Electrochemical Label-Free Nucleotide Sensors

2015 ◽  
Vol 10 (12) ◽  
pp. 2560-2573 ◽  
Author(s):  
Hiroshi Aoki
Sensors ◽  
2019 ◽  
Vol 19 (24) ◽  
pp. 5409 ◽  
Author(s):  
Filip Kveton ◽  
Anna Blsakova ◽  
Lenka Lorencova ◽  
Monika Jerigova ◽  
Dusan Velic ◽  
...  

The study describes development of a glycan biosensor for detection of a tumor-associated antibody. The glycan biosensor is built on an electrochemically activated/oxidized graphene screen-printed electrode (GSPE). Oxygen functionalities were subsequently applied for covalent immobilization of human serum albumin (HSA) as a natural nanoscaffold for covalent immobilization of Thomsen-nouvelle (Tn) antigen (GalNAc-O-Ser/Thr) to be fully available for affinity interaction with its analyte—a tumor-associated antibody. The step by step building process of glycan biosensor development was comprehensively characterized using a battery of techniques (scanning electron microscopy, atomic force microscopy, contact angle measurements, secondary ion mass spectrometry, surface plasmon resonance, Raman and energy-dispersive X-ray spectroscopy). Results suggest that electrochemical oxidation of graphene SPE preferentially oxidizes only the surface of graphene flakes within the graphene SPE. Optimization studies revealed the following optimal parameters: activation potential of +1.5 V vs. Ag/AgCl/3 M KCl, activation time of 60 s and concentration of HSA of 0.1 g L−1. Finally, the glycan biosensor was built up able to selectively and sensitively detect its analyte down to low aM concentration. The binding preference of the glycan biosensor was in an agreement with independent surface plasmon resonance analysis.


2020 ◽  
Vol 154 ◽  
pp. 112050 ◽  
Author(s):  
Mateusz Śmietana ◽  
Marcin Koba ◽  
Petr Sezemsky ◽  
Katarzyna Szot-Karpińska ◽  
Dariusz Burnat ◽  
...  

2013 ◽  
Vol 27 ◽  
pp. 104-107 ◽  
Author(s):  
Jan Vacek ◽  
Martina Zatloukalova ◽  
Marika Havlikova ◽  
Jitka Ulrichova ◽  
Martin Kubala

2015 ◽  
Vol 64 ◽  
pp. 74-80 ◽  
Author(s):  
Bicheng Zhu ◽  
Marsilea A. Booth ◽  
Phillip Shepherd ◽  
Allan Sheppard ◽  
Jadranka Travas-Sejdic

The Analyst ◽  
2015 ◽  
Vol 140 (12) ◽  
pp. 4089-4096 ◽  
Author(s):  
Isabel Álvarez-Martos ◽  
Rui Campos ◽  
Elena E. Ferapontova

An electrochemical label-free aptasensor monitors physiological levels of dopamine with improved sensitivity when the aptamer surface coverage is optimized and with no interference from other catecholamines.


Sign in / Sign up

Export Citation Format

Share Document