scholarly journals Live Line Measuring the Parameters of 220 kV Transmission Lines with Mutual Inductance in Hainan Power Grid

Engineering ◽  
2013 ◽  
Vol 05 (01) ◽  
pp. 146-151
Author(s):  
Zhongzhu Xu
2013 ◽  
Vol 05 (04) ◽  
pp. 1435-1439
Author(s):  
Jianjun Su ◽  
Ronghua Zhang ◽  
Demin Cui ◽  
Yongqiang Chai ◽  
Xiaobo Li ◽  
...  

Author(s):  
Nina B. Rubtsova ◽  
Sergey Yu. Perov ◽  
Olga V. Belaya ◽  
Tatiana A. Konshina

Introduction. Electromagnetic safety of power grid facilities staff requires the exclusion of electromagnetic fields (EMF) harmful effects. EMF is evaluated by 50 Hz electric and magnetic fields (EF and MF) values in the framework of working conditions special assessment, and very rarely the analysis of the electromagnetic environment (EME) is carried out in depth. The aim of the study - EME hygienic assessment of power grid EHV facilities personnel workplace with adequate 50 Hz EF and MF levels evaluation as well as the analysis of EF and MF in the frequency range from 5 Hz to 500 Hz amplitude-frequency characteristics. Materials and methods. 50 Hz EF and MF values assessment was carried out on open switchgears (S) of substations and within sanitary breaks of 500 and 750 kV overhead power transmission lines (OTL). Measurements along to OTL trasses was performed using matrix-based method. Measurements and analysis of EF and MF values in 5-500 Hz frequency range amplitude-frequency characteristics were performed in the territory of 500 and 750 kV S. Results. Power frequency 50 Hz measurements results at 500 and 750 kV S ground-level personnel workplaces showed the presence of an excess of permissible limit values by EF intensity and the absence of an excess by MF. The measured EF values within 500 and 750 kV OTL sanitary gaps require limiting the working time of linemen due to the excess of the hygienic norms for full work shift, while the MP levels were almost completely within the standard values for persons not occupationally connected with electrical installations maintenance. MF and EE frequency range from 50 Hz to 500 Hz spectral characteristics analysis showed that 3rd harmonic percentage does not exceed 2.5% for EF and 6% for MF of the main level, the level of the 5th harmonic does not exceed 1% for EF and 3.5% for MF, the level of the 7th harmonic does not exceed 0.2% for EF and 0.8% for MF. These data show despite its low levels the contribution of MF different harmonics in a possible adverse impact on humane than EF corresponding harmonics. Conclusions. There was the confirmation of the previously justified use of the "matrix" scheme for of EF and MF values measurement along OTL routes. The relevance of to EF and MF all frequency components expos ure assessing possible health risk in extremely high voltage S territories and under OTL, based on international recommendations due to the lack of sanitary regulations in the Russian Federation for >50 Hz-30 kHz EF and MF, is shown.


1999 ◽  
Vol 22 (2) ◽  
pp. 111-119
Author(s):  
P. T. Trakadas ◽  
C. N. Capsalis

There are several cases at which, in order to evaluate the crosstalk effect among transmission lines carrying useful signals, there is a need for probabilistic approach. This paper considers the problem of crosstalk estimation between transmission lines consisting of three conductors in a homogeneous surrounding medium, where the distance between the conductors is a random variable described by uniform distribution. The transmission lines are considered as electrically short. A closed-form equation is developed for the statistical distribution of the per-unit-length mutual inductance(lm)and an analytical one is described for the evaluation of the per-unit-length capacitance(cm). Theoretical results are compared with simulated ones for validation purposes.


Sign in / Sign up

Export Citation Format

Share Document