Sustainable Alternative Water Sources Use for Lowering Cost Pressure on Drinking Water and Volume Reduction—Technical and Profitable Feasibility

Author(s):  
Cassio Faé ◽  
Lucien Akabassi ◽  
Adriana M. Nicolau Korres ◽  
Jacqueline R. Bringhenti ◽  
Sheila Souza da Silva Ribeiro
2017 ◽  
Vol 109 ◽  
pp. 18-25 ◽  
Author(s):  
Joan Oppenheimer ◽  
Allegra Da Silva ◽  
Zita L.T. Yu ◽  
Mark Hanna ◽  
Ken Susilo

Author(s):  
Katrina Wong ◽  
BCIT School of Health Sciences, Environmental Health ◽  
Helen Heacock ◽  
Frederick Shaw

  Background: One of the most frequent complaints to water distribution systems is the taste and odor of chlorine in consumer tap water. Chlorine is a common disinfectant used to inactivate and breakdown microbes and other contaminants. However, excess chlorine can result in an unpalatable chlorinous taste and odor. When water taste becomes too objectionable, consumers may search for alternative water sources, such as raw, untreated water that does not contain chemical additives. Raw, untreated water contains various contaminants, including disease-causing pathogens. To encourage consumers to drink treated tap water, and prevent disease, this study evaluated and compared the effectiveness of off-gassing, boiling and filtration as dechlorination methods for consumers to perform on their tap water. Method: Hach Method 8021 was performed to collect and analyse water samples following treatment with Off-gassing, Boiling and Filtration. Water samples were collected from BCIT SW1-1230. The Hach Pocket Colorimeter ™ II determined the free chlorine concentration of the water samples, and compared to a sample of untreated chlorinated tap water to see which method reduced chlorine concentrations the most. Results: Mean concentration of chlorine following off-gassing was determined to be 0.51 ppm, 0.24 ppm following boiling, and 0.55 ppm following filtration. It was determined that the boiling method was statistically significantly different from the mean values of chlorine concentration from the other two methods, as shown by the Kruskal-wallis test (P=0.000), and therefore was the most effective in dechlorinating tap water samples. This was further confirmed by the Scheffe’s Mutliple-Comparison Test and eyeball test. Conclusion: Based on the results, boiling water is the most effective method to dechlorinate potable tap water for consumer acceptability. The free chlorine levels found post-boiling were also found to be below the WHO’s threshold for tasting and smelling chlorine in drinking water (0.3 ppm), and above WHO’s minimum required 0.2 ppm chlorine residual. Therefore, drinking water following boiling will be safe for consumption, as well as free of chlorinous taste and smell. Public Health professionals can safely advise consumers of an effective method to encourage treated tap water consumption, and to discourage finding alternative water sources.  


2012 ◽  
Vol 437 ◽  
pp. 245-254 ◽  
Author(s):  
Treavor H. Boyer ◽  
Christine Overdevest ◽  
Lisa Christiansen ◽  
Stephanie K.L. Ishii

2010 ◽  
Vol 10 (6) ◽  
pp. 969-977 ◽  
Author(s):  
S. Cook ◽  
A. Sharma ◽  
D. Batten ◽  
S. Burn

This paper presents a framework for the matching industry clusters to appropriate alternative water sources using an eco-industrial approach. Alternative water sources are increasingly being considered in new industrial developments to reduce demand on potable supply and improve sustainability performance. The suitability of alternative water sources for industrial development is influenced both by the demand profile of the industrial tenants and the limitations and opportunities presented by the local environment. This paper demonstrates an approach that integrates the principals of industrial ecology for considering the feasibility of alternative water services in a new industrial estate. The application of industrial ecology principles takes a site specific approach that considers the opportunities and limitations offered by the local environment and existing regional industries in moving towards sustainable water services. Industrial ecology facilitates opportunities for planning symbiosis between industries through by-product exchange, water cascading and cooperative infrastructure. The framework was applied to a new industrial development in Melbourne, Australia; with the assessment of alternative water sources part of a larger project that had the purpose of identifying regional by-product synergies based on materials, energy and water exchanges between businesses. The feasibility assessment detailed demonstrates that suitability of alternative water sources varies depending on the industry water demand profile. The paper demonstrates that the application of industrial ecology principles can be used to consider the feasibility of alternative water sources based on the regional context and the demand profile of industries locating to an eco-industrial park.