Pressure Drop and Mass Transfer Study in Static Mixers with Gas Continuous Phase

2008 ◽  
Vol 80 (4) ◽  
pp. 727-733 ◽  
Author(s):  
Annabelle Couvert ◽  
Marie-France Péculier ◽  
Alain Laplanche
Author(s):  
Dr. Mazhar Hussain

The hydrodynamic characteristics of mixing fluids are always the points to consider in improvement of their mixing quality especially using motionless mixers normally stated as “Static Mixers”. Motionless mixing technique was adopted for Air-Water system with the advantage of negligible power consumption over dynamic mixers. Different hydrodynamic characteristics were experimented using “Baffle Type” static element and were compared to those of already used in recent studies. Dissolved oxygen content, Static mixer geometry (i.e. Baffle, Blade, Wheel, Plate and Needle), mixing fluids flow rates were chosen as variables and selected in this content as rate of mass transfer study which founds out to be significant using “Baffle Type” static element. Volumetric mass transfer was also achieved at higher scale which gives a clear indication of increase the mass transfer coefficient in between the comparison of “Baffle type” element and other mentioned elements. Pressure droplet and depletion in Air bubble size across static elements were visually perceived using Hg-Manometer and still photography respectively. A mathematical model was also developed portraying the Air bubble diameter at different flow rates for this system. Other hydrodynamics like higher Dissolved Oxygen (DO) Content, Less Power consumption were also found to be more advantageous for “Baffle Type” static element.


2012 ◽  
Vol 98 ◽  
pp. 78-87 ◽  
Author(s):  
Chengna Dai ◽  
Zhigang Lei ◽  
Qunsheng Li ◽  
Biaohua Chen

1985 ◽  
Vol 50 (3) ◽  
pp. 745-757 ◽  
Author(s):  
Andreas Zahn ◽  
Lothar Ebner ◽  
Kurt Winkler ◽  
Jan Kratochvíl ◽  
Jindřich Zahradník

The effect of two-phase flow regime on decisive hydrodynamic and mass transfer characteristics of horizontal-tube gas-liquid reactors (pressure drop, liquid holdup, kLaL) was determined in a cocurrent-flow experimental unit of the length 4.15 m and diameter 0.05 m with air-water system. An adjustable-height weir was installed in the separation chamber at the reactor outlet to simulate the effect of internal baffles on reactor hydrodynamics. Flow regime maps were developed in the whole range of experimental gas and liquid flow rates both for the weirless arrangement and for the weir height 0.05 m, the former being in good agreement with flow-pattern boundaries presented by Mandhane. In the whole range of experi-mental conditions pressure drop data could be well correlated as a function of gas and liquid flow rates by an empirical exponential-type relation with specific sets of coefficients obtained for individual flow regimes from experimental data. Good agreement was observed between values of pressure drop obtained for weirless arrangement and data calculated from the Lockhart-Martinelli correlation while the contribution of weir to the overall pressure drop was well described by a relation proposed for the pressure loss in closed-end tubes. In the region of negligible weir influence values of liquid holdup were again succesfully correlated by the Lockhart-Martinelli relation while the dependence of liquid holdup data on gas and liquid flow rates obtained under conditions of significant weir effect (i.e. at low flow rates of both phases) could be well described by an empirical exponential-type relation. Results of preliminary kLaL measurements confirmed the decisive effect of the rate of energy dissipation on the intensity of interfacial mass transfer in gas-liquid dispersions.


ACS Omega ◽  
2020 ◽  
Vol 5 (45) ◽  
pp. 29209-29221
Author(s):  
Ping Yue ◽  
Hongnan Yang ◽  
Chuanjian He ◽  
G. M. Yu ◽  
James J. Sheng ◽  
...  

Author(s):  
Mahmoud Kamaleddine ◽  
Dr Charles Bonnin ◽  
Dr Typhène Michel ◽  
Dr Léna Brunet-Errard ◽  
Dr Joëlle Aubin ◽  
...  

1976 ◽  
Vol 98 (2) ◽  
pp. 297-302 ◽  
Author(s):  
K. G. T. Hollands ◽  
K. C. Goel

The general concept of the mean diameter of the disperse phase of an aerosol system, first introduced by Mugele and Evans in 1951, has proven to be a very useful one. In this concept, the proper mean diameter, xp,q, is characterized by a single pair of indices, p and q, which are dependent on the actual type of aerosol system under consideration. This paper re-examines the validity of this concept of mean diameter in heat and mass transfer aerosol systems. The concept is found to be applicable only under a very narrow range of conditions. Attention is then given to a more general definition of a mean diameter, applicable to aerosol heat or mass exchangers. Analyses of these devices shows that the more general mean diameter is a function of the capacity rate ratio, R, and effectiveness of the heat exchanger, ε. Solutions to the governing equations have permitted the mean diameter to be presented graphically as a function of these variables. These solutions are given for two types of particle size distributions, the Rosin-Rammler and the log-probability, and for both parallel-flow and counter-flow heat exchangers. The solutions are, however, restricted to cases where the resistance to heat or mass transfer lies exclusively in the continuous phase.


Sign in / Sign up

Export Citation Format

Share Document