The Effect of Right Ventricular Apical Pacing on Asynchrony Parameters in Different Heart Rates Detected by Tissue Doppler Imaging in Patients with Permanent Pacemaker

2021 ◽  
Author(s):  
Erdem Türkyilmaz ◽  
Taylan Akgün ◽  
Mehmet Mustafa Can ◽  
İbrahi̇m Hali̇l Tanboğa ◽  
Can Yücel Karabay ◽  
...  
CHEST Journal ◽  
2009 ◽  
Vol 136 (4) ◽  
pp. 31S
Author(s):  
Usman Javed ◽  
Vijay Balasubramanian ◽  
Ralph J. Wessel ◽  
Sandra Legarreta ◽  
John A. Ambrose ◽  
...  

2007 ◽  
Vol 24 (5) ◽  
pp. 485-493 ◽  
Author(s):  
Alparslan Birdane ◽  
Cengiz Korkmaz ◽  
Necmi Ata ◽  
Yuksel Cavusoglu ◽  
Timucin Kasifoglu ◽  
...  

2017 ◽  
Vol 27 (6) ◽  
pp. 1186-1193 ◽  
Author(s):  
Holly Nadorlik ◽  
Corey Stiver ◽  
Sairah Khan ◽  
Yongjie Miao ◽  
Ralf Holzer ◽  
...  

AbstractBackgroundNewer echocardiographic techniques may allow for more accurate assessment of right ventricular function. Adult studies have correlated these echocardiographic measurements with invasive data, but minimal data exist in the paediatric congenital heart population. The purpose of this study was to evaluate echocardiographic measurements that correlate best with right ventricular systolic and diastolic catheterisation parameters.MethodsPatients with two-ventricle physiology who underwent simultaneous echocardiogram and cardiac catheterisation were included in this study. Right ventricular systolic echocardiographic data included fractional area change, displacement, tissue Doppler imaging s’ wave, global longitudinal strain, and strain rate s’ wave. Diastolic echocardiographic data included tricuspid E and A waves, tissue Doppler imaging e’ and a’ waves, and strain rate e’ and a’ waves. E/tissue Doppler imaging e’, tissue Doppler imaging e’/tissue Doppler imaging a’, E/strain rate e’, and strain rate e’/strain rate a’ ratios were also calculated. Catheterisation dP/dt was used as a marker for systolic function and right ventricular end-diastolic pressure for diastolic function.ResultsA total of 32 patients were included in this study. The median age at catheterisation was 3.1 years (0.3–17.6 years). The DP/dt was 493±327 mmHg/second, and the right ventricular end-diastolic pressure was 7.7±2.4 mmHg. There were no significant correlations between catheterisation dP/dt and systolic echocardiographic parameters. Right ventricular end-diastolic pressure correlated significantly with strain rate e’ (r=−0.4, p=0.02), strain rate a’ (r=−0.5, p=0.03), and E/tissue Doppler imaging e’ (r=0.4, p=0.04).ConclusionCatheterisation dP/dt did not correlate with echocardiographic measurements of right ventricular systolic function. Strain rate and tissue Doppler imaging analysis significantly correlated with right ventricular end-diastolic pressure. These values should be further studied to determine whether they may be used as an alternative method to estimate right ventricular end-diastolic pressure in this patient population.


Sign in / Sign up

Export Citation Format

Share Document