scholarly journals Left Atrial Appendage Transcatheter Occlusion with AMPLATZERT AmuletT Device: Real Life Data with Mid-Term Follow-Up Results

Author(s):  
Mehmet Levent Sahiner ◽  
Ergun Baris Kaya ◽  
Cem Çöteli ◽  
Kudret Aytemir
2006 ◽  
Vol 186 (2) ◽  
pp. 361-364 ◽  
Author(s):  
Oliver K. Mohrs ◽  
Rainer Schraeder ◽  
Steffen E. Petersen ◽  
Detlef Scherer ◽  
Bernd Nowak ◽  
...  

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
A Briosa E Gala ◽  
MTB Pope ◽  
C Monteiro ◽  
M Leo ◽  
TR Betts

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Left atrial appendage occlusion (LAAO) is a well-established stroke prevention strategy in patients with non-valvular atrial fibrillation (AF) and high risk of bleeding or contra-indication to oral anticoagulation (OAC). Despite encouraging randomised control trial and international registry safety and efficacy data, long-term outcome data remains sparce. Purpose This study sought to evaluate the long-term outcomes in ‘real-world’ AF patients undergoing left atrial appendage occlusion in a large UK tertiary centre. Methods This retrospective study included all patients that had a LAAO device implanted in our institution from January 2010 to December 2020. Medical notes, electronic patient records, procedural and imaging reports were reviewed. Annual bleeding risk was extrapolated from the Swedish National Cohort study according to CHA2DS2-VASc and HASBLED score. Results During the study period a total of 225 patients underwent LAAO device implant. Seventy-two percent were male, age 74 ± 8 years, BMI 27 ± 6 kg/m2, CHA2DS2-VASc score 4.4 ± 1.2, HASBLED score 3.2 ± 0.8 and at high risk of stroke (98 ischaemic strokes and 129 haemorrhagic strokes) and bleeding (151 life-threatening bleeding episodes). Three different LAAO devices were used: 136 Watchman, 54 Watchman FLX and 35 Amplatzer Cardiac plugs. Three patients (1.3%) had fatal complications related to the procedure. At discharge, 10% were taking single antiplatelet (ATP), 79% dual-antiplatelet (DAPT), 1.4% OAC, 3.6% ATP and OAC, 3.1% DAPT and OAC, 1.3% were not taking any anti-thrombotic. Nine (4%) patients had device-related thrombus on follow-up transoesophageal echocardiography with no significant difference between devices (5.0%, 2.8% and 6.7% p = 0.8, respectively) and anticoagulation strategy (p = 0.7). Over a total follow-up of 889 patient-years (mean follow-up 3.9 ± 3.7 years), 24 (10.4%) patients died, 55 patients (6.2/100 patient-years) suffered an adverse event, 15 ischaemic strokes (1.7/100 patient-years) and 20 non-procedural major bleeding episodes (2.3/100 patient-years) occurred. Compared to estimated annual stroke and bleeding risk adjusted for CHA2DS2-VASc and HASBLED score, our cohort had a 79% and 65% relative risk reduction in ischaemic stroke and major bleeding, respectively. Conclusion In this cohort of "real-world" high-risk patients, major bleeding and thromboembolic rate remained low on long-term follow-up. Abstract Figure 1


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Rakesh Gopinathannair ◽  
Scott M Koerber ◽  
Krishna Akella ◽  
Dhanunjaya Lakkireddy

Background: The Amulet IDE trial is an ongoing, randomized, worldwide trial, enrolled but following patients with non-valvular atrial fibrillation (AF) at high risk of stroke. The study is comparing the safety and effectiveness of the Amplatzer™ Amulet™ left atrial appendage (LAA) Occluder to the Watchman device. At US sites, the implanting physicians only had experience with the Watchman device; therefore, up to three roll-in subjects with Amplatzer Amulet device implantation were permitted prior to randomization. The purpose of this analysis is to describe the peri-procedural outcomes for the roll-in cohort. Methods: Roll-in subjects met the same eligibility criteria and have the same data collection requirements as randomized subjects. Adverse events were adjudicated by an independent clinical events committee and LAA occlusion was assessed by an independent core laboratory based on the 45-day TEE. Major adverse events included all cause death, ischemic stroke, systemic embolism or device-/procedure-related events requiring open cardiac surgery or major endovascular intervention within 7 days post implant or hospital discharge, whichever is later. Results: From August 2016 to November 2018, 201 patients with non-valvular AF at high risk of stroke and bleeding were enrolled at 82 sites as roll-in subjects. Mean age was 74.2 ± 7.5 years and 62% of subjects were male. The Amplatzer Amulet device was successfully deployed in 99% of subjects. Major adverse events within 7 days or hospital discharge occurred in 2.5% of patients and included death (n=3), ischemic stroke (n=1) and vascular access site bleeding (n=1). The majority (79%) of patients were discharged on antiplatelet therapy only or no anti-thrombotic medication. TEE follow-up at the 45-day visit revealed adequate (≤ 5 mm jet) occlusion of the appendage in 98.9% (178/180) of patients. Device-related thrombus (DRT) was identified by the core laboratory in 6 patients (3%); no patient experienced a thrombo-embolic event. Conclusions: In the roll-in cohort, with implanting physicians having no prior experience using the Amplatzer™ Amulet™ device, there was a low rate of procedural complications and high rates of both implant success and adequate LAA sealing at follow up.


Sign in / Sign up

Export Citation Format

Share Document