scholarly journals Supplementary material to "MULTICHARME: A modified Chernin-type multi-pass cell designed for IR and THz long-path absorption measurements in the CHARME atmospheric simulation chamber"

Author(s):  
Jean Decker ◽  
Éric Fertein ◽  
Jonas Bruckhuisen ◽  
Nicolas Houzel ◽  
Pierre Kulinski ◽  
...  
2019 ◽  
Author(s):  
Michael Rolletter ◽  
Martin Kaminski ◽  
Ismail-Hakki Acir ◽  
Birger Bohn ◽  
Hans-Peter Dorn ◽  
...  

2021 ◽  
Author(s):  
Jean Decker ◽  
Éric Fertein ◽  
Jonas Bruckhuisen ◽  
Nicolas Houzel ◽  
Pierre Kulinski ◽  
...  

Abstract. We have developed MULTICHARME, a modified Chernin-type multi-pass cell especially designed for IR and THz long-path absorption measurements in the CHamber for Atmospheric Reactivity and Metrology of the Environment (CHARME). By measuring the output power using a near-IR diode-laser and a THz amplified multiplication chain, we have established that the effective reflectivity of MULTICHARME is better than 94 % over approximately three decades of frequency. Absorption measurements of N2O have been performed by probing highly excited rovibrational transitions in the near-IR and ground state rotational transitions at submillimetre wavelengths. In each case the linearity of the absorbance with the pathlengths was verified. Finally, we demonstrate that THz spectroscopy is able to study the isotopic composition of greenhouse polar gases such as N2O and to absolutely quantify stable (N2O) and reactive (O3) species at trace levels. Moreover, a THz monitoring at low pressure of the ozone decay in the chamber has been performed. The deduced ozone lifetime of 3.4 ± 0.1 h is shorter compared with previous measurements performed in CHARME at atmospheric pressure. For the first time, the ability of THz rotational spectroscopy to monitor, with a very high degree of selectivity, stable and reactive polar compounds at trace level in an atmospheric simulation chamber is demonstrated. However, the sensitivity of the THz monitoring needs to be improved to reach the atmospheric trace levels. For this purpose, it is necessary to figure out the baseline variations as well as possible induced by the multiple standing waves present in MULTICHARME.


2017 ◽  
Author(s):  
Hendrik Fuchs ◽  
Anna Novelli ◽  
Michael Rolletter ◽  
Andreas Hofzumahaus ◽  
Eva Y. Pfannerstill ◽  
...  

2021 ◽  
Author(s):  
Marcel Snels ◽  
Stefania Stefani ◽  
Angelo Boccaccini ◽  
David Biondi ◽  
Giuseppe Piccioni

Abstract. A novel simulation chamber PASSxS (Planetary Atmosphere Simulation System for Spectroscopy) has been developed for absorption measurements performed with a Fourier Transform Spectrometer (FTS) and, possibly, a cavity ring down (CRD) spectrometer, with a sample temperature ranging from 100 K up to 550 K, while the pressure of the gas can be varied from 10 mbar up to 60 bar. These temperature and pressure ranges cover a significant part of the planetary atmospheres in the solar system and the absorption chamber can thus be used to simulate planetary atmospheres of solar planets and extra solar planets with similar atmospheres. The optical absorption path for the FTS absorption measurements is 3.2 m, due to the implementation of a multipass setup inside the chamber. The FTS measurements cover a wide spectral range, from the visible to the mid-infrared with a sensitivity sufficient for medium strength absorption bands. The FTS has been used previously to measure high pressure atmospheres, including collision induced absorption bands and continuum absorption at ambient temperatures. PASSxS allows to measure the temperature dependence of collision induced bands and continuum absorption, which is important both for the modelling of planetary atmospheres as well as for fundamental processes involving collisions between molecules and atoms.