Reverse‐Engineered Highly Conformable, Leak and Pressure Reducing Cushion for Neonatal Resuscitation Mask

2021 ◽  
pp. 2101364
Author(s):  
Carolyn M. McGann ◽  
Young‐Joo Lee ◽  
Se‐Um Kim ◽  
Danielle D. Weinberg ◽  
Xincheng Zha ◽  
...  
PEDIATRICS ◽  
2016 ◽  
Vol 137 (Supplement 3) ◽  
pp. 448A-448A
Author(s):  
Catherine O'Neill Buck ◽  
Myra H. Wyckoff ◽  
L. Steven Brown ◽  
Vishal Kapadia

Children ◽  
2021 ◽  
Vol 8 (7) ◽  
pp. 594
Author(s):  
Amy L. Lesneski ◽  
Payam Vali ◽  
Morgan E. Hardie ◽  
Satyan Lakshminrusimha ◽  
Deepika Sankaran

Neonatal resuscitation (NRP) guidelines suggest targeting 85–95% preductal SpO2 by 10 min after birth. Optimal oxygen saturation (SpO2) targets during resuscitation and in the post-resuscitation management of neonatal meconium aspiration syndrome (MAS) with persistent pulmonary hypertension (PPHN) remains uncertain. Our objective was to compare the time to reversal of ductal flow from fetal pattern (right-to-left), to left-to-right, and to evaluate pulmonary (QPA), carotid (QCA)and ductal (QDA) blood flows between standard (85–94%) and high (95–99%) SpO2 targets during and after resuscitation. Twelve lambs asphyxiated by endotracheal meconium instillation and cord occlusion to induce MAS and PPHN were resuscitated per NRP guidelines and were randomized to either standard (85–94%) or high (95–99%) SpO2 targets. Out of twelve lambs with MAS and PPHN, six each were randomized to standard and high SpO2 targets. Median [interquartile range] time to change in direction of blood flow across the ductus arteriosus from right-to-left, to left-to-right was significantly shorter with high SpO2 target (7.4 (4.4–10.8) min) compared to standard SpO2 target (31.5 (21–66.2) min, p = 0.03). QPA was significantly higher during the first 10 min after birth with higher SpO2 target. At 60 min after birth, the QPA, QCA and QDA were not different between the groups. To conclude, targeting SpO2 of 95–99% during and after resuscitation may hasten reversal of ductal flow in lambs with MAS and PPHN and transiently increase QPA but no differences were observed at 60 min. Clinical studies comparing low and high SpO2 targets assessing hemodynamics and neurodevelopmental outcomes are warranted.


Children ◽  
2021 ◽  
Vol 8 (6) ◽  
pp. 526
Author(s):  
James Ditai ◽  
Aisling Barry ◽  
Kathy Burgoine ◽  
Anthony K. Mbonye ◽  
Julius N. Wandabwa ◽  
...  

The initial bedside care of premature babies with an intact cord has been shown to reduce mortality; there is evidence that resuscitation of term babies with an intact cord may also improve outcomes. This process has been facilitated by the development of bedside resuscitation surfaces. These new devices are unaffordable, however, in most of sub-Saharan Africa, where 42% of the world’s 2.4 million annual newborn deaths occur. This paper describes the rationale and design of BabySaver, an innovative low-cost mobile resuscitation unit, which was developed iteratively over five years in a collaboration between the Sanyu Africa Research Institute (SAfRI) in Uganda and the University of Liverpool in the UK. The final BabySaver design comprises two compartments; a tray to provide a firm resuscitation surface, and a base to store resuscitation equipment. The design was formed while considering contextual factors, using the views of individual women from the community served by the local hospitals, medical staff, and skilled birth attendants in both Uganda and the UK.


Author(s):  
Catherine M. Groden ◽  
Erwin T. Cabacungan ◽  
Ruby Gupta

Objective The authors aim to compare all code blue events, regardless of the need for chest compressions, in the neonatal intensive care unit (NICU) versus the pediatric intensive care unit (PICU). We hypothesize that code events in the two units differ, reflecting different disease processes. Study Design This is a retrospective analysis of 107 code events using the code narrator, which is an electronic medical record of real-time code documentation, from April 2018 to March 2019. Events were divided into two groups, NICU and PICU. Neonatal resuscitation program algorithm was used for NICU events and a pediatric advanced life-support algorithm was used for PICU events. Events and outcomes were compared using univariate analysis. The Mann–Whitney test and linear regressions were done to compare the total code duration, time from the start of code to airway insertion, and time from airway insertion to end of code event. Results In the PICU, there were almost four times more code blue events per month and more likely to involve patients with seizures and no chronic condition. NICU events more often involved ventilated patients and those under 2 months of age. The median code duration for NICU events was 2.5 times shorter than for PICU events (11.5 vs. 29 minutes), even when adjusted for patient characteristics. Survival to discharge was not different in the two groups. Conclusion Our study suggests that NICU code events as compared with PICU code events are more likely to be driven by airway problems, involve patients <2 months of age, and resolve quickly once airway is taken care of. This supports the use of a ventilation-focused neonatal resuscitation program for patients in the NICU. Key Points


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Junette Arlette Mbengono Metogo ◽  
Theophile Njamen Nana ◽  
Brian Ajong Ngongheh ◽  
Emelinda Berinyuy Nyuydzefon ◽  
Christoph Akazong Adjahoung ◽  
...  

Abstract Background Acute foetal distress (AFD) is a life-threatening foetal condition complicating 2% of all pregnancies and accounting for 8.9% of caesarean sections (CS) especially in developing nations. Despite the severity of the problem, no evidence exists as to the safest anaesthetic technique for the mother and foetus couple undergoing CS for AFD. We aimed to compare general anaesthesia (GA) versus regional (spinal and epidural) anaesthesia in terms of their perioperative maternal and foetal outcomes. Methods We carried out a retrospective cohort study by reviewing the medical records of all women who underwent CS indicated for AFD between 2015 to 2018 at the Douala General Hospital, Cameroon. Medical records of neonates were also reviewed. We sought to investigate the association between GA, and regional anaesthesia administered during CS for AFD and foetal and maternal outcomes. The threshold of statistical significance was set at 0.05. Results We enrolled the medical records of 117 pregnant women who underwent CS indicated for AFD. Their mean age and mean gestational age were 30.5 ± 4.8 years and 40 weeks respectively. Eighty-three (70.9%), 29 (24.8%) and 05 (4.3%) pregnant women underwent CS under SA, GA and EA respectively. Neonates delivered by CS under GA were more likely to have a significantly low APGAR score at both the 1st (RR = 1.93, p = 0.014) and third-minute (RR = 2.52, p = 0.012) and to be resuscitated at birth (RR = 2.15, p = 0.015). Past CS, FHR pattern on CTG didn’t affect these results in multivariate analysis. Adverse maternal outcomes are shown to be higher following SA when compared to GA. Conclusion The study infers an association between CS performed for AFD under GA and foetal morbidity. This, however, failed to translate into a difference in perinatal mortality when comparing GA vs RA. This finding does not discount the role of GA, but we emphasize the need for specific precautions like adequate anticipation for neonatal resuscitation to reduce neonatal complications associated with CS performed for AFD under GA.