Fabrication of Au nanorod-coated Fe3 O4 microspheres as SERS substrate for pesticide analysis by near-infrared excitation

2015 ◽  
Vol 46 (5) ◽  
pp. 470-475 ◽  
Author(s):  
Xianghu Tang ◽  
Ronglu Dong ◽  
Liangbao Yang ◽  
Jinhuai Liu
Small ◽  
2016 ◽  
Vol 12 (13) ◽  
pp. 1732-1743 ◽  
Author(s):  
Akshaya Bansal ◽  
Haichun Liu ◽  
Muthu Kumara Gnanasammandhan Jayakumar ◽  
Stefan Andersson-Engels ◽  
Yong Zhang

2012 ◽  
Vol 2012 ◽  
pp. 1-11 ◽  
Author(s):  
Timothy J. Johnson ◽  
Yin-Fong Su ◽  
Kristin H. Jarman ◽  
Brenda M. Kunkel ◽  
Jerome C. Birnbaum ◽  
...  

As Raman spectroscopy continues to evolve, questions arise as to the portability of Raman data: dispersive versus Fourier transform, wavelength calibration, intensity calibration, and in particular the frequency of the excitation laser. While concerns about fluorescence arise in the visible or ultraviolet, most modern (portable) systems use near-infrared excitation lasers, and many of these are relatively close in wavelength. We have investigated the possibility of porting reference data sets from one NIR wavelength system to another: We have constructed a reference library consisting of 145 spectra, including 20 explosives, as well as sundry other compounds and materials using a 1064 nm spectrometer. These data were used as a reference library to evaluate the same 145 compounds whose experimental spectra were recorded using a second 785 nm spectrometer. In 128 cases of 145 (or 88.3% including 20/20 for the explosives), the compounds were correctly identified with a mean “hit score” of 954 of 1000. Adding in criteria for when to declare a correct match versus when to declare uncertainty, the approach was able to correctly categorize 134 out of 145 spectra, giving a 92.4% accuracy. For the few that were incorrectly identified, either the matched spectra were spectroscopically similar to the target or the 785 nm signal was degraded due to fluorescence. The results indicate that imported data recorded at a different NIR wavelength can be successfully used as reference libraries, but key issues must be addressed: the reference data must be of equal or higher resolution than the resolution of the current sensor, the systems require rigorous wavelength calibration, and wavelength-dependent intensity response should be accounted for in the different systems.


2021 ◽  
Author(s):  
Yueshu Feng ◽  
Binyu Li ◽  
Yulin Huang

2019 ◽  
Vol 55 (10) ◽  
pp. 1450-1453 ◽  
Author(s):  
Chengkai Zhang ◽  
Yanqian Zhao ◽  
Dandan Li ◽  
Jiejie Liu ◽  
Heguo Han ◽  
...  

Two-photon active photosensitizers showed relatively strong intersystem crossing facilitating 1O2 generation and cell apoptosis with near-infrared excitation.


2019 ◽  
Vol 7 (46) ◽  
pp. 7306-7313 ◽  
Author(s):  
Jinhua Wu ◽  
Shanshan Du ◽  
Yuhua Wang

Rare-earth-based upconversion nanotechnology has recently shown great promise for photodynamic therapy (PDT).


2017 ◽  
Vol 5 (7) ◽  
pp. 1724-1729 ◽  
Author(s):  
D. Wawrzyńczyk

Synthesized penicillamine stabilized CdS tetrapods showed two-photon absorption in a wavelength range between 600 and 850 nm, and strong two-photon excited emission upon near infrared excitation. These water soluble colloidal, semiconducting nanoparticles show potential for applications in nonlinear bioimaging.