Intravascular ultrasound in percutaneous coronary intervention for in-stent chronic total occlusion: guidance for long-term success

2020 ◽  
Vol 16 (6) ◽  
pp. e445-e447
Author(s):  
Jose Maria de la Torre Hernandez
2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
K Tanaka ◽  
A Okamura ◽  
M Iwakura ◽  
H Nagai ◽  
A Sumiyoshi ◽  
...  

Abstract Background The strategy of intravascular ultrasound (IVUS)-guided wiring for CTO PCI, that is, leading the second guidewire into the true lumen under observing by IVUS from subintimal space, is the last resort. We developed the angiography-based 3D wiring method. During establishment of the angiography-based 3D wiring method, we deduced that observation of the guidewire tip as well as the shaft named “The tip detection method” simplifies and facilitates 3D wiring under IVUS-guided wiring. Therefore, we produced New CTO IVUS which is the upgraded version of Navifocus WR IVUS by adding the pull-back transducer system. This pull-back system enables us to detect the tip as well as the shaft of the second guidewire in real time (tip detection method), which facilitates the 3D wiring technique under IVUS-guided wiring. Objective We evaluated the efficacy of the tip detection method during 3D wiring for CTO PCI with New CTO IVUS. Method We created a target pinpoint penetration model and performed the procedures using an experimental heartbeat model. The target (a tube with a lumen 0.6 mm in diameter) was placed in the distal part of a CTO 20 mm in length made of 2.5% agar. After the second guidewire (Conquest-12g) was advanced into the CTO lesion to within 5mm of the target using the angiography-based wiring, IVUS-guided wiring was performed by using Navifocus WR or New CTO IVUS each five times. Result The frequency of the puncture time was reduced using the new CTO IVUS compared to the Navifocus WR (1.7±0.8 vs. 28.8±23.2, p=0.17). The procedure time was significantly shorter using the new CTO IVUS compared to the Navifocus WR (103±61 vs. 459±373 seconds, p=0.04). Conclusion The tip detection method during 3D wiring with the new short tip IVUS with the pull-back system enables us to easily perform 3D wiring and will change the CTO PCI strategy.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
H Tanaka ◽  
T Tada ◽  
Y Fuku ◽  
T Goto ◽  
K Kadota

Abstract Background Successful recanalisation of percutaneous coronary intervention for chronic total occlusion lesions has been associated with improved survival. Purpose This study aimed to assess the impact of successful percutaneous coronary intervention for chronic total occlusion lesions on the long-term outcome of patients with impaired and preserved left ventricular ejection fraction (LVEF). Methods The study sample consisted of 842 consecutive patients (928 chronic total occlusion lesions) undergoing percutaneous coronary intervention at our institution between October 2005 and December 2009. We divided them into 3 groups by the degree of LVEF: less than 40% (severely reduced LVEF, n=140), 40% to 59% (moderately reduced LVEF, n=470), and 60% and above (normal LVEF, n=232). We evaluated mortality during the 10-year follow-up period the basis of procedural success and failure. Results The overall procedural success rate was 89.1%. Median follow-up duration was 7.9 years. The 10-year cumulative incidences of cardiac death in each degree of LVEF are shown in the Figure. Conclusions Successful recanalisation for chronic total occlusion lesions in patients with impaired LVEF may be associated with reduced cardiac mortality.


Sign in / Sign up

Export Citation Format

Share Document