scholarly journals A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method

2014 ◽  
pp. 75
Author(s):  
Asma Rahman ◽  
Sarowar Jahan Sarowar ◽  
Jahirul Islam Jahirul ◽  
Rehana Begum Rehana ◽  
Ruhul Kayesh Kayesh
Author(s):  
Sayyed Nazifa Sabir Ali ◽  
Lajporiya Mobina ◽  
Manjra Mehfuza ◽  
Patel Seema ◽  
Aejaz Ahmed ◽  
...  

Aims: To develop and validate a new, simple, rapid, precise, and accurate An Eco-friendly RP-HPLC and UV-Method Development and Validation for an estimation of Favipiravir in Bulk and pharmaceutical dosage form followed by Forced Degradation Studies. Study Design: This was employed for UV-visible (200-400 nm and 400-800 nm respectively) and RP-HPLC method development using C 18 inertsil column and optimization of variables for Favipiravir estimation in bulk and formulations. Place and Duration of the Study: The present work was carried out at Ali-allana College of Pharmacy, Akkalkuwa between the duration of November-2020 to February-2021. Methodology: UV-Spectroscopic method was developed for the estimation of Favipiravir in the bulk and pharmaceutical dosage form. The solvent selected for the Favipiravir UV analysis was water, the solution in a range of 2-10µg/ml was scanned in the UV region from 200-400 nm and the λmax value was determined. The RP-HPLC method was developed on inertsil ODS-3V C18 150 mm x 4.6mm x 5μ column using buffer pH 3.5: acetonitrile [90:10] as mobile phase at flow rate 1.0 ml/min and PDA detection at 358 nm. Results: The maximum absorbance was observed at 358 nm. The wavelength 358 nm was selected for further analysis of Favipiravir. The calibration curve was determined using drug concentrations ranging from 2-10 µg/ml. The % recovery for accuracy was 100.50-100.76%. The method was to be precise with a % RSD value 0.51-1.37 and 0.77-1.78 for intraday and Interday respectively. The limit of detection (LOD) and limit of quantification (LOQ) was found to be 0.0723 &0.219 µg/ml respectively by UV method. The RP-HPLC method was shown to be linear in the 50-250 μg/ml concentration range. The limit of detection (LOD) and limit of quantification (LOQ) was found to be 2.186 & 6.626 μg/ml respectively. The method was to be precise with a % RSD value 0.25-1.53 and 0.86-1.68 for intraday and inter-day respectively. Conclusion: Here we conclude that the developed UV and RP-HPLC methods are precise, accurate, sensitive, and reproducible for the quantitative estimation of Favipiravir bulk and its formulation. The developed method can be used by the pharmaceutical industries for the routine analysis of Favipiravir, in particular by UV and RP-HPLC. The main features of the proposed method are economic and eco-friendly with less retention time around 5.0 min.


Author(s):  
MANORANJANI M

Objective: The present paper describes a simple, accurate, and precise reversed-phase high-performance liquid chromatography (HPLC) method for rapid and simultaneous quantification of netupitant (NTP) and palonosetron (PLS) in bulk and pharmaceutical dosage form. Methods: The chromatographic separation was achieved on Luna C18 (250 mm × 4.6 mm, 5 μ). Mobile phase contained a mixture of 0.1% orthophosphoric acid and acetonitrile in the ratio of 60:40 v/v, flow rate 1.0 ml/min, and ultraviolet detection at 222 nm. Results: The proposed method shows a good linearity in the concentration range of 60–900 μg/ml for NTP and 0.1–1.5 μg/ml for PLS under optimized conditions. All the precision and recovery results are in between 98 and 102%. In the entire robustness conditions, percentage of relative standard deviation is <2.0%. Degradation has minimum effect in stress condition and solutions are stable up to 24 h. This method is validated different parameters such as precision, linearity, accuracy, limit of detection, limit of quantification, ruggedness, robustness, and forced degradation study were determined according to the International Conference of Harmonization (ICH) Q2B guidelines. Conclusion: All the parameters of validation were found to be within the acceptance range of ICH guidelines. Since there is no HPLC method reported in the literature for the estimation of NTP and PLS in pharmaceutical dosage forms, there is a need to develop quantitative methods under different conditions to achieve improvement in sensitivity, selectivity, etc. Hence, the author has attempted to develop a validation and forced degradation for simultaneous quantification of NTP and PLS.


Author(s):  
GOPINATH K ◽  
YANADIRAO M ◽  
PAVANI Y ◽  
SUBBA RAO M

Objective: The present paper describes a simple, accurate, and precise reversed-phase high-performance liquid chromatography (HPLC) method for rapid and simultaneous quantification of cabozantinib (CZT) and nivolumab (NVM) in bulk and pharmaceutical dosage form. Methods: The chromatographic separation was achieved on Luna C18 (150 mm×4.6 mm, 3.5 μm). Mobile phase contained a mixture of 0.1% orthophosphoric acid and acetonitrile in the ratio of 50:50 v/v, flow rate 1.0 ml/min, and ultraviolet detection at 222 nm. Results: The proposed method shows a good linearity in the concentration range of 20–300 μg/ml for CZT and 5–75 μg/ml for NVM under optimized conditions. Precision and recovery study results are in between 98 and 102%. In the entire robustness conditions, percentage relative standard deviation is <2.0%. Degradation has minimum effect in stress condition and solutions are stable up to 24 h. Conclusion: This method is validated for different parameters such as precision, linearity, accuracy, limit of detection (LOD), limit of quantification (LOQ), ruggedness, robustness, and forced degradation study were determined according to the International Conference of Harmonization (ICH) Q2B guidelines. All the parameters of validation were found to be within the acceptance range of ICH guidelines. Since there is no HPLC method reported in the literature for the estimation of CZT and NVM in pharmaceutical dosage forms, there is a need to develop quantitative methods under different conditions to achieve improvement in sensitivity, selectivity, etc. The author declares the interest to develop a validation and forced degradation for simultaneous quantification of CZT and NVM.


Author(s):  
Rakam Gopi Krishna ◽  
M. Srinivasa Murthy ◽  
V. Kavya

The objective of the study was to develop RP-HPLC method for the determination of purity of sumatriptan in bulk and pharmaceutical dosage form. The development of an analytical method for the determination of drugs by HPLC has received considerable attention in recent years because of their importance in quality control of drugs and drug products. The aim of this current study was to develop a simple, rapid, precise, accurate and sensitive HPLC method for the analysis of sumatriptan in bulk and its pharmaceutical dosage form by using solvent system of TEA : ACN : methanol in the ratio 80:10:10 and C8 ODS Inertsil (250*4.6mm, 5i.d) stationary phase. The chromatographic condition is set at flow rate of 1ml/min with PDA detector at 221 nm. As per ICH requirements validation studies are carried out by using freshly prepared solutions. The linearity was demonstrated over the concentration range of 5-150 µg / ml and value was found to be as 0.99998. The %RSD of precision was found to be 0.260. The LOD and LOQ were found to be 1.967μg/ml and 5.961μg/ml respectively. Forced degradation studies were carried out under various stress conditions to demonstrate the stability-indicating capability of the developed RP-HPLC method. The proposed method was found to be simple, precise, accurate and validated according to the International Council for Harmonisation guidelines.


Author(s):  
G.M. Kadam ◽  
A.L. Puyad ◽  
T.M. Kalyankar

A new, economical, simple, accurate, and precise RP-HPLC method was developed for simultaneous assay and content uniformity determination of Sacubitril and Valsartan in bulk and pharmaceutical dosage form. The separation of Sacubitril and Valsartan was achieved within 6 minutes on Phenomenex Luna C18 250 mm x 4.6mm and 5µm Particle Size, column using Acetonitrile: Methanol: Water (30:55:15% v/v/v) as the mobile phase. Detection was carried out at 250 nm wavelength. The retention time of Sacubitril and Valsartan was found to be 2.361 and 3.304 min, respectively. The validation of the developed method was performed in terms of specificity, accuracy, precision, linearity, the limit of detection, the limit of quantification as mentioned in International Conference on Harmonization (ICH) guidelines. The method showed adequate sensitivity concerning linearity, accuracy, and precision over the range 12-36 μg/ml and 13-39 μg/ml for Sacubitril and Valsartan, respectively. The percentage recoveries obtained for Sacubitril and Valsartan were found to be in the range of 98.00 – 102.00 %. The proposed method is suitable for use in quality-control laboratories for quantitative analysis.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (02) ◽  
pp. 31-38
Author(s):  
R. S. Ch Phani ◽  
◽  
K. R. S. Prasad ◽  
R. M Useni

A simple, precise and stability-indicating RP-HPLC method was developed for simultaneous quantification of oxycodone (OXCD) and naltrexone (NTRX) in combined dosage form. The developed method was validated with respect to precision, linearity, accuracy, robustness, ruggedness, sensitivity and solution stability. The method was developed with ammonium di hydrogen phosphate buffer (pH 5.0) and acetonitrile in a ratio of 55:45 (v/v) as mobile phase at a flow rate of 1.0 mL/minute over Intersil ODS C18 column (250 mm × 4.6 mm×5μ).The UV detection wavelength was fixed at 235 nm. The column temperature was maintained at ambient temperature. The method showed good linearity with correlation coefficient values of 0.9990 and 0.9994 for OXCD and NTRX. The percent recoveries of the two drugs found within the limits of 98.0–102.0%. The LOQ concentrations of OXCD and NTRX are 0.625 μg/ mL and 0.075 μg/mL, respectively. The LOD concentrations of OXCD and NTRX are 0.3125 μg/mL and 0.0375 μg/mL, respectively. According to ICH guidelines forced degradation study was validated.


Author(s):  
Heena Ar Shaikh ◽  
Vandana Jain

Objective: A simple, accurate, precise, robust reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the estimation of telmisartan and nebivolol hydrochloride (HCl) simultaneously in its combined dosage form.Methods: The compounds were well resolved in an isocratic method using the mobile phase composition of acetonitrile: Buffer (potassium dihydrogen orthophosphate pH adjusted 3.1 with orthophosphoric acid) in a ratio of 40:60 v/v at a flow rate of 1.2 ml/min using C18 Shim-pack (150 mm × 4.6 mm, 5 μ) column. The detection was carried out at 280 nm.Results: The retention time of telmisartan and nebivolol HCl was 4.8 min and 6.5 min, respectively. The developed method was validated by evaluating various validation parameters such as linearity, precision, accuracy, robustness, specificity, limit of detection, and limit of quantification according to the international council for harmonization guidelines. The standard calibration curve was obtained in the concentration range of 24–56 μg/ml for telmisartan and 3–7 μg/ml for nebivolol HCl. The overall average % recovery was found out to be 100.35 for telmisartan and 98.84 for nebivolol HCl.Conclusion: Statistical analysis of the data showed that the method is reproducible and selective for the estimation of telmisartan and nebivolol HCl. The proposed method could be used for analysis of telmisartan and nebivolol HCl in their dosage form.


Sign in / Sign up

Export Citation Format

Share Document