scholarly journals Clinical Results of Tibia Condylar Valgus Osteotomy Using Locking Plate System

2011 ◽  
Vol 60 (4) ◽  
pp. 734-738
Author(s):  
Hideya Kawamura ◽  
Yasuhide Urakami ◽  
Yasunari Urakami ◽  
Youichi Urakami ◽  
Tomotaro Yamaguchi ◽  
...  
2012 ◽  
Vol 61 (1) ◽  
pp. 76-80
Author(s):  
Toru Asakura ◽  
Naohito Oshima ◽  
Kunichika Shin ◽  
Kenjiro Ooe ◽  
Koumei Matsuura

2015 ◽  
Vol 28 (04) ◽  
pp. 288-293 ◽  
Author(s):  
T. Nicetto ◽  
M. Petazzoni

SummaryObjectives: To describe the use of the Fixin locking plate system for stifle arthrodesis in dogs and to retrospectively report the clinical and radiographic outcomes in six cases.[uni2028]Materials and methods: Medical records of dogs that had arthrodesis with the Fixin locking plate system were reviewed. For each patient, data pertaining to signalment and implant used were recorded. Plate series and thickness, number of screws placed, number of cortices engaged, and screw diameters were also recorded. The outcome was determined from clinical and radiographic followups. Radiographic outcomes assessed included the measurement of the postoperative femoral-tibial angle in the sagittal plane.Results: Six dogs met the inclusion criteria for the study. Mean body weight was 13 kg (range: 3 - 34 kg). Radiographic follow-up (mean: 32 weeks, range: 3 - 52 weeks) was available for all dogs. In one case, an intra-operative complication occurred. In another case, a tibial fracture occurred 20 days after surgery. All arthrodeses healed and no implant complication was detected although all cases had mechanical lameness.Clinical significance: Stifle arthrodesis can be performed successfully using a Fixin locking plate system.


2017 ◽  
Vol 28 (6) ◽  
pp. 1456-1461 ◽  
Author(s):  
Patiguli Wusiman ◽  
Julaiti Tuerxun ◽  
Buhiliqiemu Yaolidaxi ◽  
Adili Moming

Hand ◽  
2016 ◽  
Vol 12 (6) ◽  
pp. 561-567 ◽  
Author(s):  
Yoshihiro Abe ◽  
Susumu Tokunaga ◽  
Takuro Moriya

Background: The aim of this study was to compare the functional outcomes and complications of volar and dorsal plating for the management of intra-articular distal radius fractures, with special regard to indications for dorsal plating. Furthermore, we examine the rationale for choosing dorsal plating and its frequency of use. Methods: Clinical assessments included range of motion measurements at the wrist; grip strength; the Quick Disabilities of the Arm, Shoulder, and Hand score; and the Gartland and Werley score. Clinical results were compared with those achieved using a volarly placed locking plate system. According to Lutsky’s plate theory, the rationale for choosing dorsal plating was based on 4 types of pathologic fractures. Results: Of 112 patients, 38 patients were treated with open reduction internal fixation via a dorsal approach and 68 patients were treated using a volar approach. Except for wrist flexion, there were no other statistical differences in the clinical results between groups for both subjective and objective parameters. There were no statistically significant differences in the complication rates between the volar and dorsal plated groups. One serious complication occurred after volar plating. The most common reason for choosing dorsal plating was irreducible dorsal die-punch fractures. Conclusions: The treatment of displaced intra-articular distal radius fractures with a dorsally versus a volarly placed interlocking plate system demonstrated similar clinical results. Postoperative complications were not readily observed in the patients treated with a dorsal locking plate. Certain fracture patterns are more appropriately stabilized using a dorsal plate fixation.