Development and Validation for Simultaneous Estimation of Gabapentin, Mecobalamin and Alpha Lipoic Acid in Tablet Formulation

2020 ◽  
Vol 12 (1) ◽  
pp. 74
Author(s):  
Dilip Chandak ◽  
Pushpendra Sharma
2016 ◽  
Vol 9 (5) ◽  
pp. 513
Author(s):  
Vitthal S. Hiwale ◽  
Sagar M. Bhangale ◽  
Sachin S. Rane ◽  
Milind E. Chaudhari ◽  
Rajesh Y. Chaudhari ◽  
...  

Author(s):  
AWDHUT PIMPALE ◽  
RAJENDRA KAKDE

Objective: The present work was focused on the development and validation of reversed-phase high-performance liquid chromatography (RP-HPLC) method which is simple, rapid, precise, accurate, sensitive, economical, and stability-indicating for the quantification of rosuvastatin (RSV) calcium and clopidogrel bisulfate (CLO) in bulk and tablet formulation. Methods: The separation was attained on RP Princeton (C18) column with dimensions (250 mm × 4.6 mm, 5 μ) employing buffer which is a mixture of water (pH 3.0, adjusted with orthophosphoric acid), and methanol in the ratio (20:80) v/v as mobile phase, at flow rate 1.0 ml/min and detection was carried out at wavelength 240 nm. The retention time under the optimized condition of RSV calcium and CLO was found to be 2.844 min and 4.388 min, respectively. Results: The linearity of the method was demonstrated in the concentration range of 6–16 µg/ml and 45–120 µg/ml for RSV calcium and CLO with a correlation coefficient (r2) of 0.9999 and 0.9996, respectively. The percentage relative standard deviation was ˂2% and percentage recovery was found to be 100.12–101.37% and 99.72–101.09% for RSV calcium and CLO, respectively. Assay of marketed tablet formulation was found to be 98.99% and 99.92%, respectively. Conclusion: The developed RP-HPLC method was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical and could be used for regular quality control of RSV calcium and CLO in bulk and tablet formulations.


INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (04) ◽  
pp. 45-51
Author(s):  
N. C. Patel ◽  
A. P. Patel ◽  
J. K. Patel

A chemometric method, Partial Least Square, was applied for the simultaneous estimation of epigallocatechin gallate and curcumin in tablet formulation. Twenty five mixed sample solutions were prepared for chemometric calibration as training set and sixteen mixed solution for validation set using Full Factorial Design. The absorbance data matrix was obtained by measuring absorbance at 20 different wavelengths in the range of 220 to 410 nm (Δλ = 10 nm). The developed calibration data was used to test tablet formulation containing epigallocatechin gallate and curcumin. The developed methods were validated using RMSECV and RMSEP. The chemometric calculations were performed using Minitab 16.1.1 and Microsoft Excel 2010. The method is also more accurate and precise than conventional UV methods.


Sign in / Sign up

Export Citation Format

Share Document