beijing synchrotron radiation facility
Recently Published Documents


TOTAL DOCUMENTS

36
(FIVE YEARS 2)

H-INDEX

7
(FIVE YEARS 0)

2018 ◽  
Vol 410 (27) ◽  
pp. 7221-7228
Author(s):  
Jian Fu ◽  
Xianhong Shi ◽  
Qingxi Yuan ◽  
Wanxia Huang ◽  
Wei Guo ◽  
...  

2017 ◽  
Vol 24 (5) ◽  
pp. 1000-1005 ◽  
Author(s):  
Guang Chen ◽  
Shengqi Chu ◽  
Tianxi Sun ◽  
Xuepeng Sun ◽  
Lirong Zheng ◽  
...  

A confocal fluorescence endstation for depth-resolved micro-X-ray absorption spectroscopy is described. A polycapillary half-lens defines the incident beam path and a second polycapillary half-lens at 90° defines the probe sample volume. An automatic alignment program based on an evolutionary algorithm is employed to make the alignment procedure efficient. This depth-resolved system was examined on a general X-ray absorption spectroscopy (XAS) beamline at the Beijing Synchrotron Radiation Facility. Sacrificial red glaze (AD 1368–1644) china was studied to show the capability of the instrument. As a mobile endstation to be applied on multiple beamlines, the confocal system can improve the function and flexibility of general XAS beamlines, and extend their capabilities to a wider user community.


2017 ◽  
Vol 24 (3) ◽  
pp. 667-673 ◽  
Author(s):  
Hao Wang ◽  
Can Yu ◽  
Xu Wei ◽  
Zhenhua Gao ◽  
Guang-Lei Xu ◽  
...  

A new setup and commissioning of transient X-ray absorption spectroscopy are described, based on the high-repetition-rate laser pump/X-ray probe method, at the 1W2B wiggler beamline at the Beijing Synchrotron Radiation Facility. A high-repetition-rate and high-power laser is incorporated into the setup with in-house-built avalanche photodiodes as detectors. A simple acquisition scheme was applied to obtain laser-on and laser-off signals simultaneously. The capability of picosecond transient X-ray absorption spectroscopy measurement was demonstrated for a photo-induced spin-crossover iron complex in 6 mM solution with 155 kHz repetition rate.


2017 ◽  
Vol 24 (1) ◽  
pp. 367-373 ◽  
Author(s):  
Shibo Xi ◽  
Lucas Santiago Borgna ◽  
Lirong Zheng ◽  
Yonghua Du ◽  
Tiandou Hu

In this report, AI-BL1.0, an open-source Labview-based program for automatic on-line beamline optimization, is presented. The optimization algorithms used in the program are Genetic Algorithm and Differential Evolution. Efficiency was improved by use of a strategy known as Observer Mode for Evolutionary Algorithm. The program was constructed and validated at the XAFCA beamline of the Singapore Synchrotron Light Source and 1W1B beamline of the Beijing Synchrotron Radiation Facility.


2016 ◽  
Vol 23 (3) ◽  
pp. 830-835 ◽  
Author(s):  
Da-Rui Sun ◽  
Guang-Lei Xu ◽  
Bing-Bing Zhang ◽  
Xue-Yan Du ◽  
Hao Wang ◽  
...  

The implementation of a laser pump/X-ray probe scheme for performing picosecond-resolution X-ray diffraction at the 1W2B wiggler beamline at Beijing Synchrotron Radiation Facility is reported. With the hybrid fill pattern in top-up mode, a pixel array X-ray detector was optimized to gate out the signal from the singlet bunch with interval 85 ns from the bunch train. The singlet pulse intensity is ∼2.5 × 106 photons pulse−1at 10 keV. The laser pulse is synchronized to this singlet bunch at a 1 kHz repetition rate. A polycapillary X-ray lens was used for secondary focusing to obtain a 72 µm (FWHM) X-ray spot. Transient photo-induced strain in BiFeO3film was observed at a ∼150 ps time resolution for demonstration.


2015 ◽  
Vol 44 (1) ◽  
pp. 1-11 ◽  
Author(s):  
Rong Du ◽  
Quan Cai ◽  
Zhongjun Chen ◽  
Yu Gong ◽  
Hong Liu ◽  
...  

2014 ◽  
Vol 101 ◽  
pp. 1-5 ◽  
Author(s):  
L. Zheng ◽  
Y.D. Zhao ◽  
K. Tang ◽  
C.Y. Ma ◽  
C.H. Hong ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document