scholarly journals The Comparison of Intraoperative Pressure Control and Volume Control Ventilation in Supine and Prone Positions: The Endless Debate

2021 ◽  
Vol 17 (4) ◽  
pp. 412-419
Author(s):  
Sinan Aşar ◽  
Furkan Tontu ◽  
Gülay Aşık Eren
2021 ◽  
Author(s):  
Emre Badur ◽  
Mustafa Altınay ◽  
Pınar Sayın ◽  
Ayşe Surhan Çınar ◽  
leyla türkoğlu ◽  
...  

Abstract Background: To compare the volume-controlled and pressure-controlled ventilation modes with near infrared spectroscopy (NIRS) cerebral oximetry and blood gas status in laparoscopic cholecystectomyMethods: Seventy patients (n=70), who underwent elective laparoscopic cholecystectomy operation were randomized into two groups (volume control ventilation - group V, pressure control ventilation - group P). Demographic data (age, gender, body mass index) and operative data (anesthesia, surgery, and insufflation durations) were recorded. Patients’ single derivation electrocardiogram, pulse oximetry, non-invasive arterial pressure, NIRS cerebral oximetry and end-tidal CO2 parameters were recorded. Measurements were done at the start of anesthesia (T0), at the end of intubation (T1), 5 minutes after the insufflation (T2), at the time just before desufflation (T3) and 5 minutes after desufflation (T4).The patients’ heart rate, systolic and diastolic arterial pressure, saturation of pulse oximetry, and NIRS values were recorded for time points. Additionally, arterial gas results and mechanical ventilation parameters were recorded as well. Results: No significant difference was found in age, sex, body mass index. Operation, anesthesia and insufflation durations were similar for the groups. In Group P, NIRS right T1-2-3 averages and NIRS left T2-3 averages were significantly higher than Group V (p=0.030, p=0.001, p=0.001, p=0.006, p=0.002 respectively). In Group P T1-T2-T4, mean peak pressures and mean plateau pressures were significantly lower than Group V (p=0.003, p=0.001, p<0.001, p=0.011, p=0.001, p<0.001 respectively).Conclusion: Mechanical ventilation that performed in pressure-control ventilation mode is resulted with better tissue oxygenation than volume-control ventilation mode. In pressure-control ventilation mode, peak pressure and plateau pressure were lower.Registration of study at ClinicalTrials.gov was made at 25/01/2021 with the NCT04723043 number.


2005 ◽  
Vol 22 (Supplement 34) ◽  
pp. 62
Author(s):  
E. Christidou ◽  
K. Spanopoulos ◽  
M. Nastou ◽  
B. Macrakis ◽  
E. Blougoura ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document