The Eustachian valve (EV) is located in the orifice of inferior vena cava and belongs to structures of the normal heart. It plays an important role in the fetal blood flow by directing the flow of blood from inferior vena cava through an open foramen ovale to the left atrium, thereby ensuring the systemic flow in a fetus and bypassing the pulmonary circulation. After birth and upon closure of the foramen ovale, the valve ceases to function and tends to regress. Usually, a prominent EV is a clinically non-significant ultrasound finding. In isolated cases, however, it can cause significant hemodynamic abnormalities and subsequent rhythm disorders, delayed fetal development and transient hypoxemia in newborns. It can extremely rare be a cause of blood right-toleft shunting through the foramen ovale leading to desaturation. Clinically it can manifest by central cyanosis in newborns and infants. The differential diagnosis is made in neonatal intensive care units. We present a  case of transient arterial hypoxemia in a  newborn with prominent EV and inter-atrial shunt. A  one-month old infant was transferred from the Department of Pediatric Cardiology with a  history of transient hypoxemic spells related to right-to-left shunting via atrial septal defect caused by obstruction of the tricuspid valve by the prominent EV. The instrumental findings including contrast-enhanced tomography supported this hypothesis. The patient was stable for subsequent 10 days of the follow-up, which allowed for further conservative managements until the conventional time point for children with an atrial septal defect. Potential regress of the prominent EV, as well as natural growth of an infant and his/hers intracardiac structures, provide mostly favorable outcome without a surgical intervention. This was clearly illustrated in the clinical case.


2021 ◽  
Vol 23 (Supplement_D) ◽  
Author(s):  
Sahar El Shedoudy ◽  
Fatma Abo Elsoud ◽  
Eman El Dokhlaha ◽  
Reem Rashed ◽  
Mohammad Abdelghani

Abstract Objective to describe an approach to perform safe transcatheter closure of Atrial Septal Defect (ASD)/Patent Foramen Ovale (PFO) associated with large redundant Eustachian Valve. Background Transcatheter device closure of ASD/PFO is feasible in a great majority of patients. However, the presence of a huge mobile Eustachian Valve can compromise device placement. Patients and Methods Six patients (3 PFO and 3 ASD patients) with a huge redundant Eustachian valve were included. Two patients had PFO with long tunnel and were closed with Occlutech FigullaFlex II PFO occluders sized 23/25 and 27/30 respectively. The other PFO patient had an associated atrial septal aneurysm (ASA) and was closed with a 25 mm Amplatzer Multi-Fenestrated Septal Occluder “cribriform” device (St. Jude Medical – Abbott Vascular). The three ASDs were closed by regular ASD occluders (2 Flex II ASD Occluders sized 30 and 33 mm and 1 Amplatzer ASD Occluder sized 24 mm). Eustachian valve was successfully held with a steerable ablation catheter to deflect it against the lateral right atrial wall, keeping it away from the inter-atrial septum to prevent its entrapment or interference with the cable, the sheath or the device. Results All ASDs/PFOs have been successfully closed with no complications with free inferior vena cava (IVC) flow, with no residual inter-atrial shunt and the eustachian valve is not interfering with the device. Conclusions Safe percutaneous ASD/PFO closure can be achieved with proper control of a large redundant Eustachian valve.


Heart ◽  
2021 ◽  
pp. heartjnl-2021-319050
Author(s):  
Stephen J Dolgner ◽  
Zachary Louis Steinberg ◽  
Thomas K Jones ◽  
Mark Reisman ◽  
Jonathan Buber

ObjectiveTo evaluate the frequency of and risk factors for stroke as a presenting feature in adult patients with secundum atrial septal defect (ASD); rates of post-closure atrial fibrillation (AF) and stroke were also assessed.MethodsWe retrospectively reviewed adult patients who presented with an ASD between 2002 and 2018, excluding those with known atrial arrhythmias. Risk factors for stroke were identified using multivariable logistic regression. Post-closure stroke was evaluated using survival analysis stratified by the presence of post-procedure AF.ResultsOf 346 patients with ASD (median age 44 years), 34 (10%) presented with a history of stroke. Independent risk factors included elevated body mass index over 25 (OR: 18.2; 95% CI: 4.0 to 82.2; p<0.001), smoking (OR: 9.5; 95% CI: 3.8 to 23.9; p<0.001) and a prominent Eustachian valve (OR: 9.2; 95% CI: 3.4 to 25.2; p<0.001). A scoring system based on these three parameters provided robust stroke risk stratification. During a median follow-up of 12 months after closure, 12 patients (4%) experienced AF and 4 patients (1%) had a new stroke. AF was highly associated with development of stroke post-closure (p<0.001).ConclusionsIn this study population, the incidence of stroke prior to ASD closure among patients without atrial arrhythmias was 10%. Risk factors included obesity, smoking and prominent Eustachian valve anatomy. Lifestyle changes should be recommended for at-risk patients, and it may be reasonable to consider ASD closure in the absence of haemodynamic indications in patients at increased risk of stroke.


2021 ◽  
pp. 102705
Author(s):  
Branden Ireifej ◽  
David Song ◽  
Pradeeksha Mukuntharaj ◽  
Tasur Seen ◽  
Talal Almas ◽  
...  

Author(s):  
Harikrishnan Kurup ◽  
Arun Gopalakrishnan ◽  
Deepa Sasikumar ◽  
Venkatesh Gurajala ◽  
Kavasseri Krishnamoorthy

A prominent Eustachian valve in the right atrium has been reported to pose significant challenges during device closure of atrial septal defects. We describe the procedural aspects of device closure in an ASD with deficient rims and a redundant Eustachian valve. The prominent Eustachian valve provided extra stability in the anteroinferior aspect during device deployment and hence proved to be helpful for the procedure. It is important to consider this aspect while planning device closure


2021 ◽  
Vol 14 (6) ◽  
pp. e242553
Author(s):  
Dilpat Kumar ◽  
James Boyer ◽  
Warsha Fnu ◽  
Harry Boamah

A 46-year-old woman with a history of end-stage renal disease on chronic haemodialysis presented with 1 week of fever, chills, altered mental status and hand pain. She was febrile and ill-appearing on presentation with a pulse rate of 102 beats per minute. She had a tunnelled dialysis catheter in her right neck. Hand examination demonstrated a swollen, erythematous and tender wrist. Cardiovascular examination demonstrated no murmurs. CT of the hand showed abscesses involving the left forearm. Blood and abscess cultures grew methicillin-resistant Staphylococcus aureus (MRSA). Transesophageal echocardiography (TEE) showed a 1.0×1.0 cm mobile vegetation involving the eustachian valve (EV), confirming EV endocarditis. She remained bacteraemic for 18 days despite being on vancomycin with appropriate blood levels. Vancomycin was switched to daptomycin and ceftaroline, which cleared her cultures. Repeat TEE showed improved vegetation size. Our case highlights the rarity and management of EV endocarditis and the importance of synergy for treatment of persistent MRSA bacteraemia.


Author(s):  
Reuben Lamiaki Kynta ◽  
Sanjib Rawat ◽  
Bifica Sofia Lyngdoh ◽  
Arun Kumar Gunasekaran ◽  
Vanlalmalsawmdawngliana Fanai ◽  
...  

2021 ◽  
Vol 28 (3) ◽  
pp. 498-499
Author(s):  
Stylianos A. Karvounaris ◽  
Georgios S. Papaetis ◽  
Petros P. Mavrommatis

Sign in / Sign up

Export Citation Format

Share Document