scholarly journals Comparison of Circumference Body Composition Measurements and Eight-Point Bioelectrical Impedance Analysis to Dual Energy X-Ray Absorptiometry to Measure Body Fat Percentage

2017 ◽  
Vol 182 (7) ◽  
pp. e1908-e1912 ◽  
Author(s):  
Travis M. Combest ◽  
Robin S. Howard ◽  
Anne M. Andrews
2017 ◽  
Vol 30 (1) ◽  
pp. e23071 ◽  
Author(s):  
Robinson Ramírez-Vélez ◽  
Alejandra Tordecilla-Sanders ◽  
Jorge Enrique Correa-Bautista ◽  
Katherine González-Ruíz ◽  
Emilio González-Jiménez ◽  
...  

Author(s):  
Melissa M. Montgomery ◽  
Risto H. Marttinen ◽  
Andrew J. Galpin

Background: Accurate and accessible methods of body composition are necessary to ensure health and safety of wrestlers during competition. The most valid and reliable instruments are expensive and relatively inaccessible to high school wrestlers; therefore, more practical technology is needed. Objective: To compare body fat percentage (BF%) results from 4 bioelectrical impedance analysis (BIA) devices to those from air displacement plethysmography (ADP) in adolescent wrestlers. Methodology: 134 adolescent male and female wrestlers (1.72±0.9 m, 66.8±14.3 kg, 15.6±1.1 yrs.) were tested for hydration and then completed 4 body composition tests with different BIA devices and one with Bod Pod. Relative and absolute agreement were assessed between each BIA device and ADP on a single day. Results: When compared with ADP, all devices demonstrated excellent reliability (ICC (2,1)) range: 0.88-0.94), but questionable measurement error (SEM range: 2.3-3.6 %BF). Bland-Altman plots revealed that each bioelectrical impedance device we tested over-estimated body fat percent in high school wrestlers (range: 0.8-3.6 %BF) and demonstrated wide 95% limits of agreement (range: 15.0-20.8 %BF) compared to ADP. Conclusions: The devices investigated demonstrated reasonable measurement accuracy. However, wide margins of error of each device were noted. Caution should be taken when assessing adolescent wrestlers with lower amounts of body fat, as it may result in failing to identify those who do not meet the minimum body fat percentage for competition. The governing bodies should use the research data in the decision-making process regarding appropriate devices for use in their weight management programs. 


2021 ◽  
pp. 30-34
Author(s):  
O. A. Nikitinskaya ◽  
N. V. Toroptsova

Obesity is a risk factor for many chronic diseases. Several research methods are used to determine the amount of body fat, including the «gold standard» dual-energy X-ray absorptiometry (DXA). The bioelectrical impedance analysis (BIA) method is an alternative for assessing body composition that does not require special conditions for placement and examination, but the accuracy of its results depends on the hydration of the body.Objective. To compare the results of determining the percentage of body fat using multi-frequency (MF) BIA and DXA.Material and methods. The study included 20 volunteers (11 women and 9 men) aged 26 to 70 years without serious metabolic, cardiovascular or endocrine diseases. Two repeated measurements were performed using the MF-BIA method on the MS FIT device and the DXA method on the Lunar Prodigy Advance device.Results. There were no significant differences in the average percentage of body fat in repeated measurements by MF-BIA and DXA methods, and the intra-group correlation coefficients (r2 ) were 0.999 and 0.997, respectively. A high and significant correlation in percentage of body fat was found between the MF-BIA and DXA (r = 0.973, p < 0.001). The average difference between the results of these two methods was 0.1243%. Differences in percentage of body fat that exceeded two or more standard deviations were detected less than in 5% cases, so the data on body fat content estimated using DXA and BIA are consistent and can be considered almost equal.Conclusion. Our study has shown that the MS FIT body composition device using the MF-BIA method can be an alternative to DXA for assessing the percentage of body fat without introducing additional formulas to recalculate the data obtained.


2018 ◽  
Author(s):  
Carla M Prado ◽  
Camila LP Oliveira ◽  
M Cristina Gonzalez ◽  
Steven B Heymsfield

Body composition assessment is an important tool in both clinical and research settings able to characterize the nutritional status of individuals in various physiologic and pathologic conditions. Health care professionals can use the information acquired by body composition analysis for the prevention and treatment of diseases, ultimately improving health status. Here we describe commonly used techniques to assess body composition in healthy individuals, including dual-energy x-ray absorptiometry, bioelectrical impedance analysis, air displacement plethysmography, and ultrasonography. Understanding the key underlying concept(s) of each assessment method, as well as its advantages and limitations, facilitates selection of the method of choice and the method of the compartment of interest. This review contains 5 figures, 3 tables and 52 references Key words: air displacement plethysmography, bioelectrical impedance analysis, body composition, disease, dual-energy x-ray absorptiometry, health, muscle mass, nutritional status, obesity, sarcopenia, ultrasound fat mass


Sign in / Sign up

Export Citation Format

Share Document