surface testing
Recently Published Documents


TOTAL DOCUMENTS

122
(FIVE YEARS 3)

H-INDEX

8
(FIVE YEARS 0)

2021 ◽  
Author(s):  
Wei Yan ◽  
Peiji Guo ◽  
Xi Chen ◽  
Yuting Xu


2021 ◽  
Author(s):  
Brenden Grove ◽  
Jacob McGregor ◽  
Rory DeHart ◽  
Ron Dusterhoft ◽  
Neil Stegent ◽  
...  

Abstract Hydraulically fractured completions dominate industry perforating activity, particularly in North American land basins. This has led to the development of fracture-optimized perforating systems in recent years. Aside from overarching safety, reliability, and efficiency priorities, the main technical performance attribute of these systems is consistent hole size in the casing, driven by limited entry fracture design considerations. While the industry continues to seek further improvements in hole size consistency, attention is also being directed to the perforations more holistically, from a perspective of maximizing the effectiveness of subsequent hydraulic fracturing and ultimately production operations. To this end, this paper presents two related activities addressing the development, qualification, and optimization of perf-for-frac systems. The first is a surface testing protocol used to characterize perforating system performance, in particular casing hole size and consistency. The second is a laboratory program, recently conducted to investigate perforating stressed Eagle Ford shale samples at downhole conditions. This program explored the influences of charge size, formation lamination direction, pore fluid, and dynamic underbalance on perforation characteristics. Casing hole size was also assessed. For the first activity (surface testing), we find that using cement-backed casing can be an important feature to ensure more downhole-realistic results. For the second activity (laboratory program), perforation casing hole sizes for the charges tested were in line with expectations based on existing surface test data, exhibiting negligible pressure dependency. Corresponding penetration depths into the stressed shale samples generally ranged from 3.5-in to 5-in, which is much shallower than might be expected based on surface concrete performance. Dynamic underbalance was found to exhibit some slight effect on the tunnel fill characteristics, while pore system fluid was found to have minimal influence on the results. An interesting feature of the perforated samples was the complex fracture network at the perforation tips, which appeared "propped" to some extent with charge liner debris. Some of these fractures were formation beds which had delaminated during the shot, a phenomenon observed for perforations both parallel and perpendicular to the laminations. The implications of these results to the downhole environment continues to be assessed. Of particular interest is the impact these phenomena might have on fracture initiation, formation breakdown, and treatment stages which accompany subsequent hydraulic fracturing pumping operations.



Cancer ◽  
2021 ◽  
Author(s):  
Mansi R. Shah ◽  
Imraan Jan ◽  
Jeremy Johns ◽  
Kuldip Singh ◽  
Pallavi Kumar ◽  
...  


2020 ◽  
Vol 28 (24) ◽  
pp. 36706
Author(s):  
Daniel Aguirre-Aguirre ◽  
Brenda Villalobos-Mendoza ◽  
Rufino Díaz-Uribe ◽  
Manuel Campos-García


Blood ◽  
2020 ◽  
Vol 136 (Supplement 1) ◽  
pp. 24-25
Author(s):  
Mansi R Shah ◽  
Imraan Jan ◽  
Jeremy Johns ◽  
Kuldip Singh ◽  
Pallavi Kumar ◽  
...  

Introduction: Current evidence suggests that the COVID-19 related mortality and morbidity is higher in cancer patients due to increased visits to healthcare facilities (e.g., doctor's visits, phlebotomy, imaging, social work, financial consultations, therapy administration, etc) and inherent or therapy-induced immunosuppression. Patients with hematologic malignancies harboring SARS-CoV-2 have the highest mortality compared with other cancer patients. Although COVID-19 is knowingly transmitted person to person via respiratory droplets, there is potential for infection from contact with surfaces (e.g. plastic, metal, cardboard, etc) polluted with fomites that have been shown to have viable virus up to 72 hours in laboratory settings (Van Doremalen et al. NEJM 2020). The risk of nosocomial infections is hypothesized to be due to environmental contact and contamination, but there are no real-world analyses that exist that demonstrate the impact of recently established infection control policies (e.g., strict use of personal protective equipment (PPE), social distancing, hand hygiene, disinfectant protocols, etc) in hematology/oncology patient settings. This study evaluated the frequency of SARS-CoV-2 on a multitude of environmental surfaces in outpatient and inpatient settings in a large tertiary COVID-19 referral cancer center in New Jersey. Methods: IRB approval was obtained to conduct the study in a COVID-19 referral center in 2 large, freestanding outpatient clinics (i.e., malignant hematology and medical oncology) and co-localized infusion suites as well as two physically separated inpatient units (i.e., a leukemia/lymphoma/CART unit and an active COVID-19 floor, the latter housing cancer patients actively infected with SARS-CoV-2 and persons under investigation (PUI) for infection). Surface testing for viral RNA in the outpatient infusions suites included spaces where several patients with recent SARS-CoV-2 infection were receiving cancer treatment in the outpatient setting. High-impact areas were selected based on frequency of use, patient and healthcare provider contact, and risk of contamination from COVID-19 positive subjects (COVID-19+) and PUIs due to virus transmissibility. Surfaces were sampled on Mondays, Wednesdays and Fridays from 6/17/20 through 6/29/20 prior to scheduled cleaning and disinfection services, but after patient or staff use, following WHO protocols for COVID-19 surface sampling. Specimens were analyzed with real-time reverse transcriptase PCR analysis. Results: Overall, 204 total environmental samples were collected over the study period. Testing sites were categorized as 1) Public areas (waiting rooms, infusion areas, bathrooms, floors, elevator banks, doors, and exam rooms included designated isolation rooms for known COVID-19+/PUIs); 2) Staff areas (computer equipment, pneumatic tubing stations, pharmacy bench, and medication rooms); and 3) Medical equipment (IV poles, chemotherapy bags, vitals monitor, telemetry stations, and linen carts). Among the 130 surfaces examined from the two outpatient hematology-oncology clinics and 36 tests from the inpatient leukemia/lymphoma/CART cell unit, all 166 surfaces were negative for SARS-CoV-2 viral RNA (see Table). Among the inpatient COVID-19+ and PUI units, one of 38 samples were positive (2.6%). The one positive sample was taken from the floor of an elderly patient with multiple medical comorbidities being treated with remdesevir, dexamethasone, and apixaban for SARS-CoV-2 pneumonia. Altogether, the positive test rate for SARS-CoV-2 RNA across all surfaces in the combined outpatient and inpatient hematology/oncology units was 0.5% (1/204). Discussion : This systematic investigation of 'real world' environmental surfaces performed in outpatient and inpatient hematology-oncology units revealed overall negligible detection of active SARS-CoV-2 RNA. It highlights the efficacy of current, detailed infection control policies (e.g., screening, nursing-directed triage for PUIs/COVID-19+ patients, visitor restriction, telehealth, social distancing, and disinfection protocols) and should also mitigate concerns of healthcare providers and patients, particularly those in the healthcare setting with blood disorders. Additionally, the one positive sample from a COVID-19 unit emphasizes the need for physical separation of patients with SARS-CoV-2. Disclosures Evens: Research To Practice: Honoraria, Speakers Bureau; Merck: Consultancy, Honoraria, Research Funding; Pharmacyclics: Consultancy, Honoraria; Novartis: Consultancy, Honoraria; MorphoSys: Consultancy, Honoraria; Abbvie: Consultancy, Honoraria; Seattle Genetics: Consultancy, Honoraria, Research Funding; Epizyme: Consultancy, Honoraria, Research Funding; Mylteni: Consultancy, Honoraria.



2020 ◽  
Vol 41 (11) ◽  
pp. 1328-1330 ◽  
Author(s):  
Kyeong Seob Shin ◽  
Hee Sue Park ◽  
Jisu Lee ◽  
Joon Kee Lee

AbstractEnvironmental surface testing was performed to search for evidence of severe acute respiratory coronavirus virus 2 (SARS-CoV-2) environmental contamination by an asymptomatic SARS-CoV-2 carrier with persistently high viral loads under isolation. No evidence of environmental contamination was found. Further studies are needed to measure environmental contamination by SARS-CoV-2 carriers and to determine reasonable isolation periods.



2020 ◽  
Vol 40 (8) ◽  
pp. 0822001
Author(s):  
戚丽丽 Qi Lili ◽  
郑列华 Zheng Liehua ◽  
叶璐 Ye Lu ◽  
张金平 Zhang Jinping


2019 ◽  
Vol 444 ◽  
pp. 21-27 ◽  
Author(s):  
Jinming Gao ◽  
Hua Shen ◽  
Jia Li ◽  
Yue Sun ◽  
Xiangqun Cui ◽  
...  


Sign in / Sign up

Export Citation Format

Share Document