Prolonged and Continuous Measurement of Kidney Oxygenation in Conscious Rats

Author(s):  
Maarten P. Koeners ◽  
Connie P. C. Ow ◽  
David M. Russell ◽  
Roger G. Evans ◽  
Simon C. Malpas
1988 ◽  
Vol 255 (5) ◽  
pp. H1206-H1210 ◽  
Author(s):  
R. Veelken ◽  
P. Schelling ◽  
T. Unger

The continuous measurement of cardiac output in conscious rats is difficult. Previously, Doppler flow probes have been applied to the ascending aorta by means of silicone cuffs. The placement of these cuffs can conceivably introduce errors engendered by the destruction of nerve fibers that are important in cardiac autonomic innervation. We report a novel method of Doppler flow-probe attachment directly to the ascending aorta by means of a polyacrylic cement. When we compared the response with baroreceptor activation with methoxamine and nitroprusside in conscious rats equipped either with probes attached via cuffs or directly via cement, we observed that animals equipped with cuffs failed to give the expected cardiac output and heart rate responses after nitroprusside administration. In contrast, animals that had their probes attached with cement displayed the expected responses. The data not only show that probes applied with cement give a result superior to probes attached with cuffs but also verify the suspicion that the ascending aorta is associated with nerve fibers that are important in mediating baroreceptor responses.


1970 ◽  
Vol 13 (1) ◽  
pp. 65-73 ◽  
Author(s):  
Mary Mira

Listening, a significant dimension of the behavior of hearing-impaired children, may be measured directly by recording childrens' responses to obtain audio narrations programmed via a conjugate reinforcement system. Twelve hearing-impaired, school-aged children responded in varying ways to the opportunity to listen. Direct and continuous measurement of listening has relevance for evaluation of remediation methods and for discovery of variables potentially related to listening.


1998 ◽  
Vol 5 (1) ◽  
pp. 146A-146A
Author(s):  
L DANIELSON ◽  
O SHERWOOD ◽  
K CONRAD
Keyword(s):  

2013 ◽  
pp. 1-1
Author(s):  
Ragini C Bhake ◽  
Jack A Leendertz ◽  
Astrid C E Linthorst ◽  
Stafford L Lightman

1997 ◽  
Vol 36 (4) ◽  
pp. 307-312
Author(s):  
Michael R. Rasmussen ◽  
Torben Larsen

An on-line settling column for measuring the dynamic variations of settling velocity of activated sludge has been developed. The settling column is automatic and self-cleansing insuring continuous and reliable measurements. The settling column was tested on sludge from a batch reactor where sucrose was added as an impulse to activated sludge. The continuous measurement of settling velocity revealed a highly dynamic response after the sucrose was added. The results were verified with simultaneous measurement of the initial settling rate. A 200 hour experiment showed variations in settling velocity, which was not apparent in the DSVI (Diluted Sludge Volume Index).


Sign in / Sign up

Export Citation Format

Share Document