Journal of Oral Implants
Latest Publications


TOTAL DOCUMENTS

4
(FIVE YEARS 0)

H-INDEX

2
(FIVE YEARS 0)

Published By Hindawi Limited

2314-6575, 2356-7546

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Yves Reingewirtz ◽  
Henri Tenenbaum

Aim. Several limiting factors encourage the clinician to use short implants. Among those, the presence of limiting anatomical elements and the simplification of surgical procedures are particularly significant. The goal of this study is to analyse the opportunity to extend the use of short implants to extrashort implants with a length less than 5 mm (ESI). Materials and Methods. Seven patients (3 women, 4 men; mean age 60.4 years) received extrashort implants (Straumann Implant, Palatal Orthosystem, length 4.2 mm, diameter 4.1 or 4.8 mm) in severe resorbed edentulous posterior areas. The implants were incorporated in partially fixed dentures. The osseous stability and the attachment level were recorded after a loading period of 22 to 54 months. Results. The results demonstrated a success rate of 100%, stability in the osseous level surrounding implants (mean annual mesial and distal loss of 0.026 mm and 0.105 mm, resp.), and no significant differences in the mean attachment depth between extrashort implants and contralateral teeth or implants (3.7 mm versus 3.55 mm, SD = 0.87). Splinting ESI with natural teeth resulted in significantly more bone resorption than with other implants (P=0.001). Conclusion. This exploratory study on the use of extrashort implants demonstrated good reliability over a loading period of 22 to 54 months.


2015 ◽  
Vol 2015 ◽  
pp. 1-14 ◽  
Author(s):  
Michela Bruschi ◽  
Doris Steinmüller-Nethl ◽  
Walter Goriwoda ◽  
Michael Rasse

Since Brånemark discovered the favorable effects of titanium in bone healing in 1965, titanium has emerged as the gold standard bulk material for present-time dental implantology. In the course of years researchers aimed for improvement of the implants performance in bone even at compromised implant sites and multiple factors were investigated influencing osseointegration. This review summarizes and clarifies the four factors that are currently recognized being relevant to influence the tissue-implant contact ratio: bulk materials and coatings, topography, surface energy, and biofunctionalization. The macrodesigns of bulk materials (e.g., titanium, zirconium, stainless steel, tantalum, and magnesium) provide the mechanical stability and their influence on bone cells can be additionally improved by surface treatment with various materials (calcium phosphates, strontium, bioglasses, diamond-like carbon, and diamond). Surface topography can be modified via different techniques to increase the bone-implant contact, for example, plasma-spraying, grit-blasting, acid-etching, and microarc oxidation. Surface energy (e.g., wettability and polarity) showed a strong effect on cell behavior and cell adhesion. Functionalization with bioactive molecules (via physisorption, covalent binding, or carrier systems) targets enhanced osseointegration. Despite the satisfying clinical results of presently used dental implant materials, further research on innovative implant surfaces is inevitable to pursuit perfection in soft and hard tissue performance.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Pavankumar Janardan Vibhute ◽  
Pushkar A. Patil

Objective of this retrospective study was to measure cortical bone thickness and lowest level of maxillary sinus at maxillary posterior quadrant in different growth pattern (hypodivergent, average, and hyperdivergent) at prospective microimplant placement sites in order to understand both safety and stability aspects of microimplant placement by using cone-beam 3-dimensional computed tomographic images. In posterior quadrant, vertical distance from cementoenamel junction to lowest level of maxillary sinus at interradicular region was measured. Buccal cortical bone thickness was measured at 3 different vertical levels at interradicular space. The cortical bone thickness was found more at sinus floor level and above it than below the sinus floor. In perspective of miniscrew placement, study shows that maxillary sinus floor is safer with average and hyperdivergent growth pattern than hypodivergent growth pattern. In the proximity of maxillary sinus floor, 1 mm or more cortical bone can be expected in maxillary posterior region in average and hyperdivergent growth patterns. However, it was thicker in hypodivergent than hyperdivergent growth patterns. Hypodivergent patients require either more horizontal insertion (more parallel to occlusal plane) or shorter length of miniscrew to avoid damage to maxillary sinus.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Bernhard Pommer ◽  
Lavinia Bucur ◽  
Konstantin Zauza ◽  
Gabor Tepper ◽  
Markus Hof ◽  
...  

Dental implant fracture is a rare biomechanical complication, however, one of the most serious and frustating ones as it is generally associated with implant and prosthesis failure as well as the surgical hazards of explantation and reimplantation. To gain insights into implant fracture rates and the impact of patient-, surgery-, and prosthetic-related factors, systematic review and meta-analysis of the English literature were performed. Electronic and hand searches yielded 69 relevant publications reporting on 827 fractures out of 44521 implants investigated. The overall incidence of implant fractures was 1.6%. Mean patient age at the time of implant fracture was 54 ± 11 years, and 70% occurred in males. The vast majority (85%) occurred in posterior regions of the mouth (premolar or molar positions). No tendency of increased fracture rates could be noted for short implant lengths or narrow implant diameters. Implant fractures occurred after 4.1 ± 3.5 years of loading, on average, in most cases (88%) supporting fixed restorations; however, only 56% were preceded by screw loosening. Although further investigations are needed to fully explore the characteristics and causes of this rare complication, it can be concluded that no more than 2.8% of implants fracture is within a mean loading period of 8.3 years.


Sign in / Sign up

Export Citation Format

Share Document