scholarly journals Experimental study of earthquake input energy of low‐frequency structures equipped with a passive rate‐independent damping device

Author(s):  
Wei Liu ◽  
Kohju Ikago
Sensors ◽  
2018 ◽  
Vol 18 (11) ◽  
pp. 3721 ◽  
Author(s):  
Usman Rashid ◽  
Imran Niazi ◽  
Nada Signal ◽  
Denise Taylor

Texas Instruments ADS1299 is an attractive choice for low cost electroencephalography (EEG) devices owing to its low power consumption and low input referred noise. To date, there have been no rigorous evaluations of its performance. In this EEG experimental study we evaluated the performance of the ADS1299 against a high quality laboratory-based system. Two self-paced lower limb motor tasks were performed by 22 healthy participants. Recorded power across delta, theta, alpha, and beta EEG bands, the power ratio across the motor tasks, pre-movement noise, and signal-to-noise ratio were obtained for evaluation. The amplitude and time of the negative peak in the movement-related cortical potentials (MRCPs) extracted from the EEG data were also obtained. Using linear mixed models, no statistically significant differences (p > 0.05) were found in any of these measures across the two systems. These findings were further supported by evaluation of cosine similarity, waveform differences, and topographic maps. There were statistically significant differences in MRCPs across the motor tasks in both systems. We conclude that the performance of the ADS1299 in combination with wet Ag/AgCl electrodes is analogous to that of a laboratory-based system in a low frequency (<40 Hz) EEG recording.


2013 ◽  
Vol 12 (1) ◽  
pp. 243-250
Author(s):  
Błażej Meronk ◽  
Krzysztof Wilde

The paper presents the experimental study on the inter-modulation method for the diagnostics of concrete elements. The tests were conducted on a concrete plate subjected to ultrasonic waves and low frequency vibrations. The nonlinear acoustic effects, recorded in the experiments, made it possible to detect the presence of damaged zones. Further studies are necessary to establish the relation between the sidebanes of frequency spectra and the size of the damaged zone.


1995 ◽  
Vol 407 ◽  
Author(s):  
B. Rufflé ◽  
S. Beaufils ◽  
Y. Délugeard ◽  
G. Coddens ◽  
J. Etrillard ◽  
...  

ABSTRACTNew experimental results obtained with various techniques on a less-studied glass-forming system are presented. At low frequency, a secondary βslow-process, decoupled from the viscous flow, is observed by 3 1P NMR. Raman scattering spectra and coherent neutron scattering spectra has been obtained in wide frequency and temperature ranges showing the same qualitative features for the Boson peak while the quasielastic contribution seems to differ markedly.


1982 ◽  
Vol 27 (3-4) ◽  
pp. 103-111 ◽  
Author(s):  
RYUICHI MATSUMOTO ◽  
TSUYOSHI NAKAJIMA ◽  
KYOJI KIMOTO ◽  
SUSUMU NO DA ◽  
SHODO MAEDA

2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Jianlei Liu ◽  
Meng Ma ◽  
Flavio Stochino

The bearing capacity evaluation of bridge substructures is difficult as the static loading test (SLT) cannot be employed for the bridges in services. As a type of dynamic nondestructive test technique, the dynamic transient response method (TRM) could be employed to estimate the vertical bearing capacity when the relationship between static stiffness and dynamic stiffness is known. The TRM is usually employed to evaluate single piles. For the pier-cap-pile system, its applicability should be investigated. In the present study, a novel full-scale experimental study, including both TRM test and SLT, was performed on an abandoned bridge pier with grouped pile foundation. The test included three steps: firstly, testing the intact pier-cap-pile system; then, cutting off the pier and testing the cap-pile system; finally, cutting off the cap and testing the single pile. The TRM test was repeatedly performed in the above three steps, whereas the SLT was only performed on the cap-pile system. Based on the experimental results, the ratio of dynamic and static stiffness of the cap-pile system was obtained. The results show that (1) in the low-frequency range (between 10 and 30 Hz in this study), the dynamic stiffness of the whole system is approximately four times of that of a single pile; (2) the ratio of dynamic and static stiffness of the cap-pile system tested in the study is approximately 1.74, which was similar to other tested values of a single pile; (3) to evaluate the capacity of similar cap-pile system and with similar soil layer conditions by TRM, the value of Kd/Ks tested in the study can be used as a reference.


Sign in / Sign up

Export Citation Format

Share Document