Forensic Engineering Analysis By Plausible Inference - Case in Point: A Building Failure

Author(s):  
Lewis L. Zickel

A first floor resident of a seven-story multiple dwelling building complex, seated at his kitchen table, glanced out of the adjacent window at the moment the landscaped courtyard collapsed in a cloud of dust and escaping steam. It was early twilight on Christmas day. On its 1 I PM news broadcast, the local television network affiliate aired the story along with a press conference with a municipal building official. On the evening of the following day, the president of the Cooperative Board of Directors requested the writer to conduct a forensic engineering investigation to determine the cause of the collapse. At approximately the same time, the sponsor of the cooperative, acting independently, engaged a contractor to shore the surviving structure and to remove the debris from the collapse site.

Author(s):  
Richard Ziernicki ◽  
William Pierce ◽  
Angelos Leiloglou

This paper presents a case study involving an 8-lb “projectile” piece of concrete thrown from a phantom vehicle into the windshield of a semi-tractor truck, subsequently striking the driver’s (plaintiff’s) head. A witness told the investigating officer that the phantom vehicle was a white-rear dump truck similar to the trucks he’d seen coming in and out of a construction entrance at a nearby park. However, no follow-up investigation was conducted by investigative officers. The lead author was retained by the plaintiff’s attorney to follow up and investigate the witness’ observation of the phantom white-rear dump truck in an attempt to identify the probable source of the concrete projectile, locate the phantom vehicle, reconstruct the incident, and determine the probable cause of the incident. Several forensic engineering techniques were used during the forensic engineering investigation, including evidence analysis, photography, high-definition scanning, photogrammetry, evaluation of the accident timeline, physical testing, case study analysis, projectile analysis, and application of the process of elimination methodology. Through the forensic engineering analysis, the probable source of the projectile concrete was identified, the white-rear dump truck and driver were identified, the accident was reconstructed, and the probable cause of the accident was determined.


Author(s):  
Dwight Pfenning

A Forensic Engineering Analysis Was Performed Of The Motorcoach Fire That Took The Lives Of3 Houston Area Assisted Living Home Patients As They Were Being Evacuated To The Dallas Area Asurricane Rita Was Approaching The Texas Coast In 2005. The Motorcoach Was Engulfed In Flames Andmoke After A Tag Axle Tire Caught Fire On A Freeway Near Dallas. Our Analysis Included Testing With Extensive Instrumentation On An Exemplar Motorcoach In Order To Determine How The Fire Developed And Entered The Passenger Compartment. Included In The Analysis Was The Contribution To The Fire From The Patients Onboard Oxygen Bottles. The Use Of Alternate Materials Was Tested For Their Effect On The Time For Safe Egress.


Author(s):  
D.S. Sax Saxena ◽  
Saxena Anu

The Influence Of Construction And Pile Driving Vibrations On Surrounding Buildings, Including Hospitals And Eye Examination Facilities, Sensitive Devices Such As Computers And Surgical Microscopes Or Electronic Machines, And People In The Urban Environment Is A Significant Consideration In Obtaining Project Approvals From Appropriate Agencies And Authorities. Implementation Of Construction Projects In Areas Adjacent To Existing Buildings (Aged, Historical, Residential, Commercial, Industrial, Medical Services, Or Electronic Services) Creates Additional Difficulties. Specialized Case History Is Presented Where Damage To Sensitive Structures From A Variety Of Vibratory Construction Methods Ranging From Pile Driving, Highway Construction, Rock Excavation And/Or Blasting, Was Considered. Twenty Homeowners From A Residential Subdivision In The Florida Panhandle, Claimed Damage Including Cracking To Their Properties During Construction Of Various Portions Of City Storm Water Treatment/Enhancement Project. It Was Also Alleged That During Excavation And Construction Of Drainage Structures, Especially Four Subsurface Treatment Vaults That Required Installation And Extraction Of Sheet Piles Using Vibratory Hammer, Stability Of The Nearby Residential Structures Was Endangered And Resulted In Movement/Cracking. Forensic Engineering Analysis Was Effectively Utilized To Identify, Investigate, And Remediate The Concerns As Well As Assist In Litigation And In Some Cases Avoidance. This Technical Paper Presents Some Legal Issues Related To Litigation, Mediation, And Resolution Involving Jurisprudence System And Introduces A Case History That Includes All Elements Of Forensic Engineering.


Author(s):  
William R. Broz

A Below-Grade, Nps 12 Pipeline Serving A Major Commercial Marine Terminal Failed At A Flanged Joint, Causing A Major Leak And Contamination Of The Surrounding Soil. The Gasket At The Failed Joint Showed Evidence Of Localized, Radial Through-Leakage. At The Terminal, The Initial Excavation Of Contaminated Soil Caused Minor Damage To Several Non-Leaking Segments Of Pipe And The Author Was First Tasked To Oversee The Related Inspection, Weld Repair And Corrosion Protection Work. The Author Subsequently Performed A Forensic Pipe Stress Analysis Of The Affected Portion Of The Fuel Oil System Per The Governing Pressure Piping Code. The Results Indicated That The Leaking Joint Failed With Respect To The Code Criterion Of Equivalent Pressure. Further Investigation Revealed That The System As Originally Designed Was Entirely Of Butt Weld Construction With No Flanged Joints, And Would Have Complied With All Code Requirements. The Investigation Determined That The General Contractor Had Made An Unauthorized Substitution Of Flanged Joints For Butt Weld Joints, Without Informing The Owner Or Design Engineer Of Record.


Author(s):  
Robert N. Anderson

Zinc-Rich Brasses With The Zinc Content Above 30% Can Be Involved In Corrosion Processes With Catastrophic Results. The Dezincification Results In A Low Strength Copper With A Porous Sponge Like Structure. The Case, Where Dezincification Occurred With Massive Impact, Involved 34,000 New Homes In An Urban Location In Nevada. These Homes Were Constructed Using Building Code Approved Plastic Pex Tubing For Plumbing With Brass Fittings. Leaks Developed In The Home Plumbing Systems After Approximately 3-6 Years. This Failure Resulted In Lawsuits Involving Home Owner Associations, Insurance Companies, Contractors, Plumbers, Architects, Manufacturers, And Suppliers.


Author(s):  
Curtis E. Falany

Lightning Is A Powerful And Dangerous Natural Force. It Is Capable Of Inflicting Significant Damage To Our Environment And Causing Injury Or Death In Living Organisms. Electrical And Electronic Circuits Are Particularly Susceptible To Lightning, Both From Direct Strikes And From Lightning Induced Electrical Surges. Fires Often Result From Lightning Strikes. Injury And Death Can Result From Both Direct Strikes, Lightning Induced Electrical Surges, And Indirectly From Structure Damage And Fires. The Insurance In-Dustry Offers Coverage For Lighting Related Losses And A Forensic Engineer Is Often Consulted To Assist In Adjusting The Claim.