Diffuse signal abnormalities in the spinal cord in multiple sclerosis: Direct postmortem in situ magnetic resonance imaging correlated with in vitro high-resolution magnetic resonance imaging and histopathology

2002 ◽  
Vol 51 (5) ◽  
pp. 652-656 ◽  
Author(s):  
Elisabeth Bergers ◽  
Joost C. J. Bot ◽  
Paul van der Valk ◽  
Jonas A. Castelijns ◽  
Geert J. Lycklama A Nijeholt ◽  
...  
2015 ◽  
Vol 22 (3) ◽  
pp. 320-328 ◽  
Author(s):  
Adrienne N Dula ◽  
Siddharama Pawate ◽  
Richard D Dortch ◽  
Robert L Barry ◽  
Kristen M George-Durrett ◽  
...  

Background: The clinical course of multiple sclerosis (MS) is mainly attributable to cervical and upper thoracic spinal cord dysfunction. High-resolution, 7T anatomical imaging of the cervical spinal cord is presented. Image contrast between gray/white matter and lesions surpasses conventional, clinical T1- and T2-weighted sequences at lower field strengths. Objective: To study the spinal cord of healthy controls and patients with MS using magnetic resonance imaging at 7T. Methods: Axial (C2–C5) T1- and T2*-weighted and sagittal T2*-/spin-density-weighted images were acquired at 7T in 13 healthy volunteers (age 22–40 years), and 15 clinically diagnosed MS patients (age 19–53 years, Extended Disability Status Scale, (EDSS) 0–3) in addition to clinical 3T scans. In healthy volunteers, a high-resolution multi-echo gradient echo scan was obtained over the same geometry at 3T. Evaluation included signal and contrast to noise ratios and lesion counts for healthy and patient volunteers, respectively. Results/conclusion: High-resolution images at 7T exceeded resolutions reported at lower field strengths. Gray and white matter were sharply demarcated and MS lesions were more readily visualized at 7T compared to clinical acquisitions, with lesions apparent at both fields. Nerve roots were clearly visualized. White matter lesion counts averaged 4.7 vs 3.1 (52% increase) per patient at 7T vs 3T, respectively ( p=0.05).


2021 ◽  
Author(s):  
Kilian Maria Arthur Mueller ◽  
Geoffrey Topping ◽  
Sebastian Patrick Schwaminger ◽  
Younzhe Zou ◽  
Diana Marcela Rojas-González ◽  
...  

Melt electrowriting (MEW) is a high-resolution fiber-forming technology for the digital fabrication of complex micro-structured scaffolds for tissue engineering, which has convincingly shown its potential in in vitro and in...


1992 ◽  
Vol 32 (5) ◽  
pp. 643-650 ◽  
Author(s):  
S. Wiebe ◽  
D. H. Lee ◽  
S. J. Karlik ◽  
M. Hopkins ◽  
M. K. Vandervoort ◽  
...  

2005 ◽  
Vol 57 (4) ◽  
pp. 606-607 ◽  
Author(s):  
Tijmen Korteweg ◽  
Frederik Barkhof ◽  
Bernard M. J. Uitdehaag ◽  
Chris H. Polman

2007 ◽  
Vol 25 (1) ◽  
pp. 1-7 ◽  
Author(s):  
Yoshihide Kanemaki ◽  
Yasuyuki Kurihara ◽  
Kyoko Okamoto ◽  
Yasuo Nakajima ◽  
Mamoru Fukuda ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document