizure patients and compare ASL with DSC perfusion sequence. Materials and Methods: Twenty-six patients coming to emergency department with new-onset seizure disorder were evaluated using DSC and ASL sequence. Perfusion asymmetry was assessed using region of interests taken at places where signal asymmetry was maximal. Results: PASL sequence showed focal vascular changes in form of hyperperfusion in four patients, hypoperfusion in nine patients, and normal perfusion in 13 patients. Altered perfusion whether hypo/hyperperfusion was detected in five out of 16 patients even when conventional sequences were normal. There was strong positive linear correlation between ASL and DSC with P = 0.001. Conclusion: Noninvasive PASL is capable of detecting vascular changes induced by seizure and is comparable to DSC sequence. Thus, it is recommended when there is a need for repeated evaluations; in follow-up/therapy response assessment and when contrast administration is contraindicated.

2016 ◽  
Vol 37 (3) ◽  
pp. 1108-1119 ◽  
Author(s):  
Enedino Hernández-Torres ◽  
Nora Kassner ◽  
Nils Daniel Forkert ◽  
Luxi Wei ◽  
Vanessa Wiggermann ◽  
...  

Measurements of cerebral perfusion using dynamic susceptibility contrast magnetic resonance imaging rely on the assumption of isotropic vascular architecture. However, a considerable fraction of vessels runs in parallel with white matter tracts. Here, we investigate the effects of tissue orientation on dynamic susceptibility contrast magnetic resonance imaging. Tissue orientation was measured using diffusion tensor imaging and dynamic susceptibility contrast was performed with gradient echo planar imaging. Perfusion parameters and the raw dynamic susceptibility contrast signals were correlated with tissue orientation. Additionally, numerical simulations were performed for a range of vascular volumes of both the isotropic vascular bed and anisotropic vessel components, as well as for a range of contrast agent concentrations. The effect of the contrast agent was much larger in white matter tissue perpendicular to the main magnetic field compared to white matter parallel to the main magnetic field. In addition, cerebral blood flow and cerebral blood volume were affected in the same way with angle-dependent variations of up to 130%. Mean transit time and time to maximum of the residual curve exhibited weak orientation dependency of 10%. Numerical simulations agreed with the measured data, showing that one-third of the white matter vascular volume is comprised of vessels running in parallel with the fibre tracts.


Sign in / Sign up