Decontamination efficacy of photon initiated photoacustic streaming (PIPS) of irrigants using low energy laser settings: an in vitro study

Author(s):  
E Pedulla ◽  
G Olivi ◽  
G Tempera ◽  
C Genovese ◽  
E Campagna ◽  
...  
2021 ◽  
pp. 088532822110195
Author(s):  
Moataz Elsisy ◽  
Mahdis Shayan ◽  
Yanfei Chen ◽  
Bryan W Tillman ◽  
Catherine Go ◽  
...  

Nitinol is an excellent candidate material for developing various self-expanding endovascular devices due to its unique properties such as superelasticity, biocompatibility and shape memory effect. A low-energy laser joining technique suggests a high potential to create various large diameter Nitinol endovascular devices that contain complex geometries. The primary purpose of the study is to investigate the effects of laser joining process parameters with regard to the mechanical and biocompatible performance of Nitinol stents. Both the chemical composition and the microstructure of the laser-welded joints were evaluated using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). In vitro study results on cytotoxicity demonstrated that the joining condition of 8 Hz frequency and 1 kW laser power showed the highest degree of endothelial cell viability after thermal annealing in 500°C for 30 min. Also, in vitro study results showed the highest oxygen content at 0.9 kW laser power, 8 Hz frequency, and 0.3 mm spot size after the thermal annealing. Mechanical performance test results showed that the optimal condition for the highest disconnecting force was found at 1 Hz frequency and 1 kW power with 0.6 mm spot size. Two new endovascular devices have been fabricated using the optimized laser joining parameters, which have demonstrated successful device delivery and retrieval, as well as acute biocompatibility.


1985 ◽  
Vol 10 (1) ◽  
pp. 35-39 ◽  
Author(s):  
J. Bossy ◽  
JM. Chevalier ◽  
P. Sambuc ◽  
R. Quatrefages

2018 ◽  
Vol 6 (4) ◽  
pp. 66 ◽  
Author(s):  
Rima Nejem Wakim ◽  
Melanie Namour ◽  
Hoang Nguyen ◽  
Andre Peremans ◽  
Toni Zeinoun ◽  
...  

Oral rehabilitation with dental implants has revolutionized the field of dentistry and has been proven to be an effective procedure. However, the incidence of peri-implantitis has become an emerging concern. The efficacy of the decontamination of the implant surface, by means of lasers, is still controversial. Previous studies have revealed a reduction in osteoblast adhesion to carbon-contaminated implant surfaces. This in-vitro study aimed to evaluate the decontamination of failed implants by assessing the carbon proportion, after irradiation by low-energy erbium yttrium-aluminum-garnet laser (Er:YAG) (Fotona; 2940 nm, Ljubljana, Slovenia) for a single and for multiple passages, until getting a surface, free of organic matters; to find the appropriate procedure for dental-implant surface-decontamination. Ninety implants were used. Thirty sterile implants were kept as a negative control. Thirty failed implants were irradiated by the Er:YAG laser, for a single passage, and the other thirty, for multiple passages. The parameters used in our experiments were an irradiation energy of 50 mJ, frequency of 30 Hz, and an energy density of 3.76 J/cm2. A sapphire tip, with a length of 8 mm, was used with concomitant water spray irrigation, under air 6 and water spray 4. Super short pulse mode (SSP) was of 50 μs; irradiation speed being 2 mm/s. We used energy-dispersive X-ray spectroscopy (EDX) to evaluate the carbon proportion on the surfaces of the sterile implants, the contaminated, and the lased implants, with one (LX1) and with three passages (LX3). Statistical analysis was performed by ANOVA. Results showed mean difference between the three groups (contaminated, LX1, and LX3) with p < 0.0001, as between LX1 and Group A (p < 0.0001), while the difference between LX3 and the control group was not statistically significant. The decontamination of the implant surfaces with a low-energy Er:YAG laser with three passages, appeared to be an encouraging approach.


Sign in / Sign up

Export Citation Format

Share Document