RAPID HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF RALTEGRAVIR IN HUMAN SALIVA

INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (09) ◽  
pp. 68-73
Author(s):  
K Vijaya Sri ◽  
M. Shiva Kumar ◽  
M. A. Madhuri ◽  
Suresha K. ◽  

In this study, a high-performance liquid chromatographic method (HPLC) was developed, validated and applied for the determination of raltegravir in biological sample like saliva. Liquid- liquid extraction was performed for isolation of the drug and elimination of saliva interferences. Samples of saliva was extracted with 50µL of ortho phosphoric acid and 3ml of methanol was added and spiked with raltegravir. The chromatographic separation was performed on Agilent Eclipse C18 (100 mm × 4.6 mm, 3.5µm) column, by using 80:20 v/v acetonitrile: water as a mobile phase under isocratic conditions at a flow rate of 1.0 mL/min for UV detection at 240 nm. Retention time of raltegravir was found to be 1.030 min. Linearity was found to be in the range of 25-1000 ng/mL with regression equation y = 13864x + 40495 and correlation coefficient 0.999. The low % RSD value indicates the method is accurate and precise. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.76 and 2.28 ng/mL, respectively. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for determination of raltegravir in saliva.

INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (10) ◽  
pp. 56-62
Author(s):  
A Anerao ◽  
◽  
V. Dighe ◽  
A Gupta ◽  
C. Patil ◽  
...  

N-Methylethanolamine is the side chain of the drug diphenhydramine hydrochloride. A sensitive high performance liquid chromatography method with pre-column derivatization was developed and validated for the determination of N-methylethanolamine impurity in diphenhydramine hydrochloride active pharmaceutical ingredient. HPLC method on column Cosmosil MS-II, C-18, 250 mm X 4.6 mm, particle size 5 μm with UV detector was used. The proposed method is specific, linear, accurate, rugged and precise. The calibration curves showed good linearity over the concentration range of 0.03 mg/g to 1.5 mg/g and the correlation coefficient was 0.999. Method had very low limit of detection (LOD) and limit of quantification (LOQ) as 0.01 mg/g and 0.03 mg/g, respectively, of the analyte. Accuracy was observed within 94.4% to 96.2%.


2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Sergio del Rio-Sancho ◽  
César E. Serna-Jiménez ◽  
M. Aracely Calatayud-Pascual ◽  
Cristina Balaguer-Fernández ◽  
Andrés Femenía-Font ◽  
...  

The purpose of the present work was to validate an accurate and precise high-performance liquid chromatography (HPLC) method involving ultraviolet detection for the quantitative analysis of memantine hydrochloride. In order to analyze a molecule with no chromophoric groups that could be detected by a UV/visible detector, it was necessary to extract the drug and to perform a dansylation reaction that enabled the UV/visible detection of the derivatized molecule. Separation was carried out with a 150 mm Kromasil C18 column at room temperature. The detection response, at 218 nm, was found to be linear in the concentration range from 0.5 to 50 μg/mL. The method was validated for specificity, linearity, precision, accuracy, limit of detection, limit of quantification, and robustness. The limit of detection (LOD) was 0.144 μg/mL, and the limit of quantification (LOQ) was 0.437 μg/mL. The dansylated memantine complex was stable for at least five days in all the conditions evaluated. The potential use of this method has been demonstrated by the quantification of memantine hydrochloride contained in samples from the study of itsin vitrotransdermal permeation.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (07) ◽  
pp. 32-37
Author(s):  
Vijaya Lakshmi Marella ◽  
Chaitanya S. N ◽  

A selective and sensitive reverse phase High Performance Liquid Chromatographic method has been developed and validated for the estimation of lornoxicam in bulk, pharmaceutical dosage forms and in dissolution samples. The analysis was performed isocratically on an Inertsil column (250* 4.6 mm, 5 µm) using a mass spectrometric compatible mobile phase of 10 mM ammonium acetate: acetonitrile (50:50 V/V) at a flow rate of 1 mL/min.The detection wavelength was 290 nm. The retention time was found to be 4.573 min for lornoxicam. The linearity of the method has been satisfied with Beer Lambert’s law in the concentration range of 5-25 µg/mL with a correlation coefficient of 0.9988. The mean recoveries assessed for lornoxicam were in the range of 100.39-101.86 %, indicating good accuracy of the method. The limit of detection and limit of quantification were found to be 0.03 and 0.11 µg/mL, respectively. The developed method has been statistically validated in accordance with ICH guidelines and found to be mass spectrometric compatible, simple, precise, and accurate with the prescribed values. Thus, the proposed method was successfully applied for the estimation of lornoxicam in routine quality control analysis of bulk, formulations and in dissolution samples.


INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (05) ◽  
pp. 48-52
Author(s):  
A Lodhi ◽  
◽  
A Jain ◽  
B. Biswal

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase ODS, 5µm (250×4.6) mm column. The mobile phase consisted of acetonitrile: buffer (60:40 V/V) at a flow rate of 0.5 mL/min. The PDA-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 1.5 – 12.5 µg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quantification were 0.0540513 and 0.1637919 µg/mL respectively.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.


2018 ◽  
Vol 2018 ◽  
pp. 1-5 ◽  
Author(s):  
Ahmed Salem Sebaei ◽  
Ahmed M. Gomaa ◽  
A. A. El-Zwahry ◽  
E. A. Emara

Formaldehyde is one of the most dangerous chemical compounds affecting the human health; exposure to it from food may occur naturally or by intentional addition. In this study a high performance liquid chromatography method for determination of formaldehyde in dairy products was described. The dairy samples were reacted and extracted with a warmed organic solvent in the presence of derivatizing agent 2,4-dinitrophenylhydrazine (DNPH) and formaldehyde; the mixture was centrifuged and followed by diode array detection. The method is validated and gives average recovery of formaldehyde at the three different levels 0.1, 5.0, and 10.0 mg/kg varied between 89% and 96%. The method is linear from the limit of quantification 0.1 mg/kg up to 10 mg/kg levels. This method is intended for formaldehyde analyses in dairy products simply with stable derivatization, minimum residue loss, excellent recovery, and accurate results with a sensitive limit of detection 0.01 mg/kg. 90 dairy samples from milk, cheese, and yogurt were investigated from seven Egyptian governorates and all samples were free from formaldehyde.


2013 ◽  
Vol 9 (2) ◽  
pp. 26-29 ◽  
Author(s):  
AK Hemanth Kumar ◽  
V Sudha ◽  
Geetha Ramachandran

A high performance liquid chromatographic method for determination of rifabutin in human plasma was  developed. The method involved deproteinisation of the sample with acetonitrile and analysis of the  supernatant using a reversed-phase C18 column (250mm) and UV detection at a wavelength of 265nm.  The assay was specific for rifabutin and linear from 0.025 to 10.0μg/ml. The relative standard deviation  of intra- and inter-day assays was lower than 10%. The method was able to remove interfering materials  in plasma, yielding an average recovery of rifabutin from plasma of 101%. Due to its simplicity, the assay  can be used for pharmacokinetic studies of rifabutin. SAARC Journal of Tuberculosis, Lung Diseases & HIV/AIDS; 2012; IX(2) 26-29 DOI: http://dx.doi.org/10.3126/saarctb.v9i2.7975


Author(s):  
Gudipally. Mounika ◽  
K. Bhavya Sri ◽  
R. Swethasri ◽  
M. Sumakanth

To develop an accurate, precise, specific high performance liquid chromatography method for quantification of Canagliflozin in bulk and dosage forms. A C18 column (250mm X 4.6mm; 5μm phenomenex) was used with mobile phase containing Acetonitrile-0.1% sodium acetate buffer (pH-4.6), (20:80) in isocratic mode. The flow rate maintained was 1.0ml/min and the U.V detector was operated at 291nm. The retention time of Canagliflozin was 3.307min and showed a good linearity in concentration range of 2-14μg/ml with correlation coefficient of 0.999. The average percent recovery was found to be 99.98%. The developed method follows validation parameters such as system suitability, linearity, precision, accuracy, limit of detection and limit of quantification and robustness as per ICH guidelinesQ2(R1). The proposed method was found to provide faster retention time with sharp resolution with linearity at a lowest concentration as compared to previous methods and this method is validated as per International conference on harmonization guidelines and successfully applied for bulk and pharmaceutical dosage form.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
S. Sowjanya ◽  
Ch. Devadasu

A reverse phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for simultaneous estimation of levamisole and albendazole in drug substance and in its combinational dosage form. The analysis was carried out usingInertsil ODSC18(4.6 x 150 mm, 5μm) column, and the separation was carried out using a mobile phase containing a buffer of pH 3.5 and acetonitrile (70:30 v/v) pumped at a flow rate of 1.0 mL/min with variable wavelength UV-detection at 224 nm. Both the drugs were well resolved in the stationary phase and the retention times were 2.350 min and 4.055 for levamisole and albendazole, respectively. The method was validated and shown to be linear in the concentration range of 15-45μg/ml and 40-120μg/ml for levamisole and albendazole, respectively. The limit of detection (LOD) and limit of quantification (LOQ) were determined based on standard deviation of the y-intercept and the slope of the calibration curve. LOD and LOQ values were 2.08μg/ml and 6.03μg/ml for levamisole and 3.15μg/ml and 10.40μg/ml for albendazole, respectively. The accuracy of the method was assessed by adding known amount of standard solution (75 %, 100 %, and 125% of the sample concentration) to the preanalyzed sample solution of 100% concentration. All the samples were prepared and analyzed in triplicate. The percentage mean recovery by standard addition experiments of levamisole and albendazole is 99.66% and 98.73%, respectively.


2011 ◽  
Vol 8 (4) ◽  
pp. 1958-1964 ◽  
Author(s):  
H. R. Prajapati ◽  
P. N. Raveshiya ◽  
J. M. Prajapati

A reversed phase high performance liquid chromatographic (RP–HPLC) method was developed and subsequently validated for the determination of atomoxetine hydrochloride in bulk and pharmaceutical formulation. The separation was done by a PerkinElmer Brownlee analytical C8 column (260 mm x 4.6 mm, 5 µm) using methanol: 50 mM KH2PO2buffer (PH adjusted to 6.8 with 0.1 M NaOH), 80:20 v/v as an eluent. UV detection was performed at 270 nm at a flow rate 1.0 mL/min. The validation of the method was performed, and specificity, reproducibility, precision accuracy and ruggedness were confirmed. The correlation coefficient was found to be 0.997 for atomoxetine hydrochloride. The recovery was in the range of 99.94 to 100.98% and limit of quantification was found to be 5.707 µg/mL. The method is simple, rapid, selective and economical too and can be used for the routine analysis of drug in pharmaceutical formulations.