Point‐of‐care ultrasound assessment with handheld ultrasound device attached to cell phone

Author(s):  
Julio C. Sauza‐Sosa ◽  
Karen Arratia‐Carlin ◽  
Jorge Fernandez‐Tapia
2019 ◽  
Vol 41 (03) ◽  
pp. 308-316 ◽  
Author(s):  
Eckhart Fröhlich ◽  
Katharina Beller ◽  
Reinhold Muller ◽  
Maria Herrmann ◽  
Ines Debove ◽  
...  

Abstract Purpose The aim of the current study was to evaluate point of care ultrasound (POCUS) in geriatric patients by echoscopy using a handheld ultrasound device (HHUSD, VScan) at bedside in comparison to a high-end ultrasound system (HEUS) as the gold standard. Materials and Methods Prospective observational study with a total of 112 geriatric patients. The ultrasound examinations were independently performed by two experienced blinded examiners with a portable handheld device and a high-end ultrasound device. The findings were compared with respect to diagnostic findings and therapeutic implications. Results The main indications for the ultrasound examinations were dyspnea (44.6 %), fall (frailty) (24.1 %) and fever (21.4 %). The most frequently found diagnoses were cystic lesions 32.1 % (35/109), hepatic vein congestion 19.3 % (21/109) and ascites 13.6 % (15/110). HHUSD delivered 13 false-negative findings in the abdomen resulting in an “overall sensitivity” of 89.5 %. The respective “overall specificity” was 99.6 % (7 false-positive diagnoses). HHUSD (versus HEUS data) resulted in 13.6 % (17.3 %) diagnostically relevant procedures in the abdomen and 0.9 % (0.9 %) in the thorax. Without HHUSD (HEUS) 95.7 % (100 %) of important pathological findings would have been missed. Conclusion The small HHUSD tool improves clinical decision-making in immobile geriatric patients at the point of care (geriatric ward). In most cases, HHUSD allows sufficiently accurate yes/no diagnoses already at the bedside, thereby clarifying the leading symptoms for early clinical decision-making.


2018 ◽  
Vol 37 (11) ◽  
pp. 2517-2525 ◽  
Author(s):  
Andrew Smith ◽  
Reuben Addison ◽  
Peter Rogers ◽  
Jordan Stone-McLean ◽  
Sarah Boyd ◽  
...  

CJEM ◽  
2015 ◽  
Vol 18 (5) ◽  
pp. 391-394
Author(s):  
Michael Romano ◽  
Tomislav Jelic ◽  
Jordan Chenkin

AbstractThere is evidence to suggest that point-of-care ultrasound assessment of the lungs has a higher sensitivity and specificity than chest radiography for the diagnosis of pneumonia. It is unknown if the same is true for pneumonia complications. We present and discuss the case of a 61-year-old woman who presented to the emergency department with confusion, decreased level of consciousness, and signs of sepsis. A chest x-ray revealed a right sided infiltrate. An ultrasound of the patient’s lungs was performed, and revealed a complex loculated fluid collection consistent with an empyema. A chest CT confirmed the diagnosis, and immediate percutaneous drainage was performed.


2015 ◽  
Vol 44 (2) ◽  
pp. 92-99 ◽  
Author(s):  
Benjamin K. Johnson ◽  
David M. Tierney ◽  
Terry K. Rosborough ◽  
Kevin M. Harris ◽  
Marc C. Newell

2020 ◽  
Vol 4 (2) ◽  
pp. 222-224
Author(s):  
Ashley Rider ◽  
Andrea Dreyfuss ◽  
Roberto Inga

Ebstein’s anomaly is a congenital heart defect that when left untreated can lead to unique physical exam and ultrasound findings. This case describes a patient who presented with dyspnea and was found to have cyanosis, clubbing, and dilation of right-sided chambers on point-of-care ultrasound. The series of images highlights findings in late-stage Ebstein’s anomaly and serves as a springboard for the discussion of the pathophysiology, diagnosis, and treatment of this rare congenital heart disease.


2020 ◽  
Vol 12 (1) ◽  
Author(s):  
Samuel L. Burleson ◽  
Jonathan F. Swanson ◽  
Erin F. Shufflebarger ◽  
Douglas W. Wallace ◽  
Matthew A. Heimann ◽  
...  

Abstract Background Many point-of-care ultrasound devices are now “pocket-sized” or handheld, allowing easy transport during travel and facilitating use in crowded spaces or in austere low-resource settings. Concerns remain about their durability, image quality, and clinical utility in those environments. Method Five emergency physicians with training in point-of-care ultrasound employed the Butterfly iQ, a novel handheld ultrasound device, in routine clinical care in a busy, high-acuity African emergency department over a period of 10 weeks. We retrospectively evaluated the performance of the Butterfly iQ from the perspectives of both the clinicians using the device and expert ultrasound faculty reviewing the images. Results We found advantages of the Butterfly iQ in a high-acuity African emergency department include its use of a single probe for multiple functions, small size, ease of transport, relatively low cost, and good image quality in most functions. Disadvantages include large probe footprint, lower, though still adequate, cardiac imaging quality, frequent overheating, and reliance on internet-based cloud storage, but these were surmountable. We also report a wide variety of patient presentations, pathology, and procedures to which the device was used. Conclusion We conclude the Butterfly iQ is an effective, though imperfect, point-of-care ultrasound device in a low-resource emergency setting. We will continue to employ the device in clinical emergency care and teaching in this setting.


Author(s):  
E.M. Jung ◽  
J. Dinkel ◽  
N. Verloh ◽  
M. Brandenstein ◽  
C. Stroszczynski ◽  
...  

AIM: To evaluate the diagnostic reliability of a new generation wireless point-of care ultrasound device for abdominal and thoracic findings. MATERIAL AND METHODS: 40 patients (16 females, 24 males 19 –80 years, on average 56.1 years) were scanned by an experienced examiner using the new wireless Vscan Air device for abdominal and thoracic findings. The probe frequencies were 2–5 MHz (convex probe) and 3–12 MHz for the linear probe. As a reference standard, all patients were also examined using high-end ultrasound (LOGIQ E9/10). Results were interpreted independently by two examiners in consensus, also with regard to the image quality (0–4, from not assessable = 0, to excellent 4). RESULTS: In all 40 patients (100%) examination with conventional high-end ultrasound and the Vscan Air ultrasound device was feasible. Sensitivity, specificity, positive and negative predictive value for the diagnosis of abdominal and thoracic findings were 63.3%, 100%, 100%, and 40%, respectively. Most main diagnostic findings were detected using the mobile device compared to the high-end ultrasound. Limitations were found regarding characterization and classification of hepatic and renal tumorous lesions. Image quality revealed mostly minor diagnostic limitations for the mobile device, mean 2.9 (SD –0.300) and was excellent or with only minor diagnostic limitations for conventional high-end ultrasound, mean 3.25 (SD –0.438). CONCLUSION: Due to its easy application and its high diagnostic reliability, point-of-care ultrasound systems of the latest generation represent a valuable imaging method for the primary assessment of abdominal and thoracic findings, especially in patients on intensive care units or in emergency situations.


Sign in / Sign up

Export Citation Format

Share Document