A rapid high-performance liquid chromatography method for the simultaneous estimation of water-soluble vitamin in ten wild edible plants consumed by the tribal people of North-eastern Region in India

2018 ◽  
Vol 14 (55) ◽  
pp. 72 ◽  
Author(s):  
Tapan Seal ◽  
Kausik Chaudhuri ◽  
Basundhara Pillai
INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (01) ◽  
pp. 35-40
Author(s):  
A. S. Bagde ◽  
V. V. Khanvilkar ◽  

The present work describes a validated reverse phase high performance liquid chromatography (RPHPLC) method for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate in pharmaceutical dosage from. The drugs were resolved using Hemochrom Intsil C18-5U column (250×4.6) mm in isocratic mode with mobile phase methanol: water (0.08% diethylamine, 0.02% of glacial acetic acid and pH 4.4 adjusted with orthophosphoric acid) in the ratio of 70:30 V/V at a flow rate of 1.0 mL/min. Retention time of dextromethorphan hydrobromide and quinidine sulphate were 4.9±0.2 and 3.6±0.2, respectively, at 292nm. The above mentioned method was validated as per International Conference on Harmonization (ICH) guidelines. Linear responses were obtained in concentration ranges of 5-35 μg/mL for dextromethorphan hydrobromide and 4-16 μg/mL for quinidine sulphate, with correlation coefficient (r2) of 0.999 for both the drugs. A simple, selective, accurate, precise, robust and reliable RP-HPLC method thus developed and validated for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate.


2020 ◽  
Vol 10 (4) ◽  
pp. 79-86
Author(s):  
Awdhut Pimpale ◽  
Rajendra Kakde

A Simple, precise, and accurate stability-indicating reversed-phase high-performance liquid chromatography method has been established for the simultaneous estimation of rosuvastatin calcium and fenofibrate in combined bulk and tablet formulation. The chromatographic separation was performed on reverse phase Princeton (C18) (250 mm x 4.6 mm, 5µ) column with mobile phase as a mixture of water (pH adjusted to 3.0 with orthophosphoric acid) and acetonitrile in the ratio (40:60) v/v at the flow rate 1.0 ml/min. Detection was carried out at wavelength 240 nm. The retention time under the optimized condition of Rosuvastatin calcium and Fenofibrate was found to be 2.485 & 3.905 minutes respectively. The calibration curve was linear in the range of 6-16 µg/ml and 87-232 µg/ml for rosuvastatin calcium and fenofibrate with a correlation coefficient of 0.9999 and 0.9994 respectively. Relative standard deviation values for all key parameters were less than 2.0%. The percentage recovery was found to be 99.66-100.37% and 99.13-100.44% for rosuvastatin calcium and fenofibrate respectively. The developed reversed-phase high-performance liquid chromatography method was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical, and could be used for regular quality control of rosuvastatin calcium and fenofibrate in bulk and tablet formulations.  Keywords: Rosuvastatin calcium, Fenofibrate, RP-HPLC, Method validation, ICH guidelines.


Author(s):  
BISWA RANJAN PATRA ◽  
MOHAN S ◽  
NAGARAJ GOWDA

Objective: The objective of this research work is to develop a simple, rapid, cost-effective, accurate, precise, and robust stability-indicating reversephase ultra-high performance liquid chromatography method for the quantitative estimation of telmisartan (TEL) and amlodipine (AMD) in combined tablet dosage form. Methods: The method uses Poroshell 120EC-C18 column (4.6 mm × 50 mm, 2.7 μm) with an optimized mobile phase containing acetonitrile:50 mM ammonium acetate buffer in the ratio (45:55 v/v), pH adjusted to 4.5 with acetic acid. The flow rate was 0.5 ml/min, column temperature at 25°C and detection was monitored by a PDA detector at a wavelength of 245 nm. International Conference on Harmonization (ICH) recommended stress degradation studies were performed on TEL, AMD standard drugs, and tablet formulations; further stressed samples were analyzed by the proposed method. Results: Major degradation of TEL and AMD was observed under acidic, alkali, hydrolytic and oxidation conditions. The described method was validated as per the ICH guideline and validation parameters such as system suitability, linearity, accuracy, precision, specificity, and robustness results were within acceptable limits. Conclusion: The method was found to be suitable and accurate for quantitative estimation and stability study of title drugs in pharmaceutical preparations.


Author(s):  
Sufiyan Ahmad ◽  
Mohammed Rageeb Mohammed Usman

  Objective: A simple rapid, accurate, precise, and reproducible validated reversed-phase high performance liquid chromatography method was developed for the determination of emtricitabine (EMB) and tenofovir (TEN) in bulk and tablet dosage forms.Methods: The quantification was carried out using symmetry Premsil C18 (250 mm×4.6 mm, 5 μm) Younglin (S.K.) gradient way using mobile phase comprising of methanol:water (70:30 v/v) pH 3 and a detection wavelength of 273 nm, and injection volume of 20 μL, with a flow rate of 1 ml/minutes.Results: In the developed method, the retention time of EMB and TEN were found to be 3.1667 minutes and 7.5000 minutes. The developed method was validated according to the International Conference on Harmonization (ICH) guidelines.Conclusion: The linearity, precision, range, robustness was within the limits as specified by the ICH guidelines. Hence, the method was found to be simple, accurate, precise, economic, and reproducible. Hence, it is worthwhile that the proposed methods can be successfully utilized for the routine quality control analysis EMB and TEN in bulk drug as well as in formulations.


Author(s):  
RASHMI PATIL ◽  
UTTARA JAISWAR ◽  
VANDANA JAIN

Objective: The study aims to develop and validate a novel reverse-phase high-performance liquid chromatographic method for simultaneous estimation of andrographolide and aloe-emodin in herbal formulation and validate as per the International Conference on Harmonization (ICH) guidelines. Methods: The analysis was carried on a Shimadzu LC Prominence-i 2030 model with the Lab Solution software. The column used for separation was Prontosil C18 (250×4.6 mm, 5 μ), with a mobile phase consisting of acetonitrile and 0.05% orthophosphoric acid (45:55), at a flow rate of 1 ml/min, column temperature was maintained at 28°C and effluents were monitored at 225 nm. The injection volume was 10 μl. Results: The retention time of andrographolide and aloe-emodin was found to be 4.57±0.2 min and 12.29±0.2 min, respectively. The markers were resolved using linear responses that were obtained in concentration ranges of 0.5–60 μg/ml with correlation coefficient (r2) of 0.9992 and 0.999 for andrographolide and aloe-emodin, respectively. The precision results were found to be satisfactory, which indicates that the method is precise. The recovery values lie in the range of 98–120% indicating the accuracy of the method. Conclusion: A novel, simple, accurate, precise, and robust reverse-phase high-performance liquid chromatography method was developed for the simultaneous estimation of andrographolide and aloe-emodin. The developed method can be used for analysis of the formulations containing these phytoconstituents.


Sign in / Sign up

Export Citation Format

Share Document