scholarly journals Procedure for optimal implementation of automatic tube potential selection in pediatric CT to reduce radiation dose and improve workflow

Author(s):  
Jacinta E. Browne ◽  
Michael R. Bruesewitz ◽  
Vrieze Thomas ◽  
Kristen B. Thomas ◽  
Nathan C. Hull ◽  
...  
2015 ◽  
Vol 26 (1) ◽  
pp. 157-166 ◽  
Author(s):  
Michael F. Brinkley ◽  
Juan C. Ramirez-Giraldo ◽  
Ehsan Samei ◽  
Daniel J. Frush ◽  
Kingshuk Roy Choudhury ◽  
...  

Radiographics ◽  
2011 ◽  
Vol 31 (3) ◽  
pp. 835-848 ◽  
Author(s):  
Lifeng Yu ◽  
Michael R. Bruesewitz ◽  
Kristen B. Thomas ◽  
Joel G. Fletcher ◽  
James M. Kofler ◽  
...  

2009 ◽  
Vol 192 (5) ◽  
pp. 1292-1303 ◽  
Author(s):  
Mervyn D. Cohen

2010 ◽  
Vol 51 (3) ◽  
pp. 260-270 ◽  
Author(s):  
Peter Björkdahl ◽  
Ulf Nyman

Background: Concern has been raised regarding the mounting collective radiation doses from computed tomography (CT), increasing the risk of radiation-induced cancers in exposed populations. Purpose: To compare radiation dose and image quality in a chest phantom and in patients for the diagnosis of pulmonary embolism (PE) at 100 and 120 peak kilovoltage (kVp) using 16-multichannel detector computed tomography (MDCT). Material and Methods: A 20-ml syringe containing 12 mg I/ml was scanned in a chest phantom at 100/120 kVp and 25 milliampere seconds (mAs). Consecutive patients underwent 100 kVp ( n = 50) and 120 kVp ( n = 50) 16-MDCT using a “quality reference” effective mAs of 100, 300 mg I/kg, and a 12-s injection duration. Attenuation (CT number), image noise (1 standard deviation), and contrast-to-noise ratio (CNR; fresh clot = 70 HU) of the contrast medium syringe and pulmonary arteries were evaluated on 3-mm-thick slices. Subjective image quality was assessed. Computed tomography dose index (CTDIvol) and dose–length product (DLP) were presented by the CT software, and effective dose was estimated. Results: Mean values in the chest phantom and patients changed as follows when X-ray tube potential decreased from 120 to 100 kVp: attenuation +23% and +40%, noise +38% and +48%, CNR −6% and 0%, and CTDIvol −38% and −40%, respectively. Mean DLP and effective dose in the patients decreased by 42% and 45%, respectively. Subjective image quality was excellent or adequate in 49/48 patients at 100/120 kVp. No patient with a negative CT had any thromboembolism diagnosed during 3-month follow-up. Conclusion: By reducing X-ray tube potential from 120 to 100 kVp, while keeping all other scanning parameters unchanged, the radiation dose to the patient may be almost halved without deterioration of diagnostic quality, which may be of particular benefit in young individuals.


Author(s):  
Don Johnson Nocum ◽  
John Robinson ◽  
Mark Halaki ◽  
Magnus Bath ◽  
John D. Thompson ◽  
...  

Abstract This study sought to achieve radiation dose reductions for patients receiving uterine artery embolisation (UAE) by evaluating radiation dose measurements for the preceding generation (Allura) and upgraded (Azurion) angiography system. Previous UAE regression models in the literature could not be applied to this centre’s practice due to being based on different angiography systems and radiation dose predictor variables. The aims of this study were to establish whether radiation dose is reduced with the upgraded angiography system and to develop a regression model to determine predictors of radiation dose specific to the upgraded angiography system. A comparison between Group I (Allura, n = 95) and Group II (Azurion, n = 95) demonstrated a significant reduction in KAP (kerma-area product) and Ka, r (reference air kerma) by 63% (143.2 Gy·cm2 vs 52.9 Gy·cm2; P < 0.001, d = 0.8) and 67% (0.6 Gy vs 0.2 Gy; P < 0.001, d = 0.8), respectively. The multivariable linear regression (MLR) model identified the UAE radiation dose predictors for KAP on the upgraded angiography system as total fluoroscopy dose, Ka, r, and total uterus volume. The predictive accuracy of the MLR model was assessed using a Bland-Altman plot. The mean difference was 0.39 Gy·cm2 and the limits of agreement (LoA) were +28.49 and -27.71 Gy·cm2, and thus illustrated no proportional bias. Our findings validated the upgraded angiography system and its advance capabilities to significantly reduce radiation dose for our patients. Interventional radiologist and interventional radiographer familiarisation of the system’s features and the implementation of the newly established MLR model would further facilitate dose optimisation for all centres performing UAE procedures using the upgraded angiography system.


Sign in / Sign up

Export Citation Format

Share Document