A simple liquid chromatography coupled with tandem mass spectrometry approach for the simultaneous quantification of thirteen compounds in rats following oral administration of raw and processed Fructus Xanthii : Application in a comparative pharmacokinetic study

2019 ◽  
Vol 42 (22) ◽  
pp. 3403-3412 ◽  
Author(s):  
Hai Jiang ◽  
Liu Yang ◽  
Xudong Xing ◽  
Meiling Yan ◽  
Xinyue Guo ◽  
...  
2018 ◽  
Vol 25 (4) ◽  
pp. 372-380 ◽  
Author(s):  
Sireesha Dodda ◽  
Ajitha Makula ◽  
Srinivasa R Polagani ◽  
Raj N Kandhagatla

A method for bioanalysis of pentoxifylline in human plasma was developed using liquid chromatography–tandem mass spectrometry, which is simple, specific, and sensitive. Pentoxifylline D5 was used as the internal standard. Employing only 100 µl of human plasma, processing was done with solid-phase extraction technique. The analyte and the internal standard were separated from endogenous components on Ace phenyl column using a mixture of 5 mM ammonium acetate buffer and high performance liquid chromatography grade acetonitrile (60:40, v/v) as mobile phase at a flow rate of 1 ml/min. The linearity of the method was in the range of 3–1200 ng/ml with r2 > 0.99. Positive ion MRM mode was used for the detection of the analyte and the internal standard. The method was validated as per the US Food and Drug Administration guidelines and the results were within the acceptance limits. The proposed method was applied for comparative pharmacokinetic study of pentoxifylline after oral administration of 400 and 600 mg tablets to South Indian male subjects under fed conditions.


Molecules ◽  
2018 ◽  
Vol 23 (8) ◽  
pp. 1927 ◽  
Author(s):  
Hongrui Dong ◽  
Guanyun Yan ◽  
Zhibin Wang ◽  
Chengcui Wu ◽  
Binbin Cui ◽  
...  

A rapid and sensitive Ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the simultaneous determination of fourteen alkaloids in beagle dog plasma after a single oral dose of the Corydalis bungeana Turcz (C. bungeana) extract selected bifendate as the internal standard (IS). The plasma samples were preprocessed by liquid-liquid extraction (LLE) with aether before separation on an Agilent SB-C18 column (1.8 µm, 150 × 2.1 mm) using a gradient elution program. The mobile phase consists of 0.2% acetic acid and acetonitrile at the flow rate of 0.3 mL/min. In the positive ion mode, the analytes were detected by multiple reaction monitoring (MRM). The results indicated that calibration curves for fourteen analytes have good linearity (R2 = 0.9904). The lower limits of quantification (LLOQ) of fourteen alkaloids and IS were all over 4.87 ng/mL and the matrix effects ranged from 94.08% to 102.76%. The mean extraction recoveries of Quality control samples at low (LQC), medium (MQC) and high (HQC) and IS were all more than 78.03%. The intra- and inter-day precision (R.S.D.%) also met the criterion, at the same time the deviation of assay accuracies (R.E) ranged from −13.70% to 14.40%. The Tmax values of fourteen alkaloids were no more than 1 h. The range of Cmax was from 74.16 ± 8.71 to 2256 ± 255.9 ng/mL. The assay was validated in the light of the regulatory bioanalytical guidelines and proved acceptable, which was successfully applied to a pharmacokinetic study of these compounds in beagle dogs after oral administration of Corydalis bungeana Turcz extract.


Sign in / Sign up

Export Citation Format

Share Document