Influence of guide vane shape on the performance and internal flow of a cross flow wind turbine

2013 ◽  
Vol 37 (2) ◽  
pp. 163-169
Author(s):  
Sung-Woo Son ◽  
Patrick Mark Singh ◽  
Young-Do Choi
Author(s):  
Kazuki Takeuchi ◽  
Junichiro Fukutomi ◽  
Hidetoshi Kodani ◽  
Hironori Horiguchi

The wind turbine has become more popular in recent years, but on the other hand, the developments of small wind-turbine have been legging behind. Because, the energy density of wind is small, since the efficiency of the main part of a wind turbine is very low. The construction costs become comparatively high-priced. Then, the main part of this subject is to show that, by collecting and sucking out more winds, a wind turbine is made to pass many winds and the new cross-flow wind turbine that increases an output coefficient is proposed. The cross-flow wind turbine has high torque and low speed characteristics and the structure are very simple. So, it can be used in a large wind velocity region. However, even if the power coefficient is high, it is about 10%. The purpose of this paper is to show how we can improve the power coefficient by applying a casing, which has a nozzle and a diffuser. This research was made to clear up fundamental characteristics of the interaction between outer flow and inner flow. Three kinds of cross-flow wind turbines were designed. The nozzle and diffuser have been designed suitable for the performance of wind turbine. The flow simulations by CFD have been carried out for various types of casings at 20 m/s with Fluent Ver5.0. All Wind tunnel experiments were performed at 20m/s. The case of casing 2, which have plate arranged near the separation point of cylinder, also experimented. The rotor that is settled in the casing 1 shows a larger power coefficient than the case without a casing. The casing of the cross-flow turbine makes a pressure difference between inflow and outflow. The pressure difference increases the mass flow rate. Therefore much more wind passes through into the cross-flow turbine. In this experiment, the power coefficient increased 1.5 times in the case with casing. A still higher output coefficient could be obtained in the case where it is shown by the casing 2.


2005 ◽  
Vol 2005 (0) ◽  
pp. 270
Author(s):  
Ken-ichi KANEKO ◽  
Satoshi KAGAWA ◽  
Yoshiharu TSUJIKAWA
Keyword(s):  

2000 ◽  
Vol 2000 (0) ◽  
pp. 263
Author(s):  
Aya YAMADA ◽  
Koki KISHINAMI ◽  
Kouji KOBAYASHI ◽  
Jun SUZUKI ◽  
Norihei KON ◽  
...  

2018 ◽  
Vol 159 ◽  
pp. 02014 ◽  
Author(s):  
Budi Santoso ◽  
Dominicus Danardono Dwi Prija Tjahjana

The purpose of this experiment is to know the influence of a single guide vane position and angle to the performance of a cross-flow wind turbine. The cross-flow wind turbine was positioned at the discharge outlet of a cooling tower model to harness the discharged wind for electricity generation. A guide vane was used to enhance the rotational speed of the turbines for power augmentation. Various position and angle of attack of the guide vane were tested in this experiment. To avoid negative impact on the performance of the cooling tower fan and to optimize the wind turbine performance, the turbine position on the discharge wind stream was also studied. The result showed that cross-flow wind turbine with a guide vane attached at the right position had a higher coefficient of power than cross flow turbine without guide vane. A crossflow wind turbine with the guide vane at the position of 150 mm from the center and 30° angles had the highest coefficient of power of 0.49. Comparing to the wind turbine without guide vane, the coefficient of power of the cross-flow wind turbine was increased about 84.3%.


2001 ◽  
Vol 2001.11 (0) ◽  
pp. 464-467
Author(s):  
Aya YAMADA ◽  
Koki KISHINAMI ◽  
Kouji KOBAYASHI ◽  
Jun SUZUKI ◽  
Norihei KON ◽  
...  

Author(s):  
Junichiro Fukutomi ◽  
Toru Shigemitsu ◽  
Masaaki Toyohara

A cross-flow wind turbine has a high torque coefficient at a low tip speed ratio. Therefore, it is a good candidate for use as a self-starting turbine. Furthermore, it has low noise and excellent stability; therefore, it has attracted attention from the viewpoint of applications as a small wind turbine for an urban district. However, its maximum power coefficient is extremely low (10%) as compared to that of other small wind turbines. In order to improve the performance and the flow condition of the cross-flow rotor, symmetrical casing with a nozzle and a diffuser are proposed and experimental research with the symmetrical casing is conducted. The maximum power coefficient is obtained as Cpmax = 0.17 for casing and Cpmax = 0.098 in the case without the casing. In the present study, power characteristics of the cross-flow rotor and those of the symmetrical casing with the nozzle and the diffuser are investigated. Then, the performance and internal flow patterns of the cross-flow wind turbine with the symmetrical casings are clarified. After that, the effect of the side boards set on the symmetrical casing is discussed on the basis of the analysis results.


Processes ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. 266
Author(s):  
Md Rakibuzzaman ◽  
Sang-Ho Suh ◽  
Hyoung-Ho Kim ◽  
Youngtae Ryu ◽  
Kyung Yup Kim

Discharge water from fish farms is a clean, renewable, and abundant energy source that has been used to obtain renewable energy via small hydropower plants. Small hydropower plants may be installed at offshore fish farms where suitable water is obtained throughout the year. It is necessary to meet the challenges of developing small hydropower systems, including sustainability and turbine efficiency. The main objective of this study was to investigate the possibility of constructing a small hydropower plant and develop 100 kW class propeller-type turbines in a fish farm with a permanent magnet synchronous generator (PMSG). The turbine was optimized using a computer simulation, and an experiment was conducted to obtain performance data. Simulation results were then validated with experimental results. Results revealed that streamlining the designed shape of the guide vane reduced the flow separation and improved the efficiency of the turbine. Optimizing the shape of the runner vane decreased the flow rate, reducing the water power and increasing the efficiency by about 5.57%. Also, results revealed that tubular or cross-flow turbines could be suitable for use in fish farm power plants, and the generator used should be waterproofed to avoid exposure to seawater.


Sign in / Sign up

Export Citation Format

Share Document