scholarly journals Ultraspecific and Highly Sensitive Nucleic Acid Detection by Integrating a DNA Catalytic Network with a Label-Free Microcavity

Small ◽  
2014 ◽  
Vol 10 (10) ◽  
pp. 2067-2076 ◽  
Author(s):  
Yuqiang Wu ◽  
David Yu Zhang ◽  
Peng Yin ◽  
Frank Vollmer
Author(s):  
Bailin Zhang ◽  
Shatha Dallo ◽  
Ralph Peterson ◽  
Syed Hussain ◽  
Tao Weitao ◽  
...  

2019 ◽  
Vol 91 (16) ◽  
pp. 10870-10878 ◽  
Author(s):  
Jianyu Hu ◽  
Min Jiang ◽  
Rui Liu ◽  
Yi Lv

Micromachines ◽  
2020 ◽  
Vol 11 (5) ◽  
pp. 526 ◽  
Author(s):  
Yafeng Huang ◽  
Lulu Zhang ◽  
Hao Zhang ◽  
Yichen Li ◽  
Luyao Liu ◽  
...  

Nucleic acid detection is of great significance in clinical diagnosis, environmental monitoring and food safety. Compared with the traditional nucleic acid amplification detection method, surface plasmon resonance (SPR) sensing technology has the advantages of being label-free, having simple operation, and providing real-time detection. However, the angle scanning system in many SPR angle modulation detection applications usually requires a high-resolution stepper motor and complex mechanical structure to adjust the angle. In this paper, a portable multi-angle scanning SPR sensor was designed. The sensor only uses one stepping motor to rotate a belt, and the belt pulls the mechanical linkages of incident light and reflected light to move in opposite directions for achieving the SPR angle scanning mode that keeps the incident angle and reflected angle equal. The sensor has an angle scanning accuracy of 0.002°, response sensitivity of 3.72 × 10−6 RIU (refractive index unit), and an angle scanning range of 30°–74°. The overall size of the system is only 480 mm × 150 mm × 180 mm. The portable SPR sensor was used to detect nucleic acid hybridization on a gold film chip modified with bovine serum albumin (BSA). The result revealed that the sensor had high sensitivity and fast response, and could successfully accomplish the hybridization detection of target DNA solution of 0.01 μmol/mL.


2020 ◽  
Author(s):  
Marijn van den Brink ◽  
Sebastian T. Tandar ◽  
Tim A. P. van den Akker ◽  
Sinisha Jovikj ◽  
Violette Defourt ◽  
...  

AbstractIn the last three decades, there have been recurring outbreaks of infectious diseases, brought to light with the recent outbreak of coronavirus disease 2019 (COVID-19). Attempts to effectively contain the spread of infectious diseases have been hampered by the lack of rapidly adaptable, accurate, and accessible point-of-care diagnostic testing. In this study, we present a novel design of a label-free DNAzyme-based detection method called Rapidemic. This assay combines recombinase polymerase amplification (RPA) with linear strand-displacement amplification (LSDA) and guanine-quadruplex (GQ) DNAzyme-catalysed colour-changing reaction. The colorimetry basis of the signal readout omits the need for extensive instrumentation. Moreover, the primer-based sequence detection of RPA gives Rapidemic a potential to be rapidly adapted to target a new sequence. As a proof of concept, we developed the assay to detect isolated genomic DNA of Saccharomyces cerevisiae. The use of low-pH buffers and the optimization of the dilution rates from each preceding reaction to the next showed to be successful strategies to enable visible detection with this method. These findings demonstrate for the first time that a label-free DNAzyme-based detection method can be coupled to RPA and LSDA for nucleic acid detection.


2021 ◽  
pp. 113292
Author(s):  
Tao Li ◽  
Rui Hu ◽  
Jianbo Xia ◽  
Zhichen Xu ◽  
Dongjuan Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document