Validation of a Virtual Reality Simulator for Percutaneous Pedicle Screw Insertion

Author(s):  
Alexander Charalambous ◽  
Neil Segaren ◽  
Anil Segaren ◽  
Kalpesh Vaghela ◽  
Syed Aftab ◽  
...  

Introduction: Working-hour restrictions, rota gaps and an increasing drive for theatre efficiency have resulted in challenges to surgical training. As a result, Virtual Reality (VR) has emerged as a popular tool to augment this training. Our aim was to evaluate the validity of a VR simulator for performing percutaneous pedicle screw guidewire insertion. Materials and Methods: Twenty-four participants were divided into three equal groups depending on prior surgical experience: a novice group (<10 procedures), an intermediate group (10-50 procedures) and an expert group (>50 procedures). All subjects performed four guidewire insertions on a TraumaVision® simulator (Swemac Innovation AB, Linköping, Sweden) in a set order. Six outcome measures were recorded; total score, time, fluoroscopy exposure, wire depth, zone of placement and wall violations. Results: There were statistically significant differences between the groups for time taken (p<0.001) and fluoroscopy exposure (p<0.001). The novice group performed the worst, and the expert group outperformed both intermediates and novices in both categories. Other outcome results were good and less variable. There was an observed learning effect in the novice and intermediate groups between each of the attempts for both time taken and fluoroscopy exposure. Conclusions: The study contributes constructive evidence to support the validity of the TraumaVision® simulator as a training tool for pedicle screw guidewire insertion. The simulator is less suitable as an assessment tool. The learning effect was evident in the less experienced groups, suggesting that VR may offer a greater benefit in the early stages of training. Further work is required to assess transferability to the clinical setting.

2010 ◽  
Vol 13 (4) ◽  
pp. 509-515 ◽  
Author(s):  
Cary Idler ◽  
Kevin W. Rolfe ◽  
Josef E. Gorek

Object This study was conducted to assess the in vivo safety and accuracy of percutaneous lumbar pedicle screw placement using the owl's-eye view of the pedicle axis and a new guidance technology system that facilitates orientation of the C-arm into the appropriate fluoroscopic view and the pedicle cannulation tool in the corresponding trajectory. Methods A total of 326 percutaneous pedicle screws were placed from L-3 to S-1 in 85 consecutive adult patients. Placement was performed using simple coaxial imaging of the pedicle with the owl's-eye fluoroscopic view. NeuroVision, a new guidance system using accelerometer technology, helped align the C-arm trajectory into the owl's-eye view and the cannulation tool in the same trajectory. Postoperative fine-cut CT scans were acquired to assess screw position. Medical records were reviewed for complications. Results Five of 326 screws breached a pedicle cortex—all breaches were less than 2 mm—for an accuracy rate of 98.47%. Five screws violated an adjacent facet joint. All were at the S-1 superior facet and included in a fusion. No screw violated an adjacent mobile facet or disc space. There were no cases of new or worsening neurological symptoms or deficits for an overall clinical accuracy of 100%. Conclusions The owl's-eye technique of coaxial pedicle imaging with the C-arm fluoroscopy, facilitated by NeuroVision, is a safe and accurate means by which to place percutaneous pedicle screws for degenerative conditions of the lumbar spine. This is the largest series reported to use the oblique or owl's-eye projection for percutaneous pedicle screw insertion. The accuracy of percutaneous screw insertion with this technique meets or exceeds that of other reported clinical series or techniques.


2017 ◽  
Vol 43 (2) ◽  
pp. E9 ◽  
Author(s):  
Brandon W. Smith ◽  
Jacob R. Joseph ◽  
Michael Kirsch ◽  
Mary Oakley Strasser ◽  
Jacob Smith ◽  
...  

OBJECTIVEPercutaneous pedicle screw insertion (PPSI) is a mainstay of minimally invasive spinal surgery. Traditionally, PPSI is a fluoroscopy-guided, multistep process involving traversing the pedicle with a Jamshidi needle, placement of a Kirschner wire (K-wire), placement of a soft-tissue dilator, pedicle tract tapping, and screw insertion over the K-wire. This study evaluates the accuracy and safety of PPSI with a simplified 2-step process using a navigated awl-tap followed by navigated screw insertion without use of a K-wire or fluoroscopy.METHODSPatients undergoing PPSI utilizing the K-wire–less technique were identified. Data were extracted from the electronic medical record. Complications associated with screw placement were recorded. Postoperative radiographs as well as CT were evaluated for accuracy of pedicle screw placement.RESULTSThirty-six patients (18 male and 18 female) were included. The patients’ mean age was 60.4 years (range 23.8–78.4 years), and their mean body mass index was 28.5 kg/m2 (range 20.8–40.1 kg/m2). A total of 238 pedicle screws were placed. A mean of 6.6 pedicle screws (range 4–14) were placed over a mean of 2.61 levels (range 1–7). No pedicle breaches were identified on review of postoperative radiographs. In a subgroup analysis of the 25 cases (69%) in which CT scans were performed, 173 screws were assessed; 170 (98.3%) were found to be completely within the pedicle, and 3 (1.7%) demonstrated medial breaches of less than 2 mm (Grade B). There were no complications related to PPSI in this cohort.CONCLUSIONSThis streamlined 2-step K-wire–less, navigated PPSI appears safe and accurate and avoids the need for radiation exposure to surgeon and staff.


2009 ◽  
Vol 58 (2) ◽  
pp. 156-160
Author(s):  
Masayuki Nakahara ◽  
Kenki Nishida ◽  
Koichi Ogawa ◽  
Kenichiro Hanabusa ◽  
Yuichi Takahashi ◽  
...  

2008 ◽  
Vol 17 (6) ◽  
pp. 857-863 ◽  
Author(s):  
W. Lehmann ◽  
A. Ushmaev ◽  
A. Ruecker ◽  
J. Nuechtern ◽  
L. Grossterlinden ◽  
...  

Author(s):  
Alsiagy A. Salama ◽  
Mohamed A. Amin ◽  
Ahmed Y. Soliman ◽  
Ahmed El-Tantaway

Abstract Background Pedicle screw instrumentation is used widely in lumbar spine for stabilization to enhance arthrodesis and has been accepted in the thoracic spine in recent years. The purpose of this study was to assess the value of postoperative 320 multi-slice computed tomography (MSCT) in assessment of pedicle screw placement in patients with spinal fixation with clinical and surgical correlation. Results A total of 340 pedicular screws were inserted to 70 cases. 286 (84.12%) were in, 54 screws (15.88%) were violated, and revision surgeries were required for 5 displaced screws. On axial, coronal reconstruction and three-dimensional (3D) reformatted CT images 36, 47, and 54 displaced screws were detected, respectively. Both sensitivity and specificity for 3D reformatted images were 100%. For axial image, they were 97.6% and 89.4%, respectively, compared with surgical findings in 5 revised screws. Conclusion Multi-slice CT scan is a valuable and valid postoperative assessment tool of accuracy of spinal pedicle screw placement.


Sign in / Sign up

Export Citation Format

Share Document