Aortic Pathology: AAA, Dissection, and Traumatic Transection

Author(s):  
David G. Neschis ◽  
Marshall E. Benjamin ◽  
Justin K. Nelms ◽  
William R. Flinn
Author(s):  
Valeria Silvestri ◽  
Gregorio Egidio Recchia
Keyword(s):  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Karl C. König ◽  
Harald Lahm ◽  
Martina Dreßen ◽  
Stefanie A. Doppler ◽  
Stefan Eichhorn ◽  
...  

AbstractAcute type A aortic dissection (ATAAD) constitutes a life-threatening aortic pathology with significant morbidity and mortality. Without surgical intervention the usual mortality rate averages between 1 and 2% per hour. Thus, an early diagnosis of ATAAD is of pivotal importance to direct the affected patients to the appropriate treatment. Preceding tests to find an appropriate biomarker showed among others an increased aggrecan (ACAN) mRNA expression in aortic tissue of ATAAD patients. As a consequence, we investigated whether ACAN is a potential biomarker for diagnosing ATAAD. Mean ACAN protein concentration showed a significantly higher plasma concentration in ATAAD patients (38.59 ng/mL, n = 33) compared to plasma of patients with thoracic aortic aneurysms (4.45 ng/mL, n = 13), patients with myocardial infarction (11.77 ng/mL, n = 18) and healthy volunteers (8.05 ng/mL, n = 12). Cardiac enzymes like creatine kinase MB and cardiac troponin T showed no correlation with ACAN levels in ATAAD patients. Receiver-operator characteristics (ROC) curve analysis for ATAAD patients versus control subjects an optimum discrimination limit of ACAN plasma levels at 14.3 ng/mL with a corresponding sensitivity of 97% and specificity of 81%. According to our findings ACAN is a reliable potential biomarker in plasma samples to detect ATAAD with high sensitivity and specificity.


2011 ◽  
Vol 53 (6) ◽  
pp. 42S-44S
Author(s):  
Muhammad Aftab ◽  
Vijay Kamath ◽  
Rajeev Gupta ◽  
Frank Manetta ◽  
Alan Hartman ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-3
Author(s):  
Sisira Sran ◽  
Manpreet Sran ◽  
Nicole Ferguson ◽  
Amgad N. Makaryus

Ascending aortic aneurysms involving the proximal aortic arch, arising anywhere from the aortic valve to the innominate artery, represent various problems in which open surgery is generally required. Surgical options include excision of the aortic pathology or wrapping the aneurysm shell with an aortic Dacron graft. Intervention using the latter method can lead to extravasation of blood along the suture lines resulting in continuous bleeding within the periprosthetic space. The Cabrol technique was developed as a method for decompression of postoperative leaks by the formation of a conduit system from the periprosthetic space to the right atrium. The coronary ostia are anastomosed to a second graft in an end-to-end fashion, which is then anastomosed to the ascending aortic conduit side to side. The native aorta is then sewn around the prosthesis, hereby creating a shunt to drain anastomotic leakage. This shunt reduces postsurgical risk of pseudoaneurysm formation and normally closes a few days following surgery. We discuss the case of a patient who underwent Cabrol’s variation and six months later was demonstrated to have a patent shunt.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
C Ferrera Duran ◽  
I Vilacosta ◽  
J Perez-Villacastin ◽  
P Busca ◽  
A Carrero ◽  
...  

Abstract Background Expediting life-saving care for patients with acute aortic syndrome (AAS) through multi-disciplinary code protocols is a potential method to improve outcomes. Other code protocols for cardiovascular emergencies, such as ST-elevation myocardial infarction and stroke have shown excellent results. Aim To examine the implementation and preliminary results of a code protocol “Aorta Code” for patients with AAS in a healthcare framework of a 4-hospital network in our city by reviewing the number of patients detected, patient's transference time, aortic surgery and patient's outcome during a trial period of 10 months (April 2019-January 2020). A comparison with a previous 2-year period with standard of care management of AAS was performed. Methods “Aorta Code” uses a specific diagnostic algorithm to improve detection of patients with AAS at the emergency room, facilitates their quick transfer to the referral hospital by activating a paging system, and places acute cardiovascular care unit, operating room and surgeons specialized in aortic pathology on standby. Results Compared to a previous 2-year period (2017–2018) (group I), the current implementation of “Aorta Code” in a period of 10 months (group II) in our 4-hospital network involving the healthcare of 1.100000 inhabitants resulted in the detection of more patients with AAS (group-I: n=18 patients (0.8 patients/month), group-II: n=19 patients (1.9 patients/month); p=0.013). AAS detection in secondary hospitals importantly increased (33.3% vs 63.8%, p=0.07). The “Aorta Code” achieved a significant decrease in patient's transference time to referral hospital (group-I: median 259 min (IQR 150–1911), group-II: median 129 min (IQR 95.5–167.25); p=0.035). There was a marked reduction in the number of surgeons involved in the “Aorta Code” (group-I= 7 cardiac, 6 vascular, group-II= 2 cardiac, 2 vascular). Thirty-day mortality was lower in group-II in the whole AAS cohort (group-I= 22.2%, group-II= 12.5%; p=0.660) and in type A AAS (28.6% vs 18.2%, p=0.661). Misdiagnosis rate (false-calls): 11 patients (7 of them with non-acute aortic disease). Conclusion “Aorta Code” facilitates detecting patients with AAS at the emergency room, speeds them to the referral hospital center, allows patients to be treated by surgeons specialized in aortic surgery and improves patient's outcome. Further prospective studies examining the utility of “Aorta Code” are warranted. Funding Acknowledgement Type of funding source: None


Sign in / Sign up

Export Citation Format

Share Document