scholarly journals Clinical outcome in patients with hand lesions associated with complex regional pain syndrome after arthroscopic rotator cuff repair

Author(s):  
Takaki Imai ◽  
Masafumi Gotoh ◽  
Keiji Fukuda ◽  
Misa Ogino ◽  
Hidehiro Nakamura ◽  
...  

Background: Complex regional pain syndrome (CRPS)-related hand lesions are one of the complications following arthroscopic rotator cuff repair (ARCR). This study aimed to investigate the clinical outcomes of patients with CRPS-related hand lesions following ARCR.Methods: Altogether, 103 patients with ARCR were included in this study (mean age, 63.6±8.2 years; 66 males and 37 females; follow-up period, preoperative to 12 months postoperative). Clinical assessment included the Japanese Orthopaedic Association (JOA) score, University of California, Los Angeles (UCLA) score, Constant score, 36-item short form health survey (SF-36) score, and Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) score from preoperative to 12 months postoperatively. The patients were either assigned to the CRPS group or non-CRPS group depending on CRPS diagnosis until the final follow-up, and clinical outcomes were then compared between the groups.Results: Of 103 patients, 20 (19.4%) had CRPS-related hand lesions that developed entirely within 2 months postoperatively. Both groups showed significant improvement in JOA, UCLA, and Constant scores preoperatively to 12 months postoperatively (P<0.0001). Comparisons between the two groups were not significantly different, except for SF-36 “general health perception” (P<0.05) at 12 months postoperatively. At final follow-up, three patients had residual CRPS-related hand lesions with limited range of motion and finger edema.Conclusions: CRPS-related hand lesions developed in 19.4% of patients following ARCR. Shoulder or upper-limb function improved in most cases at 12 months, with satisfactory SF-36 patient-based evaluation results. Patients with residual CRPS-related hand lesions at the last follow-up require long-term follow-up.

2017 ◽  
Vol 45 (6) ◽  
pp. 1283-1288 ◽  
Author(s):  
Philipp R. Heuberer ◽  
Daniel Smolen ◽  
Leo Pauzenberger ◽  
Fabian Plachel ◽  
Sylvia Salem ◽  
...  

Background: The number of arthroscopic rotator cuff surgeries is consistently increasing. Although generally considered successful, the reported number of retears after rotator cuff repair is substantial. Short-term clinical outcomes are reported to be rarely impaired by tendon retears, whereas to our knowledge, there is no study documenting long-term clinical outcomes and tendon integrity after arthroscopic rotator cuff repair. Purpose: To investigate longitudinal long-term repair integrity and clinical outcomes after arthroscopic rotator cuff reconstruction. Study Design: Case series; Level of evidence, 4. Methods: Thirty patients who underwent arthroscopic rotator cuff repair with suture anchors for a full-tendon full-thickness tear of the supraspinatus or a partial-tendon full-thickness tear of the infraspinatus were included. Two and 10 years after initial arthroscopic surgery, tendon integrity was analyzed using magnetic resonance imaging (MRI). The University of California, Los Angeles (UCLA) score and Constant score as well as subjective questions regarding satisfaction with the procedure and return to normal activity were used to evaluate short- and long-term outcomes. Results: At the early MRI follow-up, 42% of patients showed a full-thickness rerupture, while 25% had a partial rerupture, and 33% of tendons remained intact. The 10-year MRI follow-up (129 ± 11 months) showed 50% with a total rerupture, while the other half of the tendons were partially reruptured (25%) or intact (25%). The UCLA and Constant scores significantly improved from preoperatively (UCLA total: 50.6% ± 20.2%; Constant total: 44.7 ± 10.5 points) to 2 years (UCLA total: 91.4% ± 16.0% [ P < .001]; Constant total: 87.8 ± 15.3 points [ P < .001]) and remained significantly higher after 10 years (UCLA total: 89.7% ± 15.9% [ P < .001]; Constant total: 77.5 ± 15.6 points [ P < .001]). The Constant total score and Constant strength subscore, but not the UCLA score, were also significantly better at 10 years postoperatively in patients with intact tendons compared with patients with retorn tendons (Constant total: 89.0 ± 7.8 points vs 75.7 ± 14.1 points, respectively [ P = .034]; Constant strength: 18.0 ± 4.9 points vs 9.2 ± 5.2 points, respectively [ P = .006]). The majority of patients rated their satisfaction with the procedure as “excellent” (83.3%), and 87.5% returned to their normal daily activities. Conclusion: Arthroscopic rotator cuff repair showed good clinical long-term results despite a high rate of retears. Nonetheless, intact tendons provided significantly superior clinical long-term outcomes, making the improvement of tendon healing and repair integrity important goals of future research efforts.


2018 ◽  
Vol 23 (1) ◽  
pp. 70-74 ◽  
Author(s):  
Ryo Tanesue ◽  
Masafumi Gotoh ◽  
Yasuhiro Mitsui ◽  
Hidehiro Nakamura ◽  
Hirokazu Honda ◽  
...  

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Chen Wang ◽  
Pu Yang ◽  
Dongfang Zhang ◽  
In-Ho Jeon ◽  
Tengbo Yu ◽  
...  

Abstract Background Bilateral rotator cuff tears are not uncommon and the timing of the surgical treatment of both shoulders is debated. In the present study, we aimed to compare the clinical outcomes of patients who underwent single-stage or staged bilateral arthroscopic rotator cuff repair. Methods From March 2013 to May 2018, a retrospective review on all patients who underwent bilateral arthroscopic rotator cuff repair at our department was performed. Patients were separated into 2 groups: single-stage and staged. The minimum follow-up period was 2 years. The visual analog scale (VAS), American Shoulder and Elbow Surgeons (ASES) score, University of California, Los Angeles (UCLA) score, Constant-Murley (Constant) score, the range of motion (ROM) of the shoulder and the hospitalization costs were evaluated for comparison between the two groups before and after the operation. Differences between groups were assessed using t-tests and ANOVA. Results All 51 patients completed follow-up of 2 years, single stage (n = 24) and staged group (n = 27). There was no significant difference in the VAS, ASES, UCLA and Constant scores between the single-stage group and the staged group before the operation. Postoperative clinical scores were significantly improved in both groups (P < 0.05). All outcome scores were significantly different between the two groups at 6 months postoperatively, and the staged scored better than the single-stage (P < 0.05). At 12, 18, and 24 months after the operation, the outcome scores were not significantly different between the two groups. At follow-up, the ROM of the shoulder was not significantly different between the two groups. In the single-stage group, the outcome scores and ROM were similar for both shoulders and comparable to the staged group. We also found significant cost savings in the single-stage group (4440.89 ± 130.55 USD) compared to the staged group (5065.73 ± 254.76 USD) (p < 0.05). Conclusions Patients receiving single-stage or staged bilateral arthroscopic rotator cuff repair showed similarly good clinical outcomes at follow-ups longer than 6 months. Moreover, good outcomes were observed on both sides of the single-stage group.


2019 ◽  
Vol 22 (4) ◽  
pp. 203-209
Author(s):  
Sungwook Choi ◽  
Hyunchul Yang ◽  
Hyunseong Kang ◽  
Gyeong Min Kim

Background: Clinical outcomes and prognosis of large and massive rotator cuff tears are known to be unpredictable not only in degeneration of the rotator cuff, but also due to a high rate of retear.Methods: Totally, 81 patients who had undergone arthroscopic rotator cuff repair from May 2008 to February 2016 were evaluated in our study. Clinical and functional evaluations were performed with the Constant score and the University of California, Los Angeles (UCLA) score, as well as full physical examination of the shoulder. All patients were confirmed to have magnetic resonance imaging (MRI) of tendon healing at least 1 year postoperatively.Results: The average age at the time of surgery was 65 years (range, 47?78 years). The average duration of postoperative time in which a follow-up MRI was performed was 36.1 months (range, 12?110 months). Large tears were present in 48 cases (59.3%) and massive tears in 33 cases (40.7%). Overall, there were 33 retear cases (40.7%). All the average clinical outcome scores were significantly improved at the last follow-up (<i>p</i><0.001), although repair integrity was not maintained. Compared to type A, types C, and D of the Collin’s classification showed significantly higher retear rates (<i>p</i>=0.036).Conclusions: Arthroscopic rotator cuff repair yields improved clinical outcomes and a relatively high degree of patient satisfaction, despite the repair integrity not being maintained. Involvement of the subscapularis muscle or infraspinatus muscle had no effect on the retear rate.


2021 ◽  
Vol 49 (2) ◽  
pp. 314-320
Author(s):  
Joo Hyun Park ◽  
Sung-Min Rhee ◽  
Hyong Suk Kim ◽  
Joo Han Oh

Background: Preoperative anxiety and depression are independent predictors of clinical outcomes after arthroscopic rotator cuff repair. However, few studies have evaluated correlations between outcomes such as pain and range of motion (ROM) after arthroscopic rotator cuff repair and preoperative anxiety and depression. Purpose: To evaluate the effects of preoperative anxiety and depression, measured using the Hospital Anxiety and Depression Scale (HADS), on early pain and ROM after rotator cuff repair. Study Design: Cohort study; Level of evidence, 2. Methods: A total of 144 consecutive patients who underwent arthroscopic rotator cuff repair were enrolled and divided into 2 groups according to HADS scores: group A, those with a healthy psychological status (n = 103; anxiety ≤7 and depression ≤7), and group B, those with psychological distress (n = 41; anxiety ≥8 or depression ≥8). Clinical outcomes were assessed using the visual analog scale for pain (pVAS) and ROM at 3 and 6 months postoperatively and annually. Results: There were no significant preoperative differences in age, sex, tear size, pVAS scores, and ROM. However, at 3 months postoperatively, group A showed significantly lower mean pVAS scores (2.2 ± 1.3 vs 3.4 ± 1.8, respectively; P = .001) and significantly higher mean forward flexion (146.4°± 23.0° vs 124.1°± 28.2°, respectively; P < .001) than group B, as well as significantly higher mean levels of internal rotation at the back (T11.5 ± 2.8 vs L1.9 ± 2.5, respectively; P < .001) and significantly higher mean external rotation (42.4°± 15.9° vs 35.2°± 16.8°, respectively; P = .019). At 6 months postoperatively, the mean pVAS score was still significantly lower in group A than in group B (0.8 ± 1.6 vs 1.8 ± 2.1, respectively; P = .016), but other ROM measurements had no significant differences. There was also no significant difference in clinical and functional outcomes at the final follow-up. Conclusion: Anxiety and depression negatively affected clinical outcomes after rotator cuff repair. Recovery from pain and of ROM after arthroscopic rotator cuff repair occurred more quickly in patients with a healthy psychological status. Therefore, assessments of preoperative psychological status should be emphasized to improve early clinical outcomes after arthroscopic rotator cuff repair.


2011 ◽  
Vol 20 (4) ◽  
pp. 518-528 ◽  
Author(s):  
Pietro Randelli ◽  
Paolo Arrigoni ◽  
Vincenza Ragone ◽  
Alberto Aliprandi ◽  
Paolo Cabitza

2017 ◽  
Vol 45 (9) ◽  
pp. 2010-2018 ◽  
Author(s):  
Yong Sang Kim ◽  
Chang Hun Sung ◽  
Sung Hoon Chung ◽  
Sang Joon Kwak ◽  
Yong Gon Koh

Background: The mesenchymal stem cell (MSC)–based tissue engineering approach has been developed to improve the treatment of rotator cuff tears. Hypothesis/Purpose: The purpose was to determine the effect of an injection of adipose-derived MSCs loaded in fibrin glue during arthroscopic rotator cuff repair on clinical outcomes and to evaluate its effect on structural integrity using magnetic resonance imaging (MRI). The hypothesis was that the application of adipose-derived MSCs would improve outcomes after the surgical repair of a rotator cuff tear. Study Design: Cohort study; Level of evidence, 3. Methods: Among 182 patients treated with arthroscopic surgery for a rotator cuff tear, 35 patients treated with arthroscopic rotator cuff repair alone (conventional group) were matched with 35 patients who underwent arthroscopic rotator cuff repair with an injection of adipose-derived MSCs loaded in fibrin glue (injection group) based on sex, age, and lesion size. Outcomes were assessed with respect to the visual analog scale (VAS) for pain, range of motion (ROM) (including forward flexion, external rotation at the side, and internal rotation at the back), and functional measures of the Constant score and University of California, Los Angeles (UCLA) shoulder rating scale. Repaired tendon structural integrity was assessed by using MRI at a minimum of 12 months after surgery, and the mean clinical follow-up was 28.8 ± 4.2 months in the conventional group and 28.3 ± 3.8 months in the injection group. Results: The mean VAS score at rest and during motion improved significantly in both groups after surgery. However, there were no significant differences between the groups at the final follow-up ( P = .256 and .776, respectively). Compared with preoperative measurements, forward flexion and external rotation at the side significantly improved at the final follow-up in both groups (all P < .05). However, no significant improvements in internal rotation at the back were observed in either group ( P = .625 and .834 for the conventional and injection groups, respectively). There were also no significant differences between the groups at the final follow-up for any of the 3 ROM positions (all P > .05). The mean Constant score and UCLA score improved significantly in both groups after surgery, but there were no significant differences between the groups at the final follow-up ( P = .634 and .302, respectively). MRI indicated a retear rate of 28.5% in the conventional group and 14.3% in the injection group ( P < .001). Conclusion: This study revealed that an injection of adipose-derived MSCs loaded in fibrin glue during rotator cuff repair could significantly improve structural outcomes in terms of the retear rate. There were, however, no clinical differences in the 28-month period of follow-up. Although still in the early stages of application, MSC augmentation of surgical rotator cuff repair appears useful for providing an adequate biological environment around the repair site.


Sign in / Sign up

Export Citation Format

Share Document