scholarly journals Long-term effect of anticoagulation following left atrial appendage occlusion with the LARIAT device in patients with nonvalvular atrial fibrillation: impact on thromboembolism, bleeding and mortality. Real life data

2020 ◽  
Vol 16 (1) ◽  
pp. 89-96
Author(s):  
Radosław Litwinowicz ◽  
Grzegorz Filip ◽  
Dorota Sobczyk ◽  
Dhanunjaya Lakkireddy ◽  
Venkat Vuddanda ◽  
...  
2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Jia Yu ◽  
Yufeng Liu ◽  
Peng Sun ◽  
Xing Guo ◽  
Haiyang Jiang ◽  
...  

Background and Objective. Thrombolytics and anticoagulants are conventional drugs for ischemic stroke (IS) treatment, whereas some patients have unfavorable responses to these drugs. The disease presents a relatively high recurrence rate. This investigation attempted to unveil the long-term effect of left atrial appendage occlusion (LAAO) in treating patients with previous IS on the disease recurrence. Methods. A total of 120 patients with IS admitted to Tangdu Hospital from July 2016 to September 2017 were grouped into the control group ( n = 60 ) and the observation group ( n = 60 ). Patients in the control group were only treated with thrombolytics and anticoagulants while those in the observation group were treated with both drugs and LAAO. Transesophageal echocardiography (TEE) was performed to observe the occlusion of LAA in patients in the observation group after 45 d and 6 months, respectively. Clinical outcomes in two groups were compared from the following aspects: recurrence of IS, incidence of systemic embolism, and the 3-year recurrence-free survival (RFS). The 3-year IS recurrence of patients was compared by Fisher’s exact test. Results. No significant differences were observed at baseline levels (age, sex, etc.) between the observation group and control group ( p > 0.05 ). During follow-up visit of 45 d and 6 months, all occluders met the efficacious occludsion criteria. The results of TEE at 45 d after LAAO showed that 50% of patients (30/60) in the observation group had complete occlusion of LAA. The results of TEE at 6 months after LAAO suggested that 58.3% of patients (35/60) had complete occlusion of LAA. IS recurrence in the observation group (3.33%, 2/60) was significantly lower than that in the control group (18.33%, 11/60), with the difference presenting statistical significance ( p = 0.008 ). Incidence of systemic embolism in the observation group (1.67%, 1/60) was markedly lower than that in the control group (13.33%, 11/60) ( p = 0.014 ). The average RFS in the observation group (31.97 months, 95% CI: 27.50~32.31 months) was notably longer than that in the control group (29.91 months, 95% CI: 29.85~32.92 months) ( p < 0.05 ). The 3-year IS recurrence of patients between two groups compared by Fisher’s exact test showed significant differences (1 year: p = 0.014 , 2 year: p = 0.008 , 3 year: p = 0.008 ). Conclusion. Regarding patients with previous IS who had poor response to thrombolytics and anticoagulants, LAAO could effectively decrease recurrence of IS and incidence of systemic embolism and prolong RFS of patients. LAAO was, therefore, an alternative for patients with high IS recurrence risk.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
A Briosa E Gala ◽  
MTB Pope ◽  
C Monteiro ◽  
M Leo ◽  
TR Betts

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Left atrial appendage occlusion (LAAO) is a well-established stroke prevention strategy in patients with non-valvular atrial fibrillation (AF) and high risk of bleeding or contra-indication to oral anticoagulation (OAC). Despite encouraging randomised control trial and international registry safety and efficacy data, long-term outcome data remains sparce. Purpose This study sought to evaluate the long-term outcomes in ‘real-world’ AF patients undergoing left atrial appendage occlusion in a large UK tertiary centre. Methods This retrospective study included all patients that had a LAAO device implanted in our institution from January 2010 to December 2020. Medical notes, electronic patient records, procedural and imaging reports were reviewed. Annual bleeding risk was extrapolated from the Swedish National Cohort study according to CHA2DS2-VASc and HASBLED score. Results During the study period a total of 225 patients underwent LAAO device implant. Seventy-two percent were male, age 74 ± 8 years, BMI 27 ± 6 kg/m2, CHA2DS2-VASc score 4.4 ± 1.2, HASBLED score 3.2 ± 0.8 and at high risk of stroke (98 ischaemic strokes and 129 haemorrhagic strokes) and bleeding (151 life-threatening bleeding episodes). Three different LAAO devices were used: 136 Watchman, 54 Watchman FLX and 35 Amplatzer Cardiac plugs. Three patients (1.3%) had fatal complications related to the procedure. At discharge, 10% were taking single antiplatelet (ATP), 79% dual-antiplatelet (DAPT), 1.4% OAC, 3.6% ATP and OAC, 3.1% DAPT and OAC, 1.3% were not taking any anti-thrombotic. Nine (4%) patients had device-related thrombus on follow-up transoesophageal echocardiography with no significant difference between devices (5.0%, 2.8% and 6.7% p = 0.8, respectively) and anticoagulation strategy (p = 0.7). Over a total follow-up of 889 patient-years (mean follow-up 3.9 ± 3.7 years), 24 (10.4%) patients died, 55 patients (6.2/100 patient-years) suffered an adverse event, 15 ischaemic strokes (1.7/100 patient-years) and 20 non-procedural major bleeding episodes (2.3/100 patient-years) occurred. Compared to estimated annual stroke and bleeding risk adjusted for CHA2DS2-VASc and HASBLED score, our cohort had a 79% and 65% relative risk reduction in ischaemic stroke and major bleeding, respectively. Conclusion In this cohort of "real-world" high-risk patients, major bleeding and thromboembolic rate remained low on long-term follow-up. Abstract Figure 1


Sign in / Sign up

Export Citation Format

Share Document