scholarly journals Unruptured aneurysm producing thunderclap headache treated with endovascular coil embolization

Author(s):  
Pınar Gelener
2021 ◽  
Vol 10 (2) ◽  
pp. 326
Author(s):  
Grégory Secco ◽  
Olivier Chevallier ◽  
Nicolas Falvo ◽  
Kévin Guillen ◽  
Pierre-Olivier Comby ◽  
...  

The endovascular treatment of renal artery aneurysms (RAAs) has lower morbidity and shorter stay lengths compared to surgical repair. Here, we describe coil packing with or without remodeling and assess outcomes and complications. We retrospectively identified the 19 consecutive preventive endovascular RAA coil embolizations done in 18 patients at our center in 2010–2020. Patient and aneurysm characteristics, technical success rate, complications, and recurrences were recorded. Mean patient age was 63 ± 13 years. The RAA was >1.5 cm in 11 cases, and in four cases, the aneurysm-to-parent artery size ratio was >2. Simple coiling was performed for 11 (57.9%) aneurysms, stent-assisted coiling for seven (36.8%) aneurysms, and balloon-assisted coiling for one (5.3%) aneurysm. Technical success rate was 100%. Complete definitive RAA exclusion was achieved with a single procedure for 17 (89.5%) aneurysms, whereas two (10.5%) aneurysms required a repeat procedure. Four minor complications occurred but resolved with no long-term consequences. No major complications occurred during the mean follow-up of 41.1 ± 29.7 months. Coil embolization by sac packing or remodeling proved very safe and effective. Together with the known lower morbidity and shorter stay length compared to open surgery, these data indicate that this endovascular procedure should become the preventive treatment of choice for RAAs.


2012 ◽  
Vol 18 (3) ◽  
pp. 326-332 ◽  
Author(s):  
P. Gölitz ◽  
T. Struffert ◽  
M. Arc Saake ◽  
F. Knossalla ◽  
A. Doerfler

This investigation aimed to demonstrate the potential of intraprocedural angiographic CT in monitoring complex endovascular coil embolization of direct carotid cavernous fistulas. Angiographic CT was performed as a dual rotational 5 s run with intraarterial contrast medium injection in two patients during endovascular coil embolization of direct carotid cavernous fistulas. Intraprocedural angiographic CT was considered helpful if conventional 2D series were not conclusive concerning coil position or if a precise delineation of the parent artery was impossible due to a complex anatomy or overlying coil material. During postprocessing multiplanar reformatted and dual volume images of angiographic CT were reconstructed. Angiographic CT turned out to be superior in the intraprocedural visualization of accidental coil migration into the parent artery where conventional 2D-DSA series failed to reliably detect coil protrusion. The delineation of coil protrusion by angiographic CT allowed immediate correct coil repositioning to prevent parent artery compromising. Angiographic CT can function as a valuable intraprocedurally feasible tool during complex coil embolizations of direct carotid cavernous fistulas. It allows the precise visualization of the cerebral vasculature and any accidental coil protrusion can be determined accurately in cases where conventional 2D-DSA series are unclear or compromised. Thus angiographic CT might contribute substantially to reduce procedural complications and to increase safety in the management of endovascular treatment of direct carotid cavernous fistulas.


Neurosurgery ◽  
2006 ◽  
Vol 59 (1) ◽  
pp. 43-52 ◽  
Author(s):  
John K. Birknes ◽  
Sung-Kyun Hwang ◽  
Aditya S. Pandey ◽  
Kevin Cockroft ◽  
Anne-Marie Dyer ◽  
...  

2020 ◽  
Vol 19 (6) ◽  
pp. E597-E598
Author(s):  
Maureen A Darwal ◽  
Zakaria Hakma ◽  
Mandy J Binning ◽  
Adam Arthur ◽  
Bain Mark ◽  
...  

Abstract Since the International Subarachnoid Aneurysm Trial,1 endovascular treatment has been the favored treatment for appropriate ruptured intracranial aneurysms. While our endovascular technology has advanced to allow us to treat the majority of intracranial aneurysms, simple coil embolization is still the most common modality. This video demonstrates the fundamentals of aneurysm catheterization and coiling for safe treatment. In addition, the set-up and devices are detailed. This video is to add to the library of basic techniques that will aid a large number of practitioners. This patient consented to endovascular treatment. The video demonstrates endovascular coil embolization of a posterior communicating artery aneurysm in a 76-yr-old female who presented with a subarachnoid hemorrhage. Image of biplane suite in video used courtesy of Siemens Medical Solutions USA, Inc. Illustration at 5:12 reprinted from Yasargil MG, et al, Microneurosurgery IV B, p. 9, Thieme, New York, 1995.


2020 ◽  
pp. 1-9
Author(s):  
Alejandro Tomasello ◽  
David Hernandez ◽  
Laura Ludovica Gramegna ◽  
Sonia Aixut ◽  
Roger Barranco Pons ◽  
...  

OBJECTIVEThe goal of this study was to evaluate the effectiveness and safety of a new noncompletely occlusive net-assisted remodeling technique in which the Cascade net device is used for temporary bridging of intracranial aneurysms.METHODSBetween July 2018 and May 2019, patients underwent coil embolization with the Cascade net device within 4 centers in Europe. Analysis of angiographic (modified Raymond-Roy classification [MRRC]) and clinical outcomes data was conducted immediately following treatment and at the 6-month follow-up.RESULTSFifteen patients were included in the study (mean age 58 ± 13 years, 11/15 [73.3%] female). Ten patients had unruptured aneurysms, and 5 presented with ruptured aneurysms with acute subarachnoid hemorrhage. The mean aneurysm dome length was 6.27 ± 2.33 mm and the mean neck width was 3.64 ± 1.19 mm. Immediately postprocedure, MRRC type I (complete obliteration) was achieved in 11 patients (73.3%), whereas a type II (residual neck) was achieved in 4 patients (26.7%). Follow-up examination was performed in 7/15 patients and showed stabilization of aneurysm closure with no thromboembolic complications and only 1 patient with an increased MRRC score (from I to II) due to coil compression.CONCLUSIONSInitial experience shows that the use of a new noncompletely occlusive net-assisted remodeling technique with the Cascade net device may be safe and effective for endovascular coil embolization of intracranial aneurysms.


2011 ◽  
Vol 8 (4) ◽  
pp. 346-352 ◽  
Author(s):  
Michael J. Ellis ◽  
Samuel Cheshier ◽  
Sunjay Sharma ◽  
Derek Armstrong ◽  
Cynthia Hawkins ◽  
...  

Among the neoplastic conditions that affect patients with neurofibromatosis Type 1 (NF1) are malignant peripheral nerve sheath tumors (MPNSTs), which typically arise from peripheral nerves of the limbs, trunk, and lumbar and brachial plexuses. Ionizing radiation is an established risk factor for MPNST development, especially in susceptible patients such as those with NF1. Patients with NF1 are also at risk for intracranial aneurysms, which are increasingly being successfully managed with endovascular therapies. The authors describe the case of a 9-year-old, previously healthy girl who presented in extremis with a right frontal intracerebral hemorrhage resulting from a ruptured right middle cerebral artery (MCA) trifurcation aneurysm. Following urgent decompressive craniectomy, the patient underwent endovascular coil embolization of the MCA aneurysm without complication. Given her mother's history of NF1, the child underwent genetic testing, which disclosed signs positive for NF1. The patient recovered well, but follow-up MR imaging and MR angiography performed at 14 months demonstrated a large frontotemporal mass encasing the right MCA trifurcation. The patient underwent frontotemporal craniotomy and subtotal resection of the mass, which was histologically found to be an intracranial MPNST. The patient received chemotherapy and focal radiation therapy and remains alive at 6 months postresection. To the authors' knowledge, this represents the only known case of intracranial neoplasm arising in the region of an intracranial aneurysm repaired by endovascular coil embolization. While patients with NF1 represent a population with genetic susceptibility to radiation-induced tumors, the pathogenesis of intracerebral MPNSTs remains poorly understood.


2019 ◽  
Vol 25 (6) ◽  
pp. 681-684 ◽  
Author(s):  
Tomotaka Ohshima ◽  
Shigeru Miyachi ◽  
Naoki Matsuo ◽  
Reo Kawaguchi ◽  
Ryuya Maejima ◽  
...  

Complete and secure occlusion of the entire aneurysmal neck remains a problem despite major advances in the treatment of intracranial aneurysms using endovascular coil embolization. Here, we present our initial clinical experience using a novel strategy for endovascular coil embolization involving a microcatheter tip, known as the “Γ (gamma) tip method,” and compare the in vitro results of this technique with those of conventional straight microcatheters. The microcatheters were bent at a right angle starting 1–2 mm from the length of the tip using a catheter-shaping mandrel and a hot air gun. The tiny right-angled tip is the “Γ tip.” In aneurysm models, we assessed the efficacy of shaping during coil deployment. The Γ-tipped microcatheters demonstrated better movement and oscillation during insertion of the coil into the aneurysm compared with the straight-tipped catheters. Moreover, the Γ-tipped microcatheter provided less coil protrusion into the parent artery and less microcatheter kickback compared with the straight tip. With the Γ-tipped microcatheter, even if the first coil loop migrated into the parent artery, its subsequent dynamic movement routed it back into the aneurysm. The Γ tip method enabled smooth movement of the microcatheter into the aneurysm, demonstrating the safety and security of coil insertion using the Γ tip compared with the conventional straight tip.


Sign in / Sign up

Export Citation Format

Share Document