SIMULTANEOUS DETERMINATION OF FROVATRIPTAN, ALMOTRIPTAN AND ZOLMITRIPTAN IN COMBINED PHARMACEUTICAL DOSAGE FORM BY RP-HPLC METHOD

INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.

INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (05) ◽  
pp. 48-52
Author(s):  
A Lodhi ◽  
◽  
A Jain ◽  
B. Biswal

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase ODS, 5µm (250×4.6) mm column. The mobile phase consisted of acetonitrile: buffer (60:40 V/V) at a flow rate of 0.5 mL/min. The PDA-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 1.5 – 12.5 µg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quantification were 0.0540513 and 0.1637919 µg/mL respectively.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (07) ◽  
pp. 32-37
Author(s):  
Vijaya Lakshmi Marella ◽  
Chaitanya S. N ◽  

A selective and sensitive reverse phase High Performance Liquid Chromatographic method has been developed and validated for the estimation of lornoxicam in bulk, pharmaceutical dosage forms and in dissolution samples. The analysis was performed isocratically on an Inertsil column (250* 4.6 mm, 5 µm) using a mass spectrometric compatible mobile phase of 10 mM ammonium acetate: acetonitrile (50:50 V/V) at a flow rate of 1 mL/min.The detection wavelength was 290 nm. The retention time was found to be 4.573 min for lornoxicam. The linearity of the method has been satisfied with Beer Lambert’s law in the concentration range of 5-25 µg/mL with a correlation coefficient of 0.9988. The mean recoveries assessed for lornoxicam were in the range of 100.39-101.86 %, indicating good accuracy of the method. The limit of detection and limit of quantification were found to be 0.03 and 0.11 µg/mL, respectively. The developed method has been statistically validated in accordance with ICH guidelines and found to be mass spectrometric compatible, simple, precise, and accurate with the prescribed values. Thus, the proposed method was successfully applied for the estimation of lornoxicam in routine quality control analysis of bulk, formulations and in dissolution samples.


2013 ◽  
Vol 2 (2) ◽  
pp. 60-69 ◽  
Author(s):  
G Krishnaveni ◽  
PVV Sathyannarayana

A simple, rapid reverse phase high-performance liquid chromatographic method was developed and validated for the simultaneous estimation of Ezetimibe and Simvastatin in bulk and pharmaceutical dosage forms. Chromatography was carried out by using Chromosil C-18,column having 250 x 4.6mm internal diameter with a mixture of Methanol:Acetonitrile:0.1%Orthophosphoric Aid in the ratio of 75:20:05 (v/v/v) as mobile phase. Determination of the different analytical parameters such as linearity, precision, accuracy, and specificity, limit of detection (LOD) and limit of quantification (LOQ) was done. The calibration curve was found to be linear for each analyte in the desired concentration range. The average recovery was found to be 99.88 and 100.12 for Ezetimibe and Simvastatin respectively. The proposed method is highly sensitive, precise and accurate, which was evident from the LOD value of 1.2ppm and 0.25ppm for Ezetimibe and Simvastatin respectively and hence the present method can be applied successfully for the quantification of active pharmaceutical ingredient (API) content in the combined formulations of Ezetimibe and Simvastatin. DOI: http://dx.doi.org/10.3329/ijpls.v2i2.15450 International Journal of Pharmaceutical and Life Sciences Vol.2(2) 2013: 60-69


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
S. Sowjanya ◽  
Ch. Devadasu

A reverse phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for simultaneous estimation of levamisole and albendazole in drug substance and in its combinational dosage form. The analysis was carried out usingInertsil ODSC18(4.6 x 150 mm, 5μm) column, and the separation was carried out using a mobile phase containing a buffer of pH 3.5 and acetonitrile (70:30 v/v) pumped at a flow rate of 1.0 mL/min with variable wavelength UV-detection at 224 nm. Both the drugs were well resolved in the stationary phase and the retention times were 2.350 min and 4.055 for levamisole and albendazole, respectively. The method was validated and shown to be linear in the concentration range of 15-45μg/ml and 40-120μg/ml for levamisole and albendazole, respectively. The limit of detection (LOD) and limit of quantification (LOQ) were determined based on standard deviation of the y-intercept and the slope of the calibration curve. LOD and LOQ values were 2.08μg/ml and 6.03μg/ml for levamisole and 3.15μg/ml and 10.40μg/ml for albendazole, respectively. The accuracy of the method was assessed by adding known amount of standard solution (75 %, 100 %, and 125% of the sample concentration) to the preanalyzed sample solution of 100% concentration. All the samples were prepared and analyzed in triplicate. The percentage mean recovery by standard addition experiments of levamisole and albendazole is 99.66% and 98.73%, respectively.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (01) ◽  
pp. 20-25
Author(s):  
S. M Samyuktha ◽  
◽  
P. G Prasanthi ◽  
K Mahesh ◽  
B. N Nalluri ◽  
...  

A simple, selective, accurate High Performance Liquid Chromatographic (HPLC) method was developed and validated for the analysis of Fenspiride hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved isocratically using a C18 reverse phase column [Inertsil C18 column (250×4.6mm, 5μm)] utilizing a mobile phase containing 10mM Ammonium acetate: Acetonitrile (50:50 v/v) at a flow rate of 1 mL/min. The eluents were monitored at wavelength of 210 nm for a run time of 7 minutes at ambient temperature. The average retention time of the drug was found to be 4.6 minutes. The developed method was validated as per ICH guidelines to ascertain the reproducibility of the method. The method was found to be linear in the concentration range of 10-50 μg/mL with a good correlation coefficient of 0.998. The limit of detection (LOD) and limit of quantification (LOQ) were 0.007 and 0.021 μg/mL and the percentage recovery and assay were found to be 99.315 and 98.97%. Specificity with placebo by 3 D plots showed that the method was specific and free from interfering substances. Therefore, the fully validated method was good enough to carry out routine analysis of Fenspiride in bulk and tablet formulations.


2020 ◽  
Vol 11 (4) ◽  
pp. 7878-7884
Author(s):  
Gunturu Raviteja ◽  
Kantipudi Rambabu

With the quantitative analysis of Cidofovir and Famciclovir using a Symmetry C-18 150x4.6mm, 3.5 column with a flow rate of 1ml/min, a novel, quick, and accurate high performance liquid chromatographic method have been developed. The buffer is made up of 1 mL formic acid dissolved in 1 litre HPLC water, and the mobile step is made up of a 60:40 mixture of two components: Buffer and Acetonitrile. The detection was done at a wavelength of 250nm. With 8 minutes of run time, the Cidofovir and Famciclovir peaks were split, with the Cidofovir peak eluted at 2.8 minutes and the Famciclovir peak eluted at 6.4 minutes, respectively. In the concentration ranges of 7.5 g/ml to 112.5 g/ml for Cidofovir and 25 g/ml to 375 g/ml for Famciclovir, the proposed method shows strong linearity. The results of the precision and recovery studies range from 98 to 102 percent. The percent RSD in all robustness conditions is less than 2.0 percent. In stressful conditions, deterioration has a limited impact, and solutions remain stable for 24 hours. The parameters of precision, accuracy, specificity, stability, robustness, linearity, limit of detection, and limit of quantification were evaluated and found to be within the appropriate range when the method was developed and validated according to ICH guidelines.


Author(s):  
Bhupender Tomar ◽  
Ankita Sharma ◽  
Inder Kumar ◽  
Sandeep Jain ◽  
Pallavi Ahirrao

A simple, precise, and accurate reverse phase high performance liquid chromatographic method (RP-HPLC) was developed and validated for the estimation of the combination of 5- Fluorouracil (5-FU) and Imiquimod in active pharmaceutical ingredients (APIs). The method was carried out on Phenomenex C18 (250 × 4.6mm I.D., 5𝜇m) using isocratic elution mode. The mobile phase was used as Acetonitrile: 10mM potassium dihydrogen orthophosphate: triethylamine (40:59.9:0.1, v/v, pH 4.5 with orthophosphoric acid) and Water: ACN (50:50 v/v) was used as a diluent. The concentration of solvents was 1-20µg/ml and the volume of injection was 20µl with the flow rate of 1.2ml/min. The retention times for 5-FU and Imiquimod were found to be 1.9±0.5 and 6.6±0.5 min respectively. The absorption maxima of 5FU and Imiquimod were found 267nm and 227nm respectively. The method was validated as per ICH guidelines. All the data were found within the specified limits. The limit of detection (LOD) and limit of quantification (LOQ) of 5- Fluorouracil were found to be 0.015μg/mL and 0.048 μg/mL, respectively, and Imiquimod was found to be 0.078μg/mL and 0.237μg/mL, respectively. The method developed in the present study was found to be sensitive, specific, and precise and can be applied for the simultaneous estimation of 5-FU and Imiquimod.


2017 ◽  
Vol 9 (6) ◽  
pp. 34
Author(s):  
Madhavi K. ◽  
Navamani M. ◽  
Prasanthi C.

Objective: To develop a simple, rapid, economic, accurate and precise reverse phase-high performance liquid chromatographic (RP-HPLC) method for the determination of hydrochlorothiazide and candesartan in the pharmaceutical dosage form and to validate as per international conference on harmonization (ICH) guidelines.Methods: The chromatographic separation was performed on Silanol BDS C18 column (250 x 4.6 mm, 5 μm), a mobile phase consisting of water (pH adjusted to 2.8 with orthophosphoric acid): acetonitrile (30:70 % v/v), with a flow rate 1 ml/min and the detection wavelength of 210 nm using photodiode array (PDA) detector.Results: The developed method resulted in elution of hydrochlorothiazide at 2.28 min and candesartan at 4.28 min. The calibration curves were linear (r2=0.999) in the concentration range of 6.25-18.75 μg/ml and 8-24 μg/ml for hydrochlorothiazide and candesartan respectively. The percentage recoveries were found to be 99.78-100.39 for hydrochlorothiazide and 99.87-100.64 for candesartan. The limit of detection (LOD) was found to be 0.410 μg/ml and 0.699 μg/ml for hydrochlorothiazide and candesartan respectively. The limit of quantitation (LOQ) was found to be 1.367 μg/ml and 2.330 μg/ml for hydrochlorothiazide and candesartan respectively.Conclusion: A simple, economic, accurate, precise, linear and rapid RP-HPLC method was developed for simultaneous quantitative estimation of hydrochlorothiazide and candesartan in bulk and pharmaceutical formulation and the method was validated as per ICH guidelines. Hence, the method holds good for the routine analysis of hydrochlorothiazide and candesartan in various pharmaceutical industries as well as in academics.


Author(s):  
M. Murali ◽  
P. Venkateswara Rao

A simple, selective, linear, precise and accurate isocratic RP-HPLC method was developed and validated for rapid assay of Vandetanib, an anticancer drug, in both bulk and tablet dosage form. Elution at a flow rate of 1ml/min was employed on a symmetry C18 column at ambient temperature. The mobile phase consisted of acetonitrile, water and orthophosphoric acid in the ratio of 90:08:02 (v/v/v). Linearity was observed in concentration range of 50-200 ppm. The retention time for Vandetanib was 3.326 min. The method was validated as per the ICH guidelines. The proposed method can be successfully applied for the estimation of Vandetanib in pharmaceutical dosage forms. Moreover the detection alone was also verified through LC-MS of the Vandetanib drug using ESI method which provides future scope for study of this drug using LC-MS method also.


Author(s):  
K Tirumala ◽  
CH.V.S Gautam ◽  
J Gangadhar ◽  
M Jayajeevitha ◽  
Vanitha Prakash K

Reverse phase high performance liquid chromatographic (RP-HPLC) method was developed and validated for the estimation of pitavastatin in tablet dosage form. A Phenomenex Luna C18, 150×4.6 mm i.d, 5 µm particle size with mobile phase consisting of buffer 0.01M potassium dihydrogen ortho phosphate pH (3.75) adjusted with dilute orthophosphoric and acetonitrile in the ratio of 20:80 v/v was used. The flow rate was 1.2 mL/min and eluents were monitored at 248 nm. The retention time was 4.1min. The detector response was linear in the concentration of 25-150 µg/mL, with the regression coefficient of 0.9998. Quantification was done by calculating area of the peak and the limit of detection and limit of quantification were 1.9 µg/mL and 5.7 µg/mL respectively. The percentage assay of pitavastatin was 101.1%. The results of study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate which is useful for the routine determination of pitavastatin in bulk drug and in its pharmaceutical dosage forms.


Sign in / Sign up

Export Citation Format