Consistent floor response spectra for performance‐based seismic design of nonstructural elements

2020 ◽  
Vol 49 (3) ◽  
pp. 261-284 ◽  
Author(s):  
Roberto J. Merino ◽  
Daniele Perrone ◽  
Andre Filiatrault
Buildings ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 243
Author(s):  
Giammaria Gabbianelli ◽  
Daniele Perrone ◽  
Emanuele Brunesi ◽  
Ricardo Monteiro

The importance of non-structural elements in performance-based seismic design of buildings is presently widely recognized. These elements may significantly affect the functionality of buildings even for low seismic intensities, in particular for the case of critical facilities, such as hospital buildings. One of the most important issues to deal with in the seismic performance assessment of non-structural elements is the definition of the seismic demand. This paper investigates the seismic demand to which the non-structural elements of a case-study hospital building located in a medium–high seismicity region in Italy, are prone. The seismic demand is evaluated for two seismic intensities that correspond to the definition of serviceability limit states, according to Italian and European design and assessment guidelines. Peak floor accelerations, interstorey drifts, absolute acceleration, and relative displacement floor response spectra are estimated through nonlinear time–history analyses. The absolute acceleration floor response spectra are then compared with those obtained from simplified code formulations, highlighting the main shortcomings surrounding the practical application of performance-based seismic design of non-structural elements. The absolute acceleration floor response spectra are then compared with those obtained from simplified code formulations. The results, both in terms of absolute acceleration and relative displacement floor response spectra, highlighted the influence of the higher modes of the structure and the inaccuracy of the code provisions, pointing out the need for more accurate simplified methodologies for the practical application of performance-based seismic design of non-structural elements.


2020 ◽  
Vol 36 (2_suppl) ◽  
pp. 213-237
Author(s):  
Miguel A Jaimes ◽  
Adrián D García-Soto

This study presents an evaluation of floor acceleration demands for the design of rigid and flexible acceleration-sensitive nonstructural components in buildings, calculated using the most recent Mexico City seismic design provisions, released in 2017. This evaluation includes two approaches: (1) a simplified continuous elastic model and (2) using recordings from 10 instrumented buildings located in Mexico City. The study found that peak floor elastic acceleration demands imposed on rigid nonstructural components into buildings situated in Mexico City might reach values of 4.8 and 6.4 times the peak ground acceleration at rock and soft sites, respectively. The peak elastic acceleration demands imposed on flexible nonstructural components in all floors, estimated using floor response spectra, might be four times larger than the maximum acceleration of the floor at the point of support of the component for buildings located in rock and soft soil. Comparison of results from the two approaches with the current seismic design provisions revealed that the peak acceleration demands and floor response spectra computed with the current 2017 Mexico City seismic design provisions are, in general, adequate.


Author(s):  
Satoru Kai ◽  
Tomoyoshi Watakabe ◽  
Naoaki Kaneko ◽  
Kunihiro Tochiki ◽  
Makoto Moriizumi ◽  
...  

The piping in a nuclear power plant is laid across multiple floors of a single building or two buildings, which are supported at many points. As the piping is excited by multiple-inputs from the supporting points during an earthquake, seismic response analysis by multiple excitations is needed to obtain the exact seismic response of the piping. However, few experiments involving such multiple excitation have been performed to verify the validity of multiple excitation analysis. Therefore, analysis of the seismic design of piping in Japan is performed by the enveloped Floor Response Spectrum (FRS), which covers all floor response spectra at all supporting points. The piping response estimated by enveloped FRS is conservative in most cases compared with the actual seismic response by multiple excitations. To perform rational seismic design and evaluation, it is important to investigate the seismic response by multiple excitations and to verify the validity of the analytical method by multiple excitation test. This paper reports the validation results of the multiple-excitation analysis of piping compared with the results of the multiple excitations shaking test using triple uni-axial shaking table and a 3-dimensional piping model (89.1mm diameter and 5.5mm thickness). Three directional moments from the analysis and the shaking test were compared on the validation. As the result, it is confirmed that the analysis by multiple time history excitation corresponds with the test result.


2010 ◽  
Vol 163-167 ◽  
pp. 443-453
Author(s):  
Wen Feng Liu ◽  
Xing Pan Fu

The seismic performance spectrum is a new kind of the response spectra which is formed according to the designated performance objectives. The performance objectives are changed according to the performance objective level and period of structure, and are different in the acceleration sensitive, velocity sensitive and displacement sensitive range in the seismic performance spectrum. The seismic performance spectrum formulas are derived, which demonstrate the mathematic relationship between the seismic demands of the different performance objective levels and the period of structure. The fitted formulas of the seismic performance spectra for seismic design are obtained due to statistical result of 1085 ground motion records. The new seismic performance spectra are shown in visual three-dimension figures which can represent the seismic demand, performance objective and period of structure in this paper. The philosophy of the seismic performance spectrum is analyzed which reveals the rules for estimating seismic demand of structure at the different performance objective levels. So the multi-objective performance-based seismic design is also proposed using the seismic performance spectrum.


2021 ◽  
Vol 2021 ◽  
pp. 1-18
Author(s):  
Beatrice Chichino ◽  
Simone Peloso ◽  
Davide Bolognini ◽  
Claudio Moroni ◽  
Daniele Perrone ◽  
...  

Seismic risk reduction of a building system, meant as primary building structure and nonstructural elements (NSEs) as a whole, must rely upon an adequate design of each of these two items. As far as NSEs are concerned, adequate seismic design means understanding of some basic principles and concepts that involve different actors, such as designers, manufacturers, installers, and directors of works. The current Italian Building Code, referred to as NTC18 hereinafter, defines each set of tasks and responsibilities in a sufficiently detailed manner, rendering now evident that achieving the desired performance level stems from a jointed contribution of all actors involved. Bearing in mind that seismic design is nothing else than proportioning properly seismic demand, in terms of acceleration and/or displacement, and the corresponding capacity, this paper gives a synthetic and informative overview on how to evaluate these two parameters. To shed some light on this, the concept of acceleration floor response spectrum (AFRS) is firstly brought in, along with basics of building structure-NSEs interaction, and is then deepened by means of calculation methods. Both the most rigorous method based on nonlinear dynamic simulations and the simplified analytical formulations provided by the NTC18 are briefly discussed and reviewed, trying to make them clearer even to readers with no structural/earthquake engineering background because, as a matter of fact, NSEs are often selected by architects and/or mechanical or electrical engineers. Lastly, a simple case study, representative of a European code-compliant five-storey masonry-infilled reinforced concrete frame building, is presented to examine differences between numerical and analytical AFRS and to quantify accuracy of different NTC18 procedures.


Author(s):  
Xiu-yun Zhu ◽  
Rong Pan

The traditional soil dynamic impedance models, recommended by the main international seismic design codes of the nuclear power plant (NPP), are only expressed by a single parallel connection system of spring and dashpot which can not reflect the dynamic stiffness varying with excitation frequencies, and also can not simulate the cases of non-homogeneous site conditions. With the recent development of soil-structure interaction (SSI) analysis, based on the damping-solvent extraction method (DSEM) and the lumped parameter models recommended by seismic design codes of ASCE4-98,RCCG which are all applicable to the homogeneous site and also massless foundation model and viscous-spring artificial boundary model of especially fit for the numerical simulation of non-homogeneous site, comparative study of both the direct method and sub-structure method is carried out in this paper. Finally, by taking the analysis of floor response spectra (FRS) for a certain CPR1000 reactor building as an example, comparative analyses of homogeneous and layered site conditions using various soil dynamic numerical models above-mentioned are performed. In addition, in order to validate the accuracy, the calculated results are compared to that of SASSI program. The results show that FRS in the horizontal direction are good agreement regardless for the homogeneous and layered site conditions, the shapes of FRS in the vertical direction change obviously in the homogeneous site condition. This paper provides some guidance and reference in the aspect of evaluation the seismic suitability for the site of nuclear power plant (NPP).


Author(s):  
Tomoyoshi Watakabe ◽  
Naoaki Kaneko ◽  
Shigekazu Aida ◽  
Akihito Otani ◽  
Makoto Moriizumi ◽  
...  

The piping in a nuclear power plant is laid across multiple floors of a single building or two buildings, which are supported at many points. As the piping is excited by multiple inputs from the supporting points during an earthquake, seismic response analysis by multiple excitations is needed to obtain the exact seismic response of the piping. However, few experiments involving such multiple excitations have been performed to verify the validity of multiple excitation analysis. Therefore, analysis of the seismic design of piping in Japan is performed by the enveloped Floor Response Spectrum (FRS), which covers all floor response spectra at all supporting points. The piping response estimated by enveloped FRS is conservative in most cases compared with the actual seismic response by multiple excitations. To perform rational seismic design and evaluation, it is important to investigate the seismic response by multiple excitations and verify the validity of the analysis method by multiple-excitation test. This paper reports on the result of the shaking test using triple uni-axial shaking tables and a 3-dimensional piping model (89.1mm in diameter and 5.5mm thickness). The piping model was fixed to three shaking tables, meaning three. Different inputs were possible. By the shaking test, dynamic behavior under multiple excitations was confirmed, and data to verify multiple-excitation analysis was obtained.


Author(s):  
Nikita Chernukha

The article is about nuclear power plant (NPP) safety analysis in case of aircraft crash. Specifically, the article considers the following problems: inclusion of aircraft crash into NPP design bases regarding calculation of frequency of an aircraft crash into NPP; aspects of justification of loads on NPP structures, systems and components (SSCs) caused by mechanical action of a primary missile – aircraft fuselage impact. Probabilistic characteristics of such random parameters as frequency of aircraft crash and direction of aircraft trajectory are determined by the results of analysis of world statistics of aviation accidents. Method of calculation of aircraft crash frequency on structures, buildings and NPP as a whole is presented. It takes into account options of accidental and intentional aircraft crashes and various aircraft approach scenarios. Procedure of probabilistic justification of loads on civil structures under aircraft impact is described. The loads are specified so as not to exceed allowable value of failure probability of NPP as a whole. Calculation of failure frequency of civil structures of existing NPP is given as an example to show analysis in case of a crash of an aircraft heavier than considered in NPP design. Procedure of probabilistic justification of dynamic loads on NPP equipment in case of aircraft impact is described. Method of floor response spectra (FRS) calculation with the required non-exceedance probability is given. Probabilistically justified loads in case of intentional aircraft impact (act of terrorism) are also considered. Additionally it is presented how internal forces calculated with the use of FRS with the required non-exceedance probability can be summed to provide analysis of subsystems.